Features | Replacing the RAID Controller | ||
|
|
|
|
Jum- | Type | Description |
|
pers |
|
|
|
|
|
|
|
J9 | I 2C connector |
| |
|
| Used for enclosure management. |
|
|
| Reserved for internal use |
|
|
|
|
|
J10 | Write Pending Indication |
| |
| LED | Connector for enclosure LED. |
|
|
| When lit, it indicates the onboard cache |
|
|
| contains data and a write from the cache |
|
|
| to the hard drives is pending. Optional. |
|
|
|
|
|
J11 | x4 SAS ports 0 - 3 | SFF 8484 x4 connector for connection to |
|
|
| physical drives and expanders. |
|
|
|
|
|
J12 | GND connector | Reserved for internal use |
|
|
|
|
|
J13 | GND connector | Reserved for internal use |
|
|
|
|
|
J14 | GND connector | Reserved for internal use |
|
|
|
|
|
J15 | I 2C connector |
| |
|
| Used for enclosure management. |
|
|
| Reserved for internal use |
|
|
|
|
|
J18 | SMBUS header for |
| |
| enclosure management | Used for enclosure management. |
|
|
| Reserved for internal use |
|
|
|
|
|
Table 2: Jumpers and Connectors |
|
|
Step 4 Remove the RAID SAS controller from the Mainboard
Remove the PCI card hold down latches that fix the RAID SAS controller to the computer chassis.
Remove the RAID SAS controller from the PCI Express slot on the motherboard (see your mainboard guide for information about the PCI Express slot).
D2630 (RX600 S3) SAS | 25 |