EMC DS-16B manual CMI message received failed bad

Page 83

 

 

 

 

 

 

Error Messages

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table C-3

Diagnostic Error Messages (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Message

 

Description

Probable Cause

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMICKSUM

 

CMI message received failed bad

ASIC or mainboard

Replace

 

 

 

 

 

Err#2036

 

checksum test.

failure

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMIDATA

 

CMI data received did not match data

ASIC or mainboard

Replace

 

 

 

 

 

Err#2035

 

transmitted

failure

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMIINVCAP

 

Unintended ASIC erroneously got CMI

ASIC or mainboard

Replace

 

 

 

 

 

Err#2034

 

capture flag

failure

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMINOCAP

 

CMI intended receiver ASIC failed to get

ASIC or mainboard

Replace

 

 

 

 

 

Err#2033

 

CMI capture flag.

failure

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMISA1

 

An attempt to send a CMI message from

ASIC failure

Replace

 

 

 

 

 

Err#2032

 

ASIC to ASIC failed.

 

mainboard

 

 

 

 

[cmiTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-CMNOBUF

 

Port could not get any buffer

ASIC failure

Replace

 

 

 

 

 

Err#1029

 

 

 

 

mainboard

 

 

 

 

[centralMemoryTest]

 

 

 

 

assembly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIAG-DATA

 

Payload received by port did not match

mainboard, GBIC

Replace

 

 

 

 

 

Err#266E, 306E

 

payload transmitted.

module or fiber

mainboard

 

 

 

 

[portLoopbackTest, crossPortTest]

 

 

 

cable failure

assembly, GBIC

 

 

 

 

 

 

 

 

module or fiber

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Message Tables

Image 83
Contents Hardware Reference Manual Departmental Switch Model DS-16BCopyright 2000 EMC Corporation. All rights reserved Departmental Switch Model DS-16B Hardware Reference Manual Trademark Information FCC Warning USA only Departmental Switch Model DS-16B Hardware Reference Manual Contents Appendix B Switch Support Chapter Switch ManagementChapter Front Panel Diagnostics Appendix a SpecificationsAppendix C Error Messages Departmental Switch Model DS-16B Hardware Reference Manual Figures Figures Preface For Information On See Related Publications Conventions Used in This ManualAsk for Customer Service Command line arguments when used in textExamples of specific command entries that you Arguments used in examples of command lineDepartmental Switch Model DS-16B Hardware Reference Manual Introduction System Components IntroductionIntroduction DS-16B SwitchFeatures Following featuresEthernet port PerformanceManageability Unit may be managed in band or out of band via Telnet, viaGBICs System ComponentsFabric Operating SystemInstallation Unpacking the Switch Requirements Power RequirementsSite Considerations CoolingFiber Channel Installation ConsiderationsTo install the adhesive rubber feet StandaloneTest Post Verify Power-On SelfEthernet ConnectionDepartmental Switch Model DS-16B Hardware Reference Manual Switch Management SES Comparing Switch Management Access MethodsControl Buttons Managing Through Front Panel ButtonsFront panel buttons activates the display Select Menu Configuration MenuActivating Menu DisplayFollowing menus are controlled using the front panel buttons DS-16B Switch MenusMenu Front Panel Telnet Command Default CommandsShows the front panel commands and their equivalent Telnet commandUnset QuickLoop Port Configure QuickLoop Partner WWN Cmem Data Retention Test Ratov Edtov Configuration MenuConfiguration menu See Ethernet Subnetmask none Configuration menuEthernet IP address 10 To enter an IP addressFibre Channel Subnetmask To update the Fibre Channel’s IP addressFibre Channel IP Address Fibre Channel IP addressBBcredit Gateway addressTo enter the gateway address DomainEdtov Ratov Pressing Enter while Ratov is selected, displaysRatov Edtov Pressing Enter while Edtov is selected, displaysOperating modes are determined by the host adapter. The six Operating ModeOperating modes for the switch are For the corresponding operating modeVC Multicast VC Link CtlVC Class 2 VC Class 3Frame Collection Method? Bundle/Piling Reset to Default Accept? Yes NoVC Priorities 0,1,2,2,2,2,3,3 Menu. Pressing Enter while the Operation Menu is selected Default valuesAllows you to select commands Operation MenuOperation Menu Port Disable Switch OnlineOperation Menu Switch Offline Operation Menu Switch OnlineReboot Accept? Yes No Operation Menu Port EnablePort Enable Accept? Yes No Operation Menu RebootStatus Menu See Switch Name sw15Status Menu Menu is informational only you cannot make changes toCurrent Date Mon Oct 21 102335 Booted At Sat Sep 19 183420Worldwide Name 1000606900e Firmware VersionUp Time Day Boot Prom Date Jun 12 084829 PSTPowered Time 137 days Flash Date Jun 12 084829 PSTPort Throughput 75MB/s Module TypeL3Temperature Sensor Approximate Locations on Motherboard Temperature 36 34 37 36Feb 12 084829 Err SENSOR-FAILED-3 Error Log Selecting Error Log, then pressing Enter, displaysLicenses 01f Test MenuLicenses Front Panel Diagnostics Overview Front Panel DiagnosticsDiagnostic This section gives a diagnostic overview and discussesPanel Displays Diagnostic FrontFault Removing PowerColor and flash speed of each port’s LED, as described Status and Activity IndicatorsIndicators Front Panel LED PortDiagnostics Post Power-OnDiagnostic Tests Offline Tests Offline & Online Tests Switch Offline Accept? Yes NoSwitch Online Accept? Yes No System Memory Test at 0x1021d460 len0x10199a10 len 13091456 ramTest passed Related error messages DIAG-MEMORY, DIAG-MEMSZRelated error messages DIAG-REGERR, DIAG-REGERRUNRST If the memory tests OK, the front panel displaysCentral MemTest passed Related error messages DIAG-CMBISTRO, DIAG-CMBISRFPort Loopback Test Aborted Related error messages DIAG-INIT, DIAG-PORTDIEDSpinSilk Press any button to terminate Push Button Test To exit Specifications Specifications Description General SpecificationsTable A-1 shows the switch specifications Table A-2 shows Fabric management specifications Fabric Management SpecificationsSafety Safety SpecificationsTable A-3 Shows Safety specifications Optical Port SpecificationsSwitch’s primary operating environments are server rooms Specification ValueTable Top Dimensions Power SupplyDimensions Rack Mount DimensionsSwitch Support Support Tool Switch SupportError Messages Feb 12 Error Message FormatsFront Panel Message FormatsTo display error message from the front panel Failed test Replace Diagnostic Error Message FormatsNumbers Error MessageError Number Test Name Error Name DIAG-LCMEMTX DIAG-TIMEOUTDIAG-CMBISRTO DIAG-CMBISRFDIAG-ERRSTAT 2LONG DIAG-ERRSTAT EncinDIAG-ERRSTAT CRC DIAG-ERRSTAT TruncDIAG-ERRSTAT2LONG DIAG-ERRSTATENCINDIAG-ERRSTATCRL DIAG-ERRSTATTRUNCDIAG-PORTSTOPPED Message Description Probable Cause Action Error Message TablesCMI message received failed bad DIAG-ERRSTAT Asic failure Replace Err#1F26 Message Description Probable Cause FCIU, IUBAD, L, S FLASH, BadmirrorRPC, Svcexit RPC, SvcregMQ, QWRITE, L, M FCIU, IUCOUNT, L, SFCPH, EXCHBAD, L, S FCPH, EXCHFREE, L, STIMERS, MSG,LOGWARNING SYS BADPTR, LogerrorSYS FLASHRD, Logerror SYS FLASHWR, LogerrorUCAST, RRTIM, Logcritical LogerrorMCAST, Noparentlsr Sales and Service Locations Locations International SalesDepartmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual Index Index Departmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual