Fujitsu MBB2073RC, MBB2147RC manual Setting parameters

Page 63

5.4Checking Operation after Installation and Preparing the HDDs for Use

5.4.3Setting parameters

The user can specify the optimal operation mode for the user system environments by setting the following parameters with the MODE SELECT or MODE SELECT EXTENDED command:

Error recovery parameter

Caching parameter

Control mode parameter

With the MODE SELECT or MODE SELECT EXTENDED command, specify 1 for the "SP" bit on CDB to save the specified parameter value on the disk. This enables the HDDs to operate by using the parameter value set by the user when power is turned on again.

When the parameters are not set or saved with the MODE SELECT or MODE SELECT EXTENDED command, the HDDs set the default values for parameters and operates when power is turned on or after reset. Although the HDD operations are assured with the default values, the operations are not always optimal for the system. To obtain the best performance, set the parameters in consideration of the system requirements specific to the user.

This section outlines the parameter setting procedures. Refer to Subsection 4.1.4 “MODE

SELECT (15)”, 4.1.5 “MODE SELECT EXTENDED (55)” of the SAS INTERFACE MANUAL for further details of the MODE SELECT and MODE SELECT EXTENDED commands and specifying the parameters.

1.At factory shipment of the HDDs, the saving operation for the MODE SELECT parameter is not executed. So, if the user does not set parameters, the HDDs operate according to the default value of each parameter.

2.The MODE SELECT parameter is not saved for each Loop ID of but as the common parameter for all initiator. In the multi-initiator system, parameter setting cannot be changed for each initiator.

3.Once parameters are saved, the saved value is effective as long as next saving operation is executed from the initiator. For example, even if the initialization of the disk is performed by the FORMAT UNIT command, the saved value of parameters described in this section is not affected.

4.When the HDDs, to which the saving operation has been executed on a system, are connected to another system, the user must pay attention to that the HDDs operate according to the saved parameter value if the saving operation is not executed at installation.

5.The saved value of the MODE SELECT parameter is assumed as the initial value of each parameter after the power-on, the RESET condition. The initiator can change the parameter value temporary (actively) at any timing by issuing the MODE SELECT or MODE SELECT EXTENDED command with specifying "0" to the SP bit in the CDB.

C141-E257

59

Image 63
Contents MBB2147RC MBB2073RC Hard Disk Drives Product Manual For Safe Operation Revision Record Related Standards Overview of Manual PrefaceConventions for Alert Messages PrefaceImportant Alert Messages Important Alert ItemsData loss Important Alert ItemsSAS Interface Manual Manual Organization Product ManualThis page is intentionally left blank Contents Contents InstallationError Analysis Figures Tables This page is intentionally left blank Standard Features Standard Features Hardware Structure System ConfigurationGeneral Description Standard Features General Description Hardware Structure Sata style cable SAS Plug Connector Receptacle connector System Configuration This page is intentionally left blank Hardware Specifications Hardware Specifications Model name and order numberModel names and order numbers 60/62 Meeprml SpecificationsFunction specifications MBB2147RC MBB2073RCSeek time ms Seek difference 4096 Cly/div Hardware SpecificationsEnvironmental/Power requirements Environmental specificationsError rate ReliabilityMtbf = Specifications Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Data Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements Dimensions Installation RequirementsMounting orientations Installation RequirementsMounting frame structure example Mounting RequirementsVent hole location Surface temperature check point and maximum temperature HDCMPU +5VDC MBB2147RC MBB2073RC Current waveform Max seek Power Supply RequirementsInterface connector CN1 power lines included Connection Requirements Interface connectorInterface connector SAS plug signal allocationCN1 Ready LED output signal Connector requirementsRecommended connectors This page is intentionally left blank Installation Installation Setting Setting Port AddressMounting HDDs Mounting procedures Installation Formatting Installation Setting parameters Arre Awre PER AwreArre Retry Count AT VerificationMaximum PRE-FETCH Ceiling Xffff Number of Cache Segments Disable PRE-FETCH Transfer Length Xffff Minimum PRE-FETCHDisc Maximum PRE-FETCHReady LED Meaning Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Precautions MaintenanceMaintenance requirements Tools and test equipment Maintenance levelsTests Test flowchartOperation test Diagnostic testOperation Check Operation Check Initial seek operation checkTroubleshooting with HDD replacement in the field Troubleshooting Outline of troubleshooting proceduresSystem-level field troubleshooting TroubleshootingHDD troubleshooting Troubleshooting at the repair siteTroubleshooting Troubleshooting with parts replacement in the factoryFinding possibly faulty parts Bag packaging Box packaging PackagingFraction packaging Sense Data Collection Sense Data Analysis Sense Data Collection Sense dataSense data format Sksv Error AnalysisILI LSBDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-32-01, 4-40-xx, 4-C4-xx, Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorGlossary This page is intentionally left blank Acronyms and Abbreviations Acronyms and Abbreviations ECC BcrcPAD Mode SELECT/MODE SelectIndex Mtbf MttrIndex This page is intentionally left blank Comment Form This page is intentionally left blank