Cabletron Systems EMM-E6 manual Set Module Alarms Window, Set the Status to Enabled

Page 57

Alarm Configuration

Figure 3-3. Set Module Alarms Window

3.Select one or more modules in the scroll list. To apply one set of conditions to all modules, you can either select each module in the list or use the Set Alarm For box at the bottom of the window to choose either Selected Modules, which applies the conditions to the modules you selected in the module list, or All Modules, which applies the conditions to all modules in the hub network.

4.Click mouse button 1 on one of the four Alarm Types: Collisions, Errors, Traffic, or Broadcast. (Alarm Types not available for this device are grayed.) If you select Errors, the Mask check boxes become active and you can select all or just some of the five error types. The Error MaskCARGO, displayed in the module list, is an acronym for the error types: C = CRC, A = Alignment, R = Runts, G = Giants, O = OOW Collisions.

5.Set the Status to Enabled.

6.Highlight and edit the Alarm Threshold, which is the percentage of errors/total packets, or the number of traffic packets, broadcast packets, or collisions/good packet within the Timebase that will activate the alarm.

Setting Module and Port Alarms

3-7

Image 57
Contents EMM-E6 Page Virus Disclaimer Restricted Rights Notice Contents Chapter Security Chapter Source AddressingAppendix a EMM-E6 MIB Structure Chapter Front Panel RedundancyContents Introduction Using the EMM-E6 User’s GuideUsing the EMM-E6 User’s Guide UPS What’s not in the EMM-E6 User’s GuideConventions Window Conventions Screen DisplaysButton Using the MouseGetting Help Year 2000 Compliance EMM-E6 FirmwareUsing the Hub View Using the EMM-E6 Hub ViewHub View Front Panel Navigating Through the Hub ViewDate and Time UptimeDevice Name Device LocationUsing the EMM-E6 Hub View EMM-E6 Ports Display Brim Ports Using the Mouse in a Hub View ModulePort Display Form Hub View Port Color CodesMonitoring Hub Performance Port Display Form Load ErrorsTraffic CollisionsProtocols Frame SizesPort Type Using the EMM-E6 Hub View Checking Device Status and Updating Front Panel Info Name and LocationContact Chassis Type Checking Network StatusActive Users NameModule Type Checking Module StatusLink Status Checking Port StatusMedia Type StatusTopology Type Viewing the IP Address TableChecking Statistics Launching the Global Find MAC Address ToolUsing the EMM-E6 Hub View Total Packets Received BytesAvg Packet Size Broadcast PacketsAlignment Errors Total ErrorsCRC Errors OOW CollisionsGiant Frames Runt FramesProtocols/Frames Statistics Viewing the Port Source Address ListUsing the EMM-E6 Hub View Managing the Hub Setting the Polling IntervalsDevice General Status Contact StatusDevice Configuration Configuring FNB ConnectionsPort Operational State StatisticsConfiguring RIC MIM Connections To configure FNB connectivity for an individual port 15. Tpxmim Channel Selection Window Setting a Port’s Trunk TypeTo change a port’s topology status Enabling/Disabling MIM Ports Alarm Configuration From the command line stand-alone mode Using Alarm ConfigurationFrom the icon From the Hub ViewCRC Configuring AlarmsBroadcast Setting Repeater AlarmsSet Repeater Alarms Window Setting and Changing AlarmsSetting Module Alarms Setting Module and Port AlarmsSet the Status to Enabled Set Module Alarms WindowSet Port Alarms Window Setting Port AlarmsSet the Status to Enabled Alarm Configuration Setting Module and Port Alarms Link/Seg Traps What is a Segmentation Trap?Enabling and Disabling Link/Seg Traps What is a Link Trap?Spmarun r4hwtr IP address community name Viewing and Configuring Link/Seg Traps for Hub Modules Configuring Link/Seg Traps for the RepeaterModule Traps Window Port Traps Window Viewing and Configuring Link/Seg Traps for PortsLink/Seg Traps Link/Seg Traps Enabling and Disabling Link/Seg Traps Repeater Redundancy Setting Network Circuit RedundancySpmarun r4red IP address community name Configuring a Redundant CircuitChannel X Redundancy Window Add Circuit Address Window Repeater Redundancy To set the Poll Interval Monitoring RedundancyDisplaying the Source Address List Source AddressingDisplaying the Source Address List Source Addressing Setting the Aging Time Setting the Hash TypeLocking Source Addresses Source Address Locking on Older Devices Configuring Source Address Traps Repeater-level Traps Module- and Port-level Traps Source Addressing Port Source Address Traps Window Finding a Source AddressClick on to exit the window Security Spmarun r4sec IP address SU community name What is LANVIEWSECURE?New definitions for station and trunk ports Secure address assignmentTrunk port security Continuous learning mode Newest Lanviewsecure FeaturesConfigurable violation response Full or partial security against eavesdroppingLearned addresses reset Security on Non-LANVIEWSECUREMIMsForced non-secure status Configuring Security Security To assign secure addresses to a port Addresses Window Add MAC Address Window Boards with Multiple CachesTips for Successfully Implementing Eavesdropper Protection Resetting Learned AddressesEnabling Security and Traps Security Channel X Security Window Repeater-level Security and TrapsModule-level Security and Traps Channel X Module Security Window Channel X Port Security Window Port-level Security and TrapsSecurity Front Panel Redundancy Setting Front Panel RedundancySetting Front Panel Redundancy Add Circuit Address Window Front Panel Redundancy Setting Front Panel Redundancy EMM-E6 MIB Structure Ietf MIB SupportChassis MGR MIB ComponentsIP Services Host ServicesRepeater One, Repeater Two, and Repeater Three Ctron Use OnlyDistributed LAN Monitor Rmon DefaultMIB Navigator Rmon HostBrief Word About MIB Components and Community Names EMM-E6 MIB Structure Index Index-2 Index-3 Index Index-4