Contents
Hardware Reference Manual
Departmental Switch Model DS-16B
Copyright 2000 EMC Corporation. All rights reserved
Departmental Switch Model DS-16B Hardware Reference Manual
Trademark Information
FCC Warning USA only
Departmental Switch Model DS-16B Hardware Reference Manual
Contents
Appendix B Switch Support
Chapter Switch Management
Chapter Front Panel Diagnostics
Appendix a Specifications
Appendix C Error Messages
Departmental Switch Model DS-16B Hardware Reference Manual
Figures
Figures
Preface
For Information On See
Related Publications Conventions Used in This Manual
Ask for Customer Service
Command line arguments when used in text
Examples of specific command entries that you
Arguments used in examples of command line
Departmental Switch Model DS-16B Hardware Reference Manual
Introduction System Components
Introduction
Introduction
DS-16B Switch
Features
Following features
Ethernet port
Performance
Manageability
Unit may be managed in band or out of band via Telnet, via
GBICs
System Components
Fabric Operating
System
Installation
Unpacking the Switch
Requirements
Power Requirements
Site Considerations
Cooling
Fiber Channel
Installation Considerations
To install the adhesive rubber feet
Standalone
Test Post
Verify Power-On Self
Ethernet
Connection
Departmental Switch Model DS-16B Hardware Reference Manual
Switch Management
SES
Comparing Switch Management Access Methods
Control Buttons
Managing Through Front Panel Buttons
Front panel buttons activates the display
Select Menu Configuration Menu
Activating Menu
Display
Following menus are controlled using the front panel buttons
DS-16B Switch Menus
Menu Front Panel Telnet Command Default
Commands
Shows the front panel commands and their equivalent
Telnet command
Unset QuickLoop Port Configure QuickLoop Partner WWN
Cmem Data Retention Test
Ratov Edtov
Configuration Menu
Configuration menu See
Ethernet Subnetmask none
Configuration menu
Ethernet IP address 10
To enter an IP address
Fibre Channel Subnetmask
To update the Fibre Channel’s IP address
Fibre Channel IP Address
Fibre Channel IP address
BBcredit
Gateway address
To enter the gateway address
Domain
Edtov
Ratov Pressing Enter while Ratov is selected, displays
Ratov
Edtov Pressing Enter while Edtov is selected, displays
Operating modes are determined by the host adapter. The six
Operating Mode
Operating modes for the switch are
For the corresponding operating mode
VC Multicast
VC Link Ctl
VC Class 2
VC Class 3
Frame Collection Method? Bundle/Piling
Reset to Default Accept? Yes No
VC Priorities 0,1,2,2,2,2,3,3
Menu. Pressing Enter while the Operation Menu is selected
Default values
Allows you to select commands
Operation Menu
Operation Menu Port Disable
Switch Online
Operation Menu Switch Offline
Operation Menu Switch Online
Reboot Accept? Yes No
Operation Menu Port Enable
Port Enable Accept? Yes No
Operation Menu Reboot
Status Menu See
Switch Name sw15
Status Menu
Menu is informational only you cannot make changes to
Current Date Mon Oct 21 102335
Booted At Sat Sep 19 183420
Worldwide Name 1000606900e
Firmware Version
Up Time Day
Boot Prom Date Jun 12 084829 PST
Powered Time 137 days
Flash Date Jun 12 084829 PST
Port Throughput 75MB/s
Module TypeL
3Temperature Sensor Approximate Locations on Motherboard
Temperature 36 34 37 36
Feb 12 084829 Err SENSOR-FAILED-3
Error Log Selecting Error Log, then pressing Enter, displays
Licenses 01f
Test Menu
Licenses
Front Panel Diagnostics
Overview
Front Panel Diagnostics
Diagnostic
This section gives a diagnostic overview and discusses
Panel Displays
Diagnostic Front
Fault
Removing Power
Color and flash speed of each port’s LED, as described
Status and Activity Indicators
Indicators
Front Panel LED Port
Diagnostics Post
Power-On
Diagnostic Tests
Offline Tests Offline & Online Tests
Switch Offline Accept? Yes No
Switch Online Accept? Yes No
System Memory Test at 0x1021d460 len
0x10199a10 len 13091456 ramTest passed
Related error messages DIAG-MEMORY, DIAG-MEMSZ
Related error messages DIAG-REGERR, DIAG-REGERRUNRST
If the memory tests OK, the front panel displays
Central MemTest passed
Related error messages DIAG-CMBISTRO, DIAG-CMBISRF
Port Loopback Test Aborted
Related error messages DIAG-INIT, DIAG-PORTDIED
SpinSilk Press any button to terminate
Push Button Test To exit
Specifications
Specifications Description
General Specifications
Table A-1 shows the switch specifications
Table A-2 shows Fabric management specifications
Fabric Management Specifications
Safety
Safety Specifications
Table A-3 Shows Safety specifications
Optical Port
Specifications
Switch’s primary operating environments are server rooms
Specification Value
Table Top Dimensions
Power Supply
Dimensions
Rack Mount Dimensions
Switch Support
Support Tool
Switch Support
Error Messages
Feb 12
Error Message Formats
Front Panel
Message Formats
To display error message from the front panel
Failed test Replace
Diagnostic Error Message Formats
Numbers
Error Message
Error Number Test Name Error Name
DIAG-LCMEMTX
DIAG-TIMEOUT
DIAG-CMBISRTO
DIAG-CMBISRF
DIAG-ERRSTAT 2LONG
DIAG-ERRSTAT Encin
DIAG-ERRSTAT CRC
DIAG-ERRSTAT Trunc
DIAG-ERRSTAT2LONG
DIAG-ERRSTATENCIN
DIAG-ERRSTATCRL
DIAG-ERRSTATTRUNC
DIAG-PORTSTOPPED
Message Description Probable Cause Action
Error Message Tables
CMI message received failed bad
DIAG-ERRSTAT
Asic failure Replace Err#1F26
Message Description Probable Cause
FCIU, IUBAD, L, S
FLASH, Badmirror
RPC, Svcexit
RPC, Svcreg
MQ, QWRITE, L, M
FCIU, IUCOUNT, L, S
FCPH, EXCHBAD, L, S
FCPH, EXCHFREE, L, S
TIMERS, MSG,LOGWARNING
SYS BADPTR, Logerror
SYS FLASHRD, Logerror
SYS FLASHWR, Logerror
UCAST, RRTIM, Logcritical
Logerror
MCAST, Noparentlsr
Sales and Service Locations
Locations
International Sales
Departmental Switch Model DS-16B Hardware Reference Manual
Departmental Switch Model DS-16B Hardware Reference Manual
Index
Index
Departmental Switch Model DS-16B Hardware Reference Manual
Departmental Switch Model DS-16B Hardware Reference Manual