Cisco Systems quick start Replace a Power Supply in a Cisco ASR 1006 Router

Page 37

Replace a Power Supply in a Cisco ASR 1006 Router

This section provides instructions for removing and replacing the AC power supply and the DC power supply in a Cisco ASR 1006 Router. Before you begin, make certain the chassis is grounded.

Remove and Then Replace an AC Power Supply

To remove a live Cisco ASR 1006 Router AC power supply that is not operating normally (and then replace the AC power supply within five minutes), follow this procedure:

Step 1 Slip on the ESD-preventative wrist strap that was included in the accessory kit.

Step 2 Before you turn off a power supply, make certain the chassis is grounded.

Step 3 Turn the power supply Standby switch to the Standby position.of the power supply.

Step 4 Unplug the power cable from the AC inlet on the back of the power supply and the power source. Step 5 Unscrew the power supply captive screws.

Note Two power supplies must be installed in the chassis at all times to ensure sufficient cooling. The system fans are inside the power supply units and must spin for cooling. Because all the system fans can be powered by one power supply, the second power supply unit does not have to be powered on, but it must be installed.

Caution If you remove a power supply, the system can run for a maximum of five minutes before the system shuts down. The fans and power elements are independent within the power supply. Therefore, it is not required that the replacement power supply be energized within five minutes. The only requirement is that the power supply be installed in the chassis, which energizes the fans and maintains proper system cooling.

Step 6 Grasping the power supply handles, pull the power supply from the chassis. When you remove the AC power supply, you will see the following type of messages in the log report:

6ru_perf2#show log

Syslog logging: enabled (0 messages dropped, 6 messages rate-limited, 0 flushes, 0 overruns, xml disabled, filtering disabled)

No Active Message Discriminator.

No Inactive Message Discriminator.

Console logging: disabled

Monitor logging: level debugging, 0 messages logged, xml disabled, filtering disabled

Buffer logging: level debugging, 81 messages logged, xml disabled, filtering disabled

Exception Logging: size (4096 bytes)

Count and timestamp logging messages: disabled

Persistent logging: disabled

No active filter modules.

Trap logging: level informational, 78 message lines logged

Log Buffer (10000000 bytes):

*Jan 10 06:08:14.713: %CMRP-3-PEM_REMOVE_SHUT: R0/0: cmand: The system will shut down in 5 minutes

*Jan 10 06:08:14.718: %ASR1000_PEM-6-REMPEM_FM: PEM/FM slot P1 removed

*Jan 10 06:08:28.966: %ASR1000_PEM-6-INSPEM_FM: PEM/FM slot P1 inserted

37

Image 37
Contents Cisco ASR 1006 Router Document Revision History Documentation and ResourcesPrepare for Equipment Shelf or Tabletop Installation Prepare for InstallationSite Preparation and Unpacking Tools and PartsRack-Mount the Router Prepare for Rack-Mount InstallationAttach the Rack-Mount Brackets-Chassis Front-Mounted Insert and tighten the black screws on one side Attach the Rack-Mount Brackets-Chassis Rear Rack-MountedCisco ASR 1006 Router Rear Rack-Mounting Four-Post Rack InstallationInstalling the Cisco ASR 1006 Router in a Four-Post Rack Two-Post Rack Installation Installing the Cisco ASR 1006 Router in a Two-Post Rack Attach the Cable-Management Bracket 280036 Attaching a Grounding Lug to the Chassis Ground Connector Chassis Ground Connection InstallationConsole and Auxiliary Port Cable Connections Connect the Router to the NetworkManagement Ethernet Port Cable Connection Connect the Shared Port Adapter Cables Management Ethernet Port ConnectorsConnecting AC-Input Power to the Cisco ASR 1006 Router Install the Cables in the Cable-Management BracketStart the System Plug the power cable into the inlet Connect DC Power to the Cisco ASR 1006 RouterUnit. Statement Installing the Cisco ASR 1006 Router DC Ground Lugs Wiring the DC-Input Power Source DC Power Supply Terminal Block 280024 280311 DC Power Supply Terminal Block and Plastic Cover Verifying Power Supply OperationFollowing output displays Start the SystemActv Validatepackage SHA-1 hash Page Etherport Page Using the Console Interface Configure the RouterConfigure Global Parameters Using the Setup Facility OK? No clns routing Tftptimeout Page Save the Running Configuration to Nvram Check the Running Configuration SettingsPerform Other Configuration Tasks Power Off the Cisco ASR 1006 Router After InstallationRemove and Then Replace an AC Power Supply Replace a Power Supply in a Cisco ASR 1006 RouterRemove the DC Power Supply Unit Might One All Replace the DC Power Supply Install and Remove the Shared Port AdapterHandling a SPA Page USA