Step 1 Ensure that the spine module is connected to a COM port on a serial terminal device via the
a.If the managed spine is running, enter the following command at the console:
reboot
Then press Enter.
b.If the managed spine is not running, power on the switch.
Step 3 After selecting image1 or image2, press the Spacebar to interrupt the auto load sequence before the counter expires (within 5 seconds).
Step 4 At the [boot]: prompt enter the new spine IP address with the following syntax:
spineip <NEW IP ADDRESS>
Then press Enter.
Step 5 At the [boot]: prompt, enter reboot, and press Enter. Upon reboot the managed spine will display information similar to the following:
Unified Boot Manager For The T3 Platform.
Image Date: Jan 19 2006, 15:03:31
Checking L2 functionality...
BCM1125
L2 caches initialized and invalidated
CPU0 caches initialized
Initialized SMBUS Channels
SPD Checksum ok.
MEM_SEL = 0x00000007
CPU_REV = 0x00000001_112421FF
CPU speed = 400 MHz
IO Bridge 0,1 speed = 133, 200 MHz
Memory size = 128 MB
MC1 Configured for 128M SODIMM, CAS=2, 100 MHz
Configured Memory Size = 0x08000000
Channel Interleave Bit = 0
Number of Mem Channels = 1
Testing memory
Memory tests pass CPU0 flushing caches L2 flush complete Start type = 0xBFC006A0 Jumping to romStart Initializing HyperTransport bus HyperTransport initialization completed
rintf MBOX connect interrupt_source=28 vector=62 status=0 Printf MBOX intEnable status=0
Found Intel Strata Flash 128 MBit (0x8918).
Mounted raw file system on device /image1. (size=6291456 bytes)
Mounted raw file system on device /image2. (size=6291456 bytes)
Mounted raw file system on device /dump0. (size=1048576 bytes)
Mounted flash file system on device /rfa1. (size=2097152 bytes)
Unified Boot Manager
[1]image1
[2]image2
CPU: Broadcom BCM1125
VxWorks Version: 5.4
[boot]:
Unified Boot Manager For The T3 Platform.
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
32 |
|
|
|