Page 85

 

 

 

 

 

 

Error Messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table C-3

Diagnostic Error Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

Description

Probable Cause

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-LCMTO

 

Central Memory Timeout: Data transfer

ASIC failure

Replace

 

 

 

 

 

Err#1F26, 1026

 

initiated did not complete within the

 

mainboard

 

 

 

 

[centralMemoryTest,

 

timeout period.

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cmemRetentionTest]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-MEMNULL

 

Test failed to malloc.

mainboard failure

Replace

 

 

 

 

 

Err#0112

 

 

 

 

mainboard

 

 

 

 

[ramTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-MEMSZ

 

Memory size to be tested is less than or

mainboard failure

Replace

 

 

 

 

 

Err#0111

 

equal to zero

 

mainboard

 

 

 

 

[ramTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-MEMORY

 

Data read from RAM location did not

CPU RAM failure

Replace

 

 

 

 

 

Err#0110

 

match previously written data into same

 

mainboard

 

 

 

 

[ramTest]

 

location

 

assembly or

 

 

 

 

 

 

 

 

DRAM module

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-PORTABSENT

 

Port is not present

ASIC or mainboard

Replace

 

 

 

 

 

Err#2670, 3070, 3870

 

 

 

failure

mainboard

 

 

 

 

[portLoopbackTest, crossPortTest,

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

spinSilk]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-PORTDIED

 

Port was in loopback mode and then went

ASIC, GBIC module

Replace

 

 

 

 

 

Err#265F, 305F, 385F

 

inactive

or fiber cable failure

mainboard

 

 

 

 

[portLoopbackTest, crossPortTest,

 

 

 

 

assembly, GBIC

 

 

 

 

 

 

 

 

module or fiber

 

 

 

 

 

spinSilk]

 

 

 

 

 

 

 

 

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-PORTSTOPPED

 

Port is no longer transmitting, as indicated

ASIC, GBIC module

Replace

 

 

 

 

 

Err#3874

 

by the Number Of Frames Transmitted

or fiber cable failure

mainboard

 

 

 

 

[spinSilk]

 

counter being stuck at N frames.

 

assembly, GBIC

 

 

 

 

 

 

 

 

module or fiber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-PORTWRONG

 

Frame erroneously received by port M

ASIC failure

Replace

 

 

 

 

 

Err#3078

 

instead of the intended port N

 

mainboard

 

 

 

 

[crossPortTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-POST_SKIPPED

 

POST is skipped. It’s message

Informational Only

None required

 

 

 

 

 

Err# 0004

 

recommended that POST be executed.

 

 

 

 

 

 

 

[switch initialization]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-REGERR

 

Data read from ASIC register or ASIC

ASIC failure

Replace

 

 

 

 

 

Err#0B15, 0415

 

SRAM did not match data previously

 

mainboard

 

 

 

 

[portRegTest, sramRetentionTest]

 

written into same location

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Message Tables

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 85
Contents Hardware Reference Manual Departmental Switch Model DS-16BCopyright 2000 EMC Corporation. All rights reserved Departmental Switch Model DS-16B Hardware Reference Manual Trademark Information FCC Warning USA only Departmental Switch Model DS-16B Hardware Reference Manual Contents Chapter Front Panel Diagnostics Chapter Switch ManagementAppendix a Specifications Appendix B Switch SupportAppendix C Error Messages Departmental Switch Model DS-16B Hardware Reference Manual Figures Figures Preface For Information On See Related Publications Conventions Used in This ManualExamples of specific command entries that you Command line arguments when used in textArguments used in examples of command line Ask for Customer ServiceDepartmental Switch Model DS-16B Hardware Reference Manual Introduction System Components IntroductionFeatures DS-16B SwitchFollowing features IntroductionManageability PerformanceUnit may be managed in band or out of band via Telnet, via Ethernet portFabric Operating System ComponentsSystem GBICsInstallation Unpacking the Switch Site Considerations Power RequirementsCooling RequirementsTo install the adhesive rubber feet Installation ConsiderationsStandalone Fiber ChannelEthernet Verify Power-On SelfConnection Test PostDepartmental Switch Model DS-16B Hardware Reference Manual Switch Management SES Comparing Switch Management Access MethodsControl Buttons Managing Through Front Panel ButtonsActivating Menu Select Menu Configuration MenuDisplay Front panel buttons activates the displayFollowing menus are controlled using the front panel buttons DS-16B Switch MenusShows the front panel commands and their equivalent CommandsTelnet command Menu Front Panel Telnet Command DefaultUnset QuickLoop Port Configure QuickLoop Partner WWN Cmem Data Retention Test Configuration menu See Configuration MenuRatov Edtov Ethernet IP address 10 Configuration menuTo enter an IP address Ethernet Subnetmask noneFibre Channel IP Address To update the Fibre Channel’s IP addressFibre Channel IP address Fibre Channel SubnetmaskTo enter the gateway address Gateway addressDomain BBcreditRatov Ratov Pressing Enter while Ratov is selected, displaysEdtov Pressing Enter while Edtov is selected, displays EdtovOperating modes for the switch are Operating ModeFor the corresponding operating mode Operating modes are determined by the host adapter. The sixVC Class 2 VC Link CtlVC Class 3 VC MulticastVC Priorities 0,1,2,2,2,2,3,3 Reset to Default Accept? Yes NoFrame Collection Method? Bundle/Piling Allows you to select commands Default valuesOperation Menu Menu. Pressing Enter while the Operation Menu is selectedOperation Menu Switch Offline Switch OnlineOperation Menu Switch Online Operation Menu Port DisablePort Enable Accept? Yes No Operation Menu Port EnableOperation Menu Reboot Reboot Accept? Yes NoStatus Menu Switch Name sw15Menu is informational only you cannot make changes to Status Menu SeeWorldwide Name 1000606900e Booted At Sat Sep 19 183420Firmware Version Current Date Mon Oct 21 102335Powered Time 137 days Boot Prom Date Jun 12 084829 PSTFlash Date Jun 12 084829 PST Up Time DayPort Throughput 75MB/s Module TypeL3Temperature Sensor Approximate Locations on Motherboard Temperature 36 34 37 36Feb 12 084829 Err SENSOR-FAILED-3 Error Log Selecting Error Log, then pressing Enter, displaysLicenses Test MenuLicenses 01f Front Panel Diagnostics Diagnostic Front Panel DiagnosticsThis section gives a diagnostic overview and discusses OverviewFault Diagnostic FrontRemoving Power Panel DisplaysIndicators Status and Activity IndicatorsFront Panel LED Port Color and flash speed of each port’s LED, as describedDiagnostics Post Power-OnDiagnostic Tests Switch Online Accept? Yes No Switch Offline Accept? Yes NoSystem Memory Test at 0x1021d460 len Offline Tests Offline & Online TestsRelated error messages DIAG-REGERR, DIAG-REGERRUNRST Related error messages DIAG-MEMORY, DIAG-MEMSZIf the memory tests OK, the front panel displays 0x10199a10 len 13091456 ramTest passedCentral MemTest passed Related error messages DIAG-CMBISTRO, DIAG-CMBISRFPort Loopback Test Aborted Related error messages DIAG-INIT, DIAG-PORTDIEDSpinSilk Press any button to terminate Push Button Test To exit Specifications Table A-1 shows the switch specifications General SpecificationsSpecifications Description Table A-2 shows Fabric management specifications Fabric Management SpecificationsTable A-3 Shows Safety specifications Safety SpecificationsSafety Switch’s primary operating environments are server rooms SpecificationsSpecification Value Optical PortDimensions Power SupplyRack Mount Dimensions Table Top DimensionsSwitch Support Support Tool Switch SupportError Messages Front Panel Error Message FormatsMessage Formats Feb 12To display error message from the front panel Failed test Replace Diagnostic Error Message FormatsError Number Test Name Error Name Error MessageNumbers DIAG-CMBISRTO DIAG-TIMEOUTDIAG-CMBISRF DIAG-LCMEMTXDIAG-ERRSTAT CRC DIAG-ERRSTAT EncinDIAG-ERRSTAT Trunc DIAG-ERRSTAT 2LONGDIAG-ERRSTATCRL DIAG-ERRSTATENCINDIAG-ERRSTATTRUNC DIAG-ERRSTAT2LONGDIAG-PORTSTOPPED Message Description Probable Cause Action Error Message TablesCMI message received failed bad DIAG-ERRSTAT Asic failure Replace Err#1F26 Message Description Probable Cause RPC, Svcexit FLASH, BadmirrorRPC, Svcreg FCIU, IUBAD, L, SFCPH, EXCHBAD, L, S FCIU, IUCOUNT, L, SFCPH, EXCHFREE, L, S MQ, QWRITE, L, MSYS FLASHRD, Logerror SYS BADPTR, LogerrorSYS FLASHWR, Logerror TIMERS, MSG,LOGWARNINGMCAST, Noparentlsr LogerrorUCAST, RRTIM, Logcritical Sales and Service Locations Locations International SalesDepartmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual Index Index Departmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual