Cisco Systems IE301016S8PC manual Inch 6.8 mm

Page 19

Cisco IE 3010 Switch Getting Started Guide

Step 3 Use a Phillips screwdriver to loosen the captive screw on the power-input terminal, and open the cover.

Step 4 Use twisted-pair copper wire (14- to 18-AWG) long enough to connect from the power-input terminal to the power source.

Note Use 12-AWG (minimum) for the low-voltage DC power supply module, and use 16-AWG (minimum) for the high-voltage AC or DC power supply module.

Step 5 Strip each of the two wires to 0.25 inch (6.3

mm)± 0.02 inch (0.5 mm). Do not strip more than 0.27 inch (6.8 mm) of insulation from the wire. Stripping more than the recommended amount of wire can leave exposed wire from the connector after installation.

Step 6 Insert the wire into a spade terminal, and crimp the spade terminal to the wire.

Note You can use a ring, spade, or flanged spade terminal.

0.27 inch (6.8 mm)

208565

207225

 

 

Cisco IE 3010 Switch Getting Started Guide

 

 

 

 

 

 

78-19582-02

 

 

19

 

 

 

Image 19
Contents Cisco IE 3010 Switch Getting Started Guide About this Guide Box Contents Running Express Setup Troubleshooting 207181 Troubleshooting Cisco IE 3010 Switch Getting Started Guide 78-19582-02 Switch RJ-45 Console Port Managing the SwitchSwitch USB Console Port Equipment That You Need Installing the SwitchBefore You Begin 140F 60C Statement Installation Warning StatementsAttaching the Brackets Rack-Mounting the Switch 208334 Grounding the Switch Wiring the Power Source119626 AC 5 A, DC 15 A. Statement Connecting to the Power SourceInch 6.8 mm Cisco IEE 208338 10/100 or 10/100/1000 Ports Connecting the Switch PortsVerify Port Connectivity SFP-Module PortsExpress Setup TroubleshootingResetting the Switch to the Default Settings Obtaining Documentation and Submitting a Service RequestAccessing Help Online For More Information