Cisco Systems IE301016S8PC manual 208338

Page 21

Cisco IE 3010 Switch Getting Started Guide

DC power:

Insert the positive wire into the terminal screw labeled +, and the negative wire into the terminal screw labeled .

Make sure that you cannot see any wire lead. Only wire with insulation should extend from the terminal screw.

Note If you have a low-voltage DC power supply module, connect the wires to the terminal screws labeled Lo. If you have a high-voltage DC power supply module connect the wires to the terminal screws labeled Hi.

Cisco IE 30110

208338

Step 9 Torque the captive screws (above the installed wire leads) to 8.5 in-lb (± 0.5 in-lb). Step 10 AC power:

Connect the other end of the line wire (the one connected to L) to the line terminal on the AC-power source, and connect the other end of the neutral wire (the one connected to N) to the neutral terminal on the AC power source.

DC power:

Connect the other end of the positive wire (the one connected to +) to the positive terminal on the DC power source, and connect the other end of the negative wire (the one connected to ) to the negative terminal on the DC power source.

Step 11 When you are testing the switch, one power connection is sufficient. If you are installing the switch and are using a second power source, repeat Step 3 through Step 10.

Step 12 Close the power-input terminal cover. Use a ratcheting torque screwdriver to torque the screw to 6–8 in-lb.

 

 

Cisco IE 3010 Switch Getting Started Guide

 

 

 

 

 

 

78-19582-02

 

 

21

 

 

 

Image 21
Contents Cisco IE 3010 Switch Getting Started Guide About this Guide Box Contents Running Express Setup Troubleshooting 207181 Troubleshooting Cisco IE 3010 Switch Getting Started Guide 78-19582-02 Managing the Switch Switch RJ-45 Console PortSwitch USB Console Port Equipment That You Need Installing the SwitchBefore You Begin 140F 60C Statement Installation Warning StatementsAttaching the Brackets Rack-Mounting the Switch 208334 Grounding the Switch Wiring the Power Source119626 AC 5 A, DC 15 A. Statement Connecting to the Power SourceInch 6.8 mm Cisco IEE 208338 10/100 or 10/100/1000 Ports Connecting the Switch PortsVerify Port Connectivity SFP-Module PortsExpress Setup TroubleshootingObtaining Documentation and Submitting a Service Request Resetting the Switch to the Default SettingsAccessing Help Online For More Information