Appendix A Wide Area Virtualization Engine Hardware Specifications
Appliance Specifications
Table | ||
|
| |
Specification | Description | |
|
|
|
Environment | • | Air temperature: |
|
| – Device on: 50 to 104°F (10 to 40°C); altitude: 0 to 2000 m |
|
| (6500 ft) |
|
| – Device off: |
|
| 9144 m (30000 ft) |
| • | Humidity |
|
| – Device on: 20 to 80% (noncondensing at ambient) |
|
| – Device off: 5 to 90% (noncondensing at ambient) |
|
| |
1Acoustical noise emissions • | Declared sound power, idle: 3.8 bel2 | |
| • Declared sound power, operating: 4.9 bel | |
|
| |
3Heat Output | • Minimum configuration: 1230 Btu4 (360 watts) |
•Maximum configuration: 3390 Btu (835 watts)
1.These levels were measured in controlled acoustical environments according to the procedures specified by the American National Standards Institute (ANSI) S12.10 and ISO 7779 and are reported in accordance with ISO 9296. Actual
2.In acoustics, the logarithm of the ratio of a quantity to a reference quantity of the same kind is called a level. The base of the logarithm (always ten, unless otherwise specified), the reference quantity, and the kind of level shall be specified. bel is a unit of level when the base of the logarithm is ten, and the quantities concerned are proportional to power.
3.Power consumption and heat output vary depending on the number and type of optional features installed and the
4.BTU = British Thermal Unit.
|
| Cisco Wide Area Virtualization Engine 274 and 474 Hardware Installation Guide |
|
|
|
|
| ||
|
|
|
| |
|
|
|