EMC DS-16B manual Fciu, Iucount, L, S, Fcph, Exchbad, L, S, Fcph, Exchfree, L, S, Mq, Qwrite, L, M

Page 88

Error Messages

 

Table C-4

System Error Messages (continued)

 

 

 

 

 

 

 

Message

 

 

Description

Probable Cause

Action

 

 

 

 

 

 

 

 

 

 

FCIU, IUCOUNT, L, S

 

Total number of IUs Count < 0

OS error

Contact customer support

 

 

 

 

 

FCPH, EXCHBAD, L, S

 

Bad exchange

OS error

Contact customer support

 

 

 

 

 

FCPH, EXCHFREE, L, S

 

Unable to free an exchange

OS error

Contact customer support

 

 

 

 

 

MQ, QWRITE, L, M

 

Message queue overflow

Task blocked

Contact customer support

 

 

 

 

 

 

MQ, QREAD, L, M

 

 

Message queue unread

OS error

Contact customer support

 

 

 

 

 

MQ, MSGTYPE, E, M

 

Unknown message type

OS error

Contact customer support

 

 

 

 

 

SEMA, SEMGIVE, L, M

 

Unable to give a semaphore

OS error

Contact customer support

 

 

 

 

 

SEMA, SEMTAKE, L, M

 

Unable to take a semaphore

OS error

Contact customer support

 

 

 

 

 

SEMA, SEMFLUSH, L, M

 

Unable to flush a semaphore

OS error

Contact customer support

 

 

 

 

 

PANIC, TASKSPAWN, LOG_PANIC

 

task creation failed

OS error

Contact customer support

 

 

 

 

 

PANIC, SEMCREATE, LOG_PANIC

 

Semaphore creation failed

OS error

Contact customer support

 

 

 

 

 

PANIC, SEMDELETE, LOG_PANIC

 

Semaphore deletion failed

OS error

Contact customer support

 

 

 

 

 

 

PANIC, QCREATE,

LOG_PANIC

 

Message queuer failed

OS error

Contact customer support

 

 

 

 

 

 

PANIC, QDELETE,

LOG_PANIC

 

Message queuer deletion failed

OS error

Contact customer support

 

 

 

 

 

 

PANIC, MALLOC,

LOG_PANIC

 

Memory allocation failed

OS error

Contact customer support

 

 

 

 

 

PANIC, FREE, LOG_PANIC

 

Memory free failed

OS error

Contact customer support

 

 

 

 

PANIC, INCONSISTENT, LOG_PANIC

Data out of sync

OS error

Contact customer support

 

 

 

 

 

PANIC, INTCONTEXT, LOG_PANIC

 

Data out of sync

OS error

Contact customer support

 

 

 

 

 

PANIC, ZOMTIMSET, LOG_PANIC

 

Attempt to set a zombie timer

OS error

Contact customer support

 

 

 

 

 

PANIC, ZOMTIMKILL, LOG_PANIC

 

Zombie timer destroyed

OS error

Contact customer support

 

 

 

 

PANIC, FREETIMRLSD, LOG_PANIC

Free timer released

OS error

Contact customer support

 

 

 

 

 

PANIC, TIMEUSECNT, LOG_PANIC

 

Timer use count exceeded

OS error

Contact customer support

 

 

 

 

 

PANIC, LSDB_CKSUM, LOG_PANIC

 

Link State Database checksum

OS error

Contact customer support

 

 

 

failed

 

 

 

 

 

 

 

SYS, NOMEM, LOG_CRITICAL

 

No memory

OS error

Contact customer support

 

 

 

 

 

SYS, SYSCALL, LOG_ERROR

 

System call failed

OS error

Contact customer support

 

 

 

 

 

 

Departmental Switch Model DS-16B Hardware Reference Manual

Image 88
Contents Departmental Switch Model DS-16B Hardware Reference ManualCopyright 2000 EMC Corporation. All rights reserved Departmental Switch Model DS-16B Hardware Reference Manual Trademark Information FCC Warning USA only Departmental Switch Model DS-16B Hardware Reference Manual Contents Chapter Switch Management Chapter Front Panel DiagnosticsAppendix a Specifications Appendix B Switch SupportAppendix C Error Messages Departmental Switch Model DS-16B Hardware Reference Manual Figures Figures Preface Related Publications Conventions Used in This Manual For Information On SeeCommand line arguments when used in text Examples of specific command entries that youArguments used in examples of command line Ask for Customer ServiceDepartmental Switch Model DS-16B Hardware Reference Manual Introduction Introduction System ComponentsDS-16B Switch FeaturesFollowing features IntroductionPerformance ManageabilityUnit may be managed in band or out of band via Telnet, via Ethernet portSystem Components Fabric OperatingSystem GBICsInstallation Unpacking the Switch Power Requirements Site ConsiderationsCooling RequirementsInstallation Considerations To install the adhesive rubber feetStandalone Fiber ChannelVerify Power-On Self EthernetConnection Test PostDepartmental Switch Model DS-16B Hardware Reference Manual Switch Management Comparing Switch Management Access Methods SESManaging Through Front Panel Buttons Control ButtonsSelect Menu Configuration Menu Activating MenuDisplay Front panel buttons activates the displayDS-16B Switch Menus Following menus are controlled using the front panel buttonsCommands Shows the front panel commands and their equivalentTelnet command Menu Front Panel Telnet Command DefaultUnset QuickLoop Port Configure QuickLoop Partner WWN Cmem Data Retention Test Configuration menu See Configuration MenuRatov Edtov Configuration menu Ethernet IP address 10To enter an IP address Ethernet Subnetmask noneTo update the Fibre Channel’s IP address Fibre Channel IP AddressFibre Channel IP address Fibre Channel SubnetmaskGateway address To enter the gateway addressDomain BBcreditRatov Pressing Enter while Ratov is selected, displays RatovEdtov Pressing Enter while Edtov is selected, displays EdtovOperating Mode Operating modes for the switch areFor the corresponding operating mode Operating modes are determined by the host adapter. The sixVC Link Ctl VC Class 2VC Class 3 VC MulticastVC Priorities 0,1,2,2,2,2,3,3 Reset to Default Accept? Yes NoFrame Collection Method? Bundle/Piling Default values Allows you to select commandsOperation Menu Menu. Pressing Enter while the Operation Menu is selectedSwitch Online Operation Menu Switch OfflineOperation Menu Switch Online Operation Menu Port DisableOperation Menu Port Enable Port Enable Accept? Yes NoOperation Menu Reboot Reboot Accept? Yes NoSwitch Name sw15 Status MenuMenu is informational only you cannot make changes to Status Menu SeeBooted At Sat Sep 19 183420 Worldwide Name 1000606900eFirmware Version Current Date Mon Oct 21 102335Boot Prom Date Jun 12 084829 PST Powered Time 137 daysFlash Date Jun 12 084829 PST Up Time DayModule TypeL Port Throughput 75MB/sTemperature 36 34 37 36 3Temperature Sensor Approximate Locations on MotherboardError Log Selecting Error Log, then pressing Enter, displays Feb 12 084829 Err SENSOR-FAILED-3Licenses Test MenuLicenses 01f Front Panel Diagnostics Front Panel Diagnostics DiagnosticThis section gives a diagnostic overview and discusses OverviewDiagnostic Front FaultRemoving Power Panel DisplaysStatus and Activity Indicators IndicatorsFront Panel LED Port Color and flash speed of each port’s LED, as describedPower-On Diagnostics PostDiagnostic Tests Switch Offline Accept? Yes No Switch Online Accept? Yes NoSystem Memory Test at 0x1021d460 len Offline Tests Offline & Online TestsRelated error messages DIAG-MEMORY, DIAG-MEMSZ Related error messages DIAG-REGERR, DIAG-REGERRUNRSTIf the memory tests OK, the front panel displays 0x10199a10 len 13091456 ramTest passedRelated error messages DIAG-CMBISTRO, DIAG-CMBISRF Central MemTest passedRelated error messages DIAG-INIT, DIAG-PORTDIED Port Loopback Test AbortedSpinSilk Press any button to terminate Push Button Test To exit Specifications Table A-1 shows the switch specifications General SpecificationsSpecifications Description Fabric Management Specifications Table A-2 shows Fabric management specificationsTable A-3 Shows Safety specifications Safety SpecificationsSafety Specifications Switch’s primary operating environments are server roomsSpecification Value Optical PortPower Supply DimensionsRack Mount Dimensions Table Top DimensionsSwitch Support Switch Support Support ToolError Messages Error Message Formats Front PanelMessage Formats Feb 12To display error message from the front panel Diagnostic Error Message Formats Failed test ReplaceError Number Test Name Error Name Error MessageNumbers DIAG-TIMEOUT DIAG-CMBISRTODIAG-CMBISRF DIAG-LCMEMTXDIAG-ERRSTAT Encin DIAG-ERRSTAT CRCDIAG-ERRSTAT Trunc DIAG-ERRSTAT 2LONGDIAG-ERRSTATENCIN DIAG-ERRSTATCRLDIAG-ERRSTATTRUNC DIAG-ERRSTAT2LONGDIAG-PORTSTOPPED Error Message Tables Message Description Probable Cause ActionCMI message received failed bad DIAG-ERRSTAT Asic failure Replace Err#1F26 Message Description Probable Cause FLASH, Badmirror RPC, SvcexitRPC, Svcreg FCIU, IUBAD, L, SFCIU, IUCOUNT, L, S FCPH, EXCHBAD, L, SFCPH, EXCHFREE, L, S MQ, QWRITE, L, MSYS BADPTR, Logerror SYS FLASHRD, LogerrorSYS FLASHWR, Logerror TIMERS, MSG,LOGWARNINGMCAST, Noparentlsr LogerrorUCAST, RRTIM, Logcritical Sales and Service Locations International Sales LocationsDepartmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual Index Index Departmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual