6.1 Diagnostics

(2)Online self-diagnostics (SEND DIAGNOSTIC command)

The initiator can make the HDDs execute self-diagnostics by issuing the SEND DIAGNOSTIC command.

The initiator specifies the execution of self-diagnostics by setting 1 for the SelfTest bit on the CDB in the SEND DIAGNOSTIC command and specifies the test contents with the UnitOfl bit.

When the UnitOfl bit on the CDB is set to 0, the HDDs execute the hardware function test only once. When UnitOfl bit is set to 1, the HDDs execute the hardware function test, seek (positioning) test, and data write/read test for the Internal test space only once.

a.Error recovery during self-diagnostics

During the self-diagnostics specified by the SEND DIAGNOSTIC command, when the recoverable error is detected during the seek or the write/read test, the HDDs perform the error recovery according to the MODE SELECT parameter value (read/write error recovery parameter, additional error recovery parameter) which the initiator specifies at the time of issuing the SEND DIAGNOSTIC command.

PER

Operation of self-diagnostics

0The self-diagnostics continues when the error is recovered. The self- diagnostics terminates normally so far as the unrecoverable error is not detected.

1The self-diagnostics continues when the error is recovered. If the unrecoverable error is not detected, the consecutive tests are executed till last test but the self-diagnostics terminates with error. The error information indicates that of the last recovered error.

b.Reporting result of self-diagnostics and error indication

When all specified self-diagnostics terminate normally, the HDDs post the GOOD status for the SEND DIAGNOSTIC command.

When an error is detected in the self-diagnostics, the HDDs terminate the SEND DIAGNOSTIC command with the CHECK CONDITION status.

When the CHECK CONDITION status is posted, sense data contains detailed information on the error detected by the initial self-diagnostics.

The HDD status after the CHECK CONDITION status is posted differs according to the type of the detected error.

a)When an error is detected in the seek or write/read test, the subsequent command can be accepted correctly. When the command other than the REQUEST SENSE is issued from the same initiator, the error information (sense data) is cleared.

C141-E257

65

Image 69
Contents MBB2147RC MBB2073RC Hard Disk Drives Product Manual For Safe Operation Revision Record Related Standards Overview of Manual PrefaceConventions for Alert Messages PrefaceImportant Alert Messages Important Alert ItemsData loss Important Alert ItemsSAS Interface Manual Manual Organization Product ManualThis page is intentionally left blank Contents Contents InstallationError Analysis Figures Tables This page is intentionally left blank Standard Features Standard Features Hardware Structure System ConfigurationGeneral Description Standard Features General Description Hardware Structure Sata style cable SAS Plug Connector Receptacle connector System Configuration This page is intentionally left blank Hardware Specifications Hardware Specifications Model name and order numberModel names and order numbers Function specifications SpecificationsMBB2147RC MBB2073RC 60/62 MeeprmlSeek time ms Seek difference 4096 Cly/div Hardware SpecificationsEnvironmental/Power requirements Environmental specificationsError rate ReliabilityMtbf = Specifications Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Data Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements Dimensions Installation RequirementsMounting orientations Installation RequirementsMounting frame structure example Mounting RequirementsVent hole location Surface temperature check point and maximum temperature HDCMPU +5VDC MBB2147RC MBB2073RC Current waveform Max seek Power Supply RequirementsInterface connector CN1 power lines included Connection Requirements Interface connectorInterface connector SAS plug signal allocationCN1 Ready LED output signal Connector requirementsRecommended connectors This page is intentionally left blank Installation Installation Setting Setting Port AddressMounting HDDs Mounting procedures Installation Formatting Installation Setting parameters Arre AwreRetry Count AT Verification Arre Awre PERDisc Disable PRE-FETCH Transfer Length Xffff Minimum PRE-FETCHMaximum PRE-FETCH Maximum PRE-FETCH Ceiling Xffff Number of Cache SegmentsReady LED Meaning Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Precautions MaintenanceMaintenance requirements Tools and test equipment Maintenance levelsTests Test flowchartOperation Check Diagnostic testOperation Check Initial seek operation check Operation testTroubleshooting with HDD replacement in the field Troubleshooting Outline of troubleshooting proceduresSystem-level field troubleshooting TroubleshootingHDD troubleshooting Troubleshooting at the repair siteTroubleshooting Troubleshooting with parts replacement in the factoryFinding possibly faulty parts Bag packaging Box packaging PackagingFraction packaging Sense Data Collection Sense Data Analysis Sense Data Collection Sense dataSense data format ILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-32-01, 4-40-xx, 4-C4-xx, Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorGlossary This page is intentionally left blank Acronyms and Abbreviations Acronyms and Abbreviations ECC BcrcIndex Mode SELECT/MODE SelectMtbf Mttr PADIndex This page is intentionally left blank Comment Form This page is intentionally left blank