EMC DS-16B manual Diag-Errstatencin, Diag-Errstatcrl, Diag-Errstattrunc, DIAG-ERRSTAT2LONG

Page 80

Error Messages

Table C-2Error Message Codes Defined (continued)

Error Number

Test Name

Error Name

 

 

 

 

 

 

3040

crossPortTest

DIAG-ERRSTAT(ENCIN)

 

 

 

3041

 

DIAG-ERRSTAT(CRL)

 

 

 

3042

 

DIAG-ERRSTAT(TRUNC)

 

 

 

3043

 

DIAG-ERRSTAT(2LONG)

 

 

 

3044

 

DIAG-ERRSTAT(BADEOF)

 

 

 

3045

 

DIAG-ERRSTATENCOUT)

 

 

 

3046

 

DIAG-ERRSTAT(BADORD)

 

 

 

3047

 

DIAG-ERRSTAT(DISC3)

 

 

 

304F

 

DIAG-INIT

 

 

 

305F

 

DIAG-PORTDIED

 

 

 

3060

 

DIAG-STATS (FTX)

 

 

 

3061

 

DIAG-STATS (FRX)

 

 

 

3062

 

DIAG-STATS (C3FRX)

 

 

 

306E

 

DIAG-DATA

 

 

 

306F

 

DIAG-TIMEOUT

 

 

 

3070

 

DIAG-PORTABSENT

 

 

 

3071

 

DIAG-XMIT

 

 

 

3078

 

DIAG-PORTWRONG

 

 

 

Departmental Switch Model DS-16B Hardware Reference Manual

Image 80
Contents Departmental Switch Model DS-16B Hardware Reference ManualCopyright 2000 EMC Corporation. All rights reserved Departmental Switch Model DS-16B Hardware Reference Manual Trademark Information FCC Warning USA only Departmental Switch Model DS-16B Hardware Reference Manual Contents Chapter Switch Management Chapter Front Panel DiagnosticsAppendix a Specifications Appendix B Switch SupportAppendix C Error Messages Departmental Switch Model DS-16B Hardware Reference Manual Figures Figures Preface Related Publications Conventions Used in This Manual For Information On SeeCommand line arguments when used in text Examples of specific command entries that youArguments used in examples of command line Ask for Customer ServiceDepartmental Switch Model DS-16B Hardware Reference Manual Introduction Introduction System ComponentsDS-16B Switch FeaturesFollowing features IntroductionPerformance ManageabilityUnit may be managed in band or out of band via Telnet, via Ethernet portSystem Components Fabric OperatingSystem GBICsInstallation Unpacking the Switch Power Requirements Site ConsiderationsCooling RequirementsInstallation Considerations To install the adhesive rubber feetStandalone Fiber ChannelVerify Power-On Self EthernetConnection Test PostDepartmental Switch Model DS-16B Hardware Reference Manual Switch Management Comparing Switch Management Access Methods SESManaging Through Front Panel Buttons Control ButtonsSelect Menu Configuration Menu Activating MenuDisplay Front panel buttons activates the displayDS-16B Switch Menus Following menus are controlled using the front panel buttonsCommands Shows the front panel commands and their equivalentTelnet command Menu Front Panel Telnet Command DefaultUnset QuickLoop Port Configure QuickLoop Partner WWN Cmem Data Retention Test Ratov Edtov Configuration MenuConfiguration menu See Configuration menu Ethernet IP address 10To enter an IP address Ethernet Subnetmask noneTo update the Fibre Channel’s IP address Fibre Channel IP AddressFibre Channel IP address Fibre Channel SubnetmaskGateway address To enter the gateway addressDomain BBcreditRatov Pressing Enter while Ratov is selected, displays RatovEdtov Pressing Enter while Edtov is selected, displays EdtovOperating Mode Operating modes for the switch areFor the corresponding operating mode Operating modes are determined by the host adapter. The sixVC Link Ctl VC Class 2VC Class 3 VC MulticastFrame Collection Method? Bundle/Piling Reset to Default Accept? Yes NoVC Priorities 0,1,2,2,2,2,3,3 Default values Allows you to select commandsOperation Menu Menu. Pressing Enter while the Operation Menu is selectedSwitch Online Operation Menu Switch OfflineOperation Menu Switch Online Operation Menu Port DisableOperation Menu Port Enable Port Enable Accept? Yes NoOperation Menu Reboot Reboot Accept? Yes NoSwitch Name sw15 Status MenuMenu is informational only you cannot make changes to Status Menu SeeBooted At Sat Sep 19 183420 Worldwide Name 1000606900eFirmware Version Current Date Mon Oct 21 102335Boot Prom Date Jun 12 084829 PST Powered Time 137 daysFlash Date Jun 12 084829 PST Up Time DayModule TypeL Port Throughput 75MB/sTemperature 36 34 37 36 3Temperature Sensor Approximate Locations on MotherboardError Log Selecting Error Log, then pressing Enter, displays Feb 12 084829 Err SENSOR-FAILED-3Licenses 01f Test MenuLicenses Front Panel Diagnostics Front Panel Diagnostics DiagnosticThis section gives a diagnostic overview and discusses OverviewDiagnostic Front FaultRemoving Power Panel DisplaysStatus and Activity Indicators IndicatorsFront Panel LED Port Color and flash speed of each port’s LED, as describedPower-On Diagnostics PostDiagnostic Tests Switch Offline Accept? Yes No Switch Online Accept? Yes NoSystem Memory Test at 0x1021d460 len Offline Tests Offline & Online TestsRelated error messages DIAG-MEMORY, DIAG-MEMSZ Related error messages DIAG-REGERR, DIAG-REGERRUNRSTIf the memory tests OK, the front panel displays 0x10199a10 len 13091456 ramTest passedRelated error messages DIAG-CMBISTRO, DIAG-CMBISRF Central MemTest passedRelated error messages DIAG-INIT, DIAG-PORTDIED Port Loopback Test AbortedSpinSilk Press any button to terminate Push Button Test To exit Specifications Specifications Description General SpecificationsTable A-1 shows the switch specifications Fabric Management Specifications Table A-2 shows Fabric management specificationsSafety Safety SpecificationsTable A-3 Shows Safety specifications Specifications Switch’s primary operating environments are server roomsSpecification Value Optical PortPower Supply DimensionsRack Mount Dimensions Table Top DimensionsSwitch Support Switch Support Support ToolError Messages Error Message Formats Front PanelMessage Formats Feb 12To display error message from the front panel Diagnostic Error Message Formats Failed test ReplaceNumbers Error MessageError Number Test Name Error Name DIAG-TIMEOUT DIAG-CMBISRTODIAG-CMBISRF DIAG-LCMEMTXDIAG-ERRSTAT Encin DIAG-ERRSTAT CRCDIAG-ERRSTAT Trunc DIAG-ERRSTAT 2LONGDIAG-ERRSTATENCIN DIAG-ERRSTATCRLDIAG-ERRSTATTRUNC DIAG-ERRSTAT2LONGDIAG-PORTSTOPPED Error Message Tables Message Description Probable Cause ActionCMI message received failed bad DIAG-ERRSTAT Asic failure Replace Err#1F26 Message Description Probable Cause FLASH, Badmirror RPC, SvcexitRPC, Svcreg FCIU, IUBAD, L, SFCIU, IUCOUNT, L, S FCPH, EXCHBAD, L, SFCPH, EXCHFREE, L, S MQ, QWRITE, L, MSYS BADPTR, Logerror SYS FLASHRD, LogerrorSYS FLASHWR, Logerror TIMERS, MSG,LOGWARNINGUCAST, RRTIM, Logcritical LogerrorMCAST, Noparentlsr Sales and Service Locations International Sales LocationsDepartmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual Index Index Departmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual