Fujitsu MBB2147RC, MBB2073RC manual Tests, Test flowchart

Page 74

Diagnostics and Maintenance

6.2.5Tests

This HDD can be tested in the following ways:

Initial seek operation check (See Subsection 6.3.1)

Operation test (See Subsection 6.3.2)

Diagnostic test (See Subsection 6.3.3)

Figure 6.1 shows the flow of these tests.

Start

Start self-test by turning the power on

 

 

No

 

 

Test results OK?

Check host system

 

 

 

 

 

 

 

 

(Table 6.2)

 

 

Yes

 

 

 

 

 

 

 

 

 

No

 

 

 

 

 

Execute an operation

 

 

 

Host system

 

 

 

 

 

 

 

normal?

 

test using a host

 

 

 

 

computer or test

 

 

 

Yes

 

equipment

 

 

 

 

 

 

 

 

 

Replaced or repair

 

 

 

No

 

 

HDD

 

Test results OK?

 

 

 

 

 

 

 

 

 

 

HDD

No

 

 

 

 

 

 

 

 

 

Yes

 

 

 

normal?

 

 

 

 

 

 

 

 

 

 

 

Yes

 

Continue operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Execute diagnostic

 

 

 

 

 

 

 

 

 

 

 

 

test using a host

 

 

 

 

 

 

computer or test

 

 

 

 

 

 

equipment

 

 

 

 

 

 

Test results OK?

No

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

Test using voltage or

 

 

 

 

 

 

temperature stress

 

 

 

 

 

 

Test results OK?

No

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

Figure 6.1 Test flowchart

Analyze system-related error

Analyze HDD error (Table 6.3)

70

C141-E257

Image 74
Contents MBB2147RC MBB2073RC Hard Disk Drives Product Manual For Safe Operation Revision Record Related Standards Preface Overview of ManualPreface Conventions for Alert MessagesImportant Alert Items Important Alert MessagesImportant Alert Items Data lossManual Organization Product Manual SAS Interface ManualThis page is intentionally left blank Contents Installation ContentsError Analysis Figures Tables This page is intentionally left blank Standard Features Hardware Structure System Configuration Standard FeaturesGeneral Description Standard Features General Description Hardware Structure Sata style cable SAS Plug Connector Receptacle connector System Configuration This page is intentionally left blank Model names and order numbers Hardware SpecificationsHardware Specifications Model name and order number MBB2147RC MBB2073RC SpecificationsFunction specifications 60/62 MeeprmlHardware Specifications Seek time ms Seek difference 4096 Cly/divEnvironmental specifications Environmental/Power requirementsMtbf = Error rateReliability Specifications Data Space Cylinder configurationData Space Logical Data Block Addressing Defect Management Data Format Data Space Alternate spare area Spare area in cellTrack format Track skew/head skew Sector formatData Space Format capacity Logical Data Block Addressing Defect Management Defect list Alternate block allocationAlternate block allocation by Format Unit command Defect ManagementAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Installation Requirements Mounting Requirements DimensionsInstallation Requirements Mounting orientationsMounting Requirements Mounting frame structure exampleVent hole location MPU Surface temperature check point and maximum temperatureHDC +5VDC MBB2147RC MBB2073RC Power Supply Requirements Current waveform Max seekInterface connector CN1 power lines included Interface connector Connection RequirementsInterface connector SAS plug signal allocationCN1 Recommended connectors Ready LED output signalConnector requirements This page is intentionally left blank Installation Installation Mounting HDDs Mounting procedures SettingSetting Port Address Installation Formatting Installation Setting parameters Retry Count AT Verification AwreArre Arre Awre PERMaximum PRE-FETCH Disable PRE-FETCH Transfer Length Xffff Minimum PRE-FETCHDisc Maximum PRE-FETCH Ceiling Xffff Number of Cache SegmentsReady LED Meaning Diagnostics Self-diagnostics Self-diagnostic functionsDiagnostics and Maintenance Diagnostics Test programs Maintenance PrecautionsMaintenance requirements Maintenance levels Tools and test equipmentTest flowchart TestsOperation Check Initial seek operation check Diagnostic testOperation Check Operation testTroubleshooting Outline of troubleshooting procedures Troubleshooting with HDD replacement in the fieldTroubleshooting System-level field troubleshootingTroubleshooting at the repair site HDD troubleshootingFinding possibly faulty parts TroubleshootingTroubleshooting with parts replacement in the factory Bag packaging Packaging Box packagingFraction packaging Sense data format Sense Data Collection Sense Data AnalysisSense Data Collection Sense data LSB Error AnalysisILI SksvSense Data Analysis Definition of sense dataSense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read error Sense data 3-0C-03, 4-32-01, 4-40-xx, 4-C4-xx,Glossary This page is intentionally left blank Acronyms and Abbreviations Acronyms and Abbreviations Bcrc ECCMtbf Mttr Mode SELECT/MODE SelectIndex PADIndex This page is intentionally left blank Comment Form This page is intentionally left blank