This section describes the button specifications.
Manual button
This button is used to select manual feed mode. Pressing this button switches the setting between Manual mode and ADF mode.
When this button is pressed, the scanner enters manual feed mode and the hopper goes up. If the button is pressed again, the scanner exits manual feed mode and the hopper goes down.
Start / Stop button
These buttons are usedd in
Stop button is also used in
Mode 1 button
This button is used to transit to SETUP mode when the power is on. When Mode 1 button is pressed and power is turned on, the scanner enters SETUP mode.
Mode 2 button
This button is used to transit to maintenance mode when the power is on. When Mode 2 button is pressed and power switch is turned on, the scanner enters maintenance mode. Maintenance mode is used for maintenance/diagnostic purpose. See M3099EX/GX/EH/GH IMAGE SCANNER CE MANUAL.