Fujitsu MBB2073RC, MBB2147RC manual Index

Page 93

Index

storage

54

sync mark

33

system configuration

18

system space

29

T

 

test

70

test program

66

tool and test equipment

69

track format

31

track skew and head skew

31

troubleshooting at repair site

74

troubleshooting procedure

72

troubleshooting with HDD replacement

 

in field

72

troubleshooting with part replacement in

 

factory

75

U

 

unpackaging

54

unrecoverable error rate

25

user space

29

V

 

vent hole

44

verify error recovery parameter

60

verifying HDD operation

56

verifying interface connection

56

W

 

write/read test

64

C141-E257

89

Image 93
Contents MBB2147RC MBB2073RC Hard Disk Drives Product Manual For Safe Operation Revision Record Related Standards Overview of Manual PrefaceConventions for Alert Messages PrefaceImportant Alert Messages Important Alert ItemsData loss Important Alert ItemsSAS Interface Manual Manual Organization Product ManualThis page is intentionally left blank Contents Contents InstallationError Analysis Figures Tables This page is intentionally left blank Standard Features Standard Features Hardware Structure System ConfigurationGeneral Description Standard Features General Description Hardware Structure Sata style cable SAS Plug Connector Receptacle connector System Configuration This page is intentionally left blank Hardware Specifications Hardware Specifications Model name and order numberModel names and order numbers Function specifications SpecificationsMBB2147RC MBB2073RC 60/62 MeeprmlSeek time ms Seek difference 4096 Cly/div Hardware SpecificationsEnvironmental/Power requirements Environmental specificationsError rate ReliabilityMtbf = Specifications Cylinder configuration Data Space Logical Data Block Addressing Defect ManagementData Space Data Format Data Space Spare area in cell Alternate spare areaTrack format Sector format Track skew/head skewData Space Format capacity Logical Data Block Addressing Alternate block allocation Defect Management Defect listDefect Management Alternate block allocation by Format Unit commandAlternate block allocation by Reassign Blocks command Write Write Extend Write Write Extended Format Unit Mounting Requirements Dimensions Installation RequirementsMounting orientations Installation RequirementsMounting frame structure example Mounting RequirementsVent hole location Surface temperature check point and maximum temperature HDCMPU +5VDC MBB2147RC MBB2073RC Current waveform Max seek Power Supply RequirementsInterface connector CN1 power lines included Connection Requirements Interface connectorInterface connector SAS plug signal allocationCN1 Ready LED output signal Connector requirementsRecommended connectors This page is intentionally left blank Installation Installation Setting Setting Port AddressMounting HDDs Mounting procedures Installation Formatting Installation Setting parameters Arre AwreRetry Count AT Verification Arre Awre PERDisc Disable PRE-FETCH Transfer Length Xffff Minimum PRE-FETCHMaximum PRE-FETCH Maximum PRE-FETCH Ceiling Xffff Number of Cache SegmentsReady LED Meaning Self-diagnostic functions Diagnostics Self-diagnosticsDiagnostics and Maintenance Diagnostics Test programs Precautions MaintenanceMaintenance requirements Tools and test equipment Maintenance levelsTests Test flowchartOperation Check Diagnostic testOperation Check Initial seek operation check Operation testTroubleshooting with HDD replacement in the field Troubleshooting Outline of troubleshooting proceduresSystem-level field troubleshooting TroubleshootingHDD troubleshooting Troubleshooting at the repair siteTroubleshooting Troubleshooting with parts replacement in the factoryFinding possibly faulty parts Bag packaging Box packaging PackagingFraction packaging Sense Data Collection Sense Data Analysis Sense Data Collection Sense dataSense data format ILI Error AnalysisLSB SksvDefinition of sense data Sense Data AnalysisSense data 3-0C-03, 4-32-01, 4-40-xx, 4-C4-xx, Sense data 1-1x-xx, 3-1x-xx and E-1D-00 Disk read errorGlossary This page is intentionally left blank Acronyms and Abbreviations Acronyms and Abbreviations ECC BcrcIndex Mode SELECT/MODE SelectMtbf Mttr PADIndex This page is intentionally left blank Comment Form This page is intentionally left blank