Cabletron Systems EMM-E6 manual Status, Media Type

Page 34

Using the EMM-E6 Hub View

Not Supported — The selected port does not support the Link feature, so the EMM-E6 cannot determine link status; this value will show only for thin coax (BNC), AUI, or transceiver ports.

NOTE

The fact that thin coax (BNC), AUI, and transceiver ports do not support the link feature can cause some misleading port status indicators: for example, a BNC port may show as segmented when, in fact, the cable has been disconnected; or an AUI or transceiver port may appear to have an active link when no cable has been attached. You should keep these anomalies in mind when troubleshooting a hub so equipped.

Unknown — The EMM-E6 can’t determine a link status.

Status

The port’s Status can be one of three states:

Segmented—A port becomes segmented (that is, disabled by the repeater module) when the port experiences 32 consecutive collisions, or when the port’s collision detector is on for longer than approximately 2 to 3 milliseconds.

NOTE

Because they do not support the link feature, thin coax (BNC) ports will display as segmented when there is no cable or terminator attached or the cable or terminator has been disconnected (i.e., a “no link” condition).

Active —The port is operating normally.

Unknown — The EMM-E6 cannot determine port status.

Active Users

Each active source address communicating through the port is counted as an active user. If Active Users is greater than two (or one for firmware versions previous to 2.00.16), it indicates that the port is supporting a trunk connection.

Media Type

Indicates the type of cable segment connected to the port. MIMs generally support a single media type. The supported media types are:

BNC (thin coax)

AUI

Transceiver Port AUI

Twisted Pair: RJ45 conn(ector)

Twisted Pair: DB9 conn

Twisted Pair: RJ71 conn

Multi-Mode Fiber: SMA conn

Multi-Mode Fiber: ST conn

BNC EPIM

2-18

Monitoring Hub Performance

Image 34
Contents EMM-E6 Page Virus Disclaimer Restricted Rights Notice Contents Chapter Source Addressing Chapter SecurityChapter Front Panel Redundancy Appendix a EMM-E6 MIB StructureContents Using the EMM-E6 User’s Guide IntroductionUsing the EMM-E6 User’s Guide What’s not in the EMM-E6 User’s Guide UPSConventions Screen Displays Window ConventionsUsing the Mouse ButtonGetting Help EMM-E6 Firmware Year 2000 ComplianceUsing the EMM-E6 Hub View Using the Hub ViewNavigating Through the Hub View Hub View Front PanelDevice Name UptimeDate and Time Device LocationUsing the EMM-E6 Hub View EMM-E6 Ports Display Using the Mouse in a Hub View Module Brim PortsHub View Port Color Codes Port Display FormMonitoring Hub Performance Port Display Form Traffic ErrorsLoad CollisionsFrame Sizes ProtocolsPort Type Using the EMM-E6 Hub View Name and Location Checking Device Status and Updating Front Panel InfoContact Checking Network Status Chassis TypeName Active UsersChecking Module Status Module TypeChecking Port Status Link StatusStatus Media TypeViewing the IP Address Table Topology TypeLaunching the Global Find MAC Address Tool Checking StatisticsUsing the EMM-E6 Hub View Avg Packet Size Received BytesTotal Packets Broadcast PacketsCRC Errors Total ErrorsAlignment Errors OOW CollisionsRunt Frames Giant FramesViewing the Port Source Address List Protocols/Frames StatisticsUsing the EMM-E6 Hub View Setting the Polling Intervals Managing the HubContact Status Device General StatusPort Operational State Configuring FNB ConnectionsDevice Configuration StatisticsConfiguring RIC MIM Connections To configure FNB connectivity for an individual port Setting a Port’s Trunk Type 15. Tpxmim Channel Selection WindowTo change a port’s topology status Enabling/Disabling MIM Ports Alarm Configuration From the icon Using Alarm ConfigurationFrom the command line stand-alone mode From the Hub ViewConfiguring Alarms CRCSetting Repeater Alarms BroadcastSetting and Changing Alarms Set Repeater Alarms WindowSetting Module and Port Alarms Setting Module AlarmsSet Module Alarms Window Set the Status to EnabledSetting Port Alarms Set Port Alarms WindowSet the Status to Enabled Alarm Configuration Setting Module and Port Alarms What is a Segmentation Trap? Link/Seg TrapsWhat is a Link Trap? Enabling and Disabling Link/Seg TrapsSpmarun r4hwtr IP address community name Configuring Link/Seg Traps for the Repeater Viewing and Configuring Link/Seg Traps for Hub ModulesModule Traps Window Viewing and Configuring Link/Seg Traps for Ports Port Traps WindowLink/Seg Traps Link/Seg Traps Enabling and Disabling Link/Seg Traps Setting Network Circuit Redundancy Repeater RedundancyConfiguring a Redundant Circuit Spmarun r4red IP address community nameChannel X Redundancy Window Add Circuit Address Window Repeater Redundancy Monitoring Redundancy To set the Poll IntervalSource Addressing Displaying the Source Address ListDisplaying the Source Address List Source Addressing Setting the Hash Type Setting the Aging TimeLocking Source Addresses Source Address Locking on Older Devices Configuring Source Address Traps Repeater-level Traps Module- and Port-level Traps Source Addressing Finding a Source Address Port Source Address Traps WindowClick on to exit the window Security What is LANVIEWSECURE? Spmarun r4sec IP address SU community nameSecure address assignment New definitions for station and trunk portsTrunk port security Configurable violation response Newest Lanviewsecure FeaturesContinuous learning mode Full or partial security against eavesdroppingSecurity on Non-LANVIEWSECUREMIMs Learned addresses resetForced non-secure status Configuring Security Security To assign secure addresses to a port Addresses Window Boards with Multiple Caches Add MAC Address WindowResetting Learned Addresses Tips for Successfully Implementing Eavesdropper ProtectionEnabling Security and Traps Security Repeater-level Security and Traps Channel X Security WindowModule-level Security and Traps Channel X Module Security Window Port-level Security and Traps Channel X Port Security WindowSecurity Setting Front Panel Redundancy Front Panel RedundancySetting Front Panel Redundancy Add Circuit Address Window Front Panel Redundancy Setting Front Panel Redundancy Ietf MIB Support EMM-E6 MIB StructureMIB Components Chassis MGRRepeater One, Repeater Two, and Repeater Three Host ServicesIP Services Ctron Use OnlyMIB Navigator Rmon DefaultDistributed LAN Monitor Rmon HostBrief Word About MIB Components and Community Names EMM-E6 MIB Structure Index Index-2 Index-3 Index Index-4