DC power:

Insert the positive wire into the terminal screw labeled +, and the negative wire into the terminal screw labeled –.

Make sure that you cannot see any wire lead. Only wire with insulation should extend from the terminal screw.

Note If you have a low-voltage DC power supply module, connect the wires to the terminal screws labeled Lo. If you have a high-voltage DC power supply module connect the wires to the terminal screws labeled Hi.

Cisco IE 30110

208338

Step 9 Torque the captive screws (above the installed wire leads) to 8.5 in-lb (± 0.5 in-lb). Step 10 AC power:

Connect the other end of the line wire (the one connected to L) to the line terminal on the AC-power source, and connect the other end of the neutral wire (the one connected to N) to the neutral terminal on the AC power source.

DC power:

Connect the other end of the positive wire (the one connected to +) to the positive terminal on the DC power source, and connect the other end of the negative wire (the one connected to –) to the negative terminal on the DC power source.

Step 11 When you are testing the switch, one power connection is sufficient. If you are installing the switch and are using a second power source, repeat Step 3 through Step 10.

Step 12 Close the power-input terminal cover. Use a ratcheting torque screwdriver to torque the screw to 6–8 in-lb.

 

 

Cisco IE 3010 Switch Getting Started Guide

 

 

 

 

 

 

78-19582-02

 

 

21

 

 

 

Image 21
Contents Cisco IE 3010 Switch Getting Started Guide About this Guide Box Contents Running Express Setup Troubleshooting 207181 Troubleshooting Cisco IE 3010 Switch Getting Started Guide 78-19582-02 Managing the Switch Switch RJ-45 Console PortSwitch USB Console Port Equipment That You Need Installing the SwitchBefore You Begin 140F 60C Statement Installation Warning StatementsAttaching the Brackets Rack-Mounting the Switch 208334 Grounding the Switch Wiring the Power Source119626 AC 5 A, DC 15 A. Statement Connecting to the Power SourceInch 6.8 mm Cisco IEE 208338 10/100 or 10/100/1000 Ports Connecting the Switch PortsVerify Port Connectivity SFP-Module PortsExpress Setup TroubleshootingObtaining Documentation and Submitting a Service Request Resetting the Switch to the Default SettingsAccessing Help Online For More Information