Chassis Ground Connection Installation

Before you connect power or turn on power to your router, you must provide an adequate chassis ground (earth) connection for the router chassis. A ground connector is provided on each Cisco ASR 1006 Router. See Figure 7.

Caution The dual-lug chassis stud must be installed, the SIP and SPA must be fully inserted and screwed in and earthed to prevent a potential hazard in a telecom line.

Have the recommended tools and supplies available before you begin this procedure: Phillips screwdriver, dual-lug chassis ground component, and grounding wire.

Step 1 Use the wire stripper to strip one end of the AWG #6 gauge wire approximately 0.75 inches (19.05 mm). Step 2 Insert the AWG #6 gauge wire into the wire receptacle on the grounding lug.

Step 3 Use the crimping tool to carefully crimp the wire receptacle around the wire; this step is required to ensure a proper mechanical connection.

Step 4 Attach the grounding lug with the wire so the grounding wire does not overlap the power supply.

Figure 7 Attaching a Grounding Lug to the Chassis Ground Connector

4

3

2 1

280034

1

Chassis earth ground studs and lead wire

3

Earth ground connector on the chassis

 

 

 

 

2

Grounding screws

4

Earth ground symbol

 

 

 

 

Step 5 Locate the chassis ground connector on the side of your chassis.

Step 6 Insert the two screws through the holes in the grounding lug.

Step 7 Use the Number 2 Phillips screwdriver to carefully tighten the screws until the grounding lug is held firmly to the chassis. Do not overtighten the screws.

12

Image 12
Contents Cisco ASR 1006 Router Documentation and Resources Document Revision HistoryPrepare for Installation Prepare for Equipment Shelf or Tabletop InstallationSite Preparation and Unpacking Tools and PartsPrepare for Rack-Mount Installation Rack-Mount the RouterAttach the Rack-Mount Brackets-Chassis Front-Mounted Attach the Rack-Mount Brackets-Chassis Rear Rack-Mounted Insert and tighten the black screws on one sideFour-Post Rack Installation Cisco ASR 1006 Router Rear Rack-MountingInstalling the Cisco ASR 1006 Router in a Four-Post Rack Two-Post Rack Installation Installing the Cisco ASR 1006 Router in a Two-Post Rack Attach the Cable-Management Bracket 280036 Chassis Ground Connection Installation Attaching a Grounding Lug to the Chassis Ground ConnectorConnect the Router to the Network Console and Auxiliary Port Cable ConnectionsManagement Ethernet Port Cable Connection Management Ethernet Port Connectors Connect the Shared Port Adapter CablesInstall the Cables in the Cable-Management Bracket Connecting AC-Input Power to the Cisco ASR 1006 RouterStart the System Connect DC Power to the Cisco ASR 1006 Router Plug the power cable into the inletUnit. Statement Installing the Cisco ASR 1006 Router DC Ground Lugs Wiring the DC-Input Power Source DC Power Supply Terminal Block 280024 280311 Verifying Power Supply Operation DC Power Supply Terminal Block and Plastic CoverStart the System Following output displaysActv Validatepackage SHA-1 hash Page Etherport Page Configure the Router Using the Console InterfaceConfigure Global Parameters Using the Setup Facility OK? No clns routing Tftptimeout Page Check the Running Configuration Settings Save the Running Configuration to NvramPerform Other Configuration Tasks After Installation Power Off the Cisco ASR 1006 RouterReplace a Power Supply in a Cisco ASR 1006 Router Remove and Then Replace an AC Power SupplyRemove the DC Power Supply Unit Might One All Install and Remove the Shared Port Adapter Replace the DC Power SupplyHandling a SPA Page USA