EMC DS-16B manual Cmem Data Retention Test

Page 34

Switch Management

Table 3-3

Front Panel and Telnet Commands (continued)

 

 

 

 

 

 

Menu

 

Front Panel

Telnet Command

Default

 

 

 

 

 

 

 

 

 

 

 

 

Port Throughput

portPerfShow

N/A

 

 

 

 

 

 

 

Temperature

tempShow

N/A

 

 

 

 

 

 

 

Error Log

errShow

N/A

 

 

 

 

 

 

 

Licenses

licenseShow

N/A

 

 

 

 

 

Test

 

Switch Offline

SwitchDisable

N/A

 

 

 

 

 

 

 

Switch Online

SwitchEnable

N/A

 

 

 

 

 

 

 

Memory Test

ramTest

N/A

 

 

 

 

 

 

 

Port Register Test

portRegTest

N/A

 

 

 

 

 

 

 

Central Memory Test

centralMemoryTest

N/A

 

 

 

 

 

 

 

CMI Conn Test

cmiTest

N/A

 

 

 

 

 

 

 

CAM Test

cam Test

N/A

 

 

 

 

 

 

 

Port Loopback Test

portLoopbackTest

N/A

 

 

 

 

 

 

 

Cross Port Test

crossPortTest

N/A

 

 

 

 

 

 

 

Spin Silk Test

spinSilk

N/A

 

 

 

 

 

 

 

SRAM Data Retention Test

sramRetentionTest

N/A

 

 

 

 

 

 

 

CMEM Data Retention Test

cmemRetentionTest

N/A

 

 

 

 

 

 

 

Display Test

N/A

N/A

 

 

 

 

 

 

 

Push-Button Test

N/A

N/A

 

 

 

 

 

Departmental Switch Model DS-16B Hardware Reference Manual

Image 34
Contents Departmental Switch Model DS-16B Hardware Reference ManualCopyright 2000 EMC Corporation. All rights reserved Departmental Switch Model DS-16B Hardware Reference Manual Trademark Information FCC Warning USA only Departmental Switch Model DS-16B Hardware Reference Manual Contents Appendix a Specifications Chapter Switch ManagementChapter Front Panel Diagnostics Appendix B Switch SupportAppendix C Error Messages Departmental Switch Model DS-16B Hardware Reference Manual Figures Figures Preface Related Publications Conventions Used in This Manual For Information On SeeArguments used in examples of command line Command line arguments when used in textExamples of specific command entries that you Ask for Customer ServiceDepartmental Switch Model DS-16B Hardware Reference Manual Introduction Introduction System ComponentsFollowing features DS-16B SwitchFeatures IntroductionUnit may be managed in band or out of band via Telnet, via PerformanceManageability Ethernet portSystem System ComponentsFabric Operating GBICsInstallation Unpacking the Switch Cooling Power RequirementsSite Considerations RequirementsStandalone Installation ConsiderationsTo install the adhesive rubber feet Fiber ChannelConnection Verify Power-On SelfEthernet Test PostDepartmental Switch Model DS-16B Hardware Reference Manual Switch Management Comparing Switch Management Access Methods SESManaging Through Front Panel Buttons Control ButtonsDisplay Select Menu Configuration MenuActivating Menu Front panel buttons activates the displayDS-16B Switch Menus Following menus are controlled using the front panel buttonsTelnet command CommandsShows the front panel commands and their equivalent Menu Front Panel Telnet Command DefaultUnset QuickLoop Port Configure QuickLoop Partner WWN Cmem Data Retention Test Configuration menu See Configuration MenuRatov Edtov To enter an IP address Configuration menuEthernet IP address 10 Ethernet Subnetmask noneFibre Channel IP address To update the Fibre Channel’s IP addressFibre Channel IP Address Fibre Channel SubnetmaskDomain Gateway addressTo enter the gateway address BBcreditEdtov Pressing Enter while Edtov is selected, displays Ratov Pressing Enter while Ratov is selected, displaysRatov EdtovFor the corresponding operating mode Operating ModeOperating modes for the switch are Operating modes are determined by the host adapter. The sixVC Class 3 VC Link CtlVC Class 2 VC MulticastVC Priorities 0,1,2,2,2,2,3,3 Reset to Default Accept? Yes NoFrame Collection Method? Bundle/Piling Operation Menu Default valuesAllows you to select commands Menu. Pressing Enter while the Operation Menu is selectedOperation Menu Switch Online Switch OnlineOperation Menu Switch Offline Operation Menu Port DisableOperation Menu Reboot Operation Menu Port EnablePort Enable Accept? Yes No Reboot Accept? Yes NoMenu is informational only you cannot make changes to Switch Name sw15Status Menu Status Menu SeeFirmware Version Booted At Sat Sep 19 183420Worldwide Name 1000606900e Current Date Mon Oct 21 102335Flash Date Jun 12 084829 PST Boot Prom Date Jun 12 084829 PSTPowered Time 137 days Up Time DayModule TypeL Port Throughput 75MB/sTemperature 36 34 37 36 3Temperature Sensor Approximate Locations on MotherboardError Log Selecting Error Log, then pressing Enter, displays Feb 12 084829 Err SENSOR-FAILED-3Licenses Test MenuLicenses 01f Front Panel Diagnostics This section gives a diagnostic overview and discusses Front Panel DiagnosticsDiagnostic OverviewRemoving Power Diagnostic FrontFault Panel DisplaysFront Panel LED Port Status and Activity IndicatorsIndicators Color and flash speed of each port’s LED, as describedPower-On Diagnostics PostDiagnostic Tests System Memory Test at 0x1021d460 len Switch Offline Accept? Yes NoSwitch Online Accept? Yes No Offline Tests Offline & Online TestsIf the memory tests OK, the front panel displays Related error messages DIAG-MEMORY, DIAG-MEMSZRelated error messages DIAG-REGERR, DIAG-REGERRUNRST 0x10199a10 len 13091456 ramTest passedRelated error messages DIAG-CMBISTRO, DIAG-CMBISRF Central MemTest passedRelated error messages DIAG-INIT, DIAG-PORTDIED Port Loopback Test AbortedSpinSilk Press any button to terminate Push Button Test To exit Specifications Table A-1 shows the switch specifications General SpecificationsSpecifications Description Fabric Management Specifications Table A-2 shows Fabric management specificationsTable A-3 Shows Safety specifications Safety SpecificationsSafety Specification Value SpecificationsSwitch’s primary operating environments are server rooms Optical PortRack Mount Dimensions Power SupplyDimensions Table Top DimensionsSwitch Support Switch Support Support ToolError Messages Message Formats Error Message FormatsFront Panel Feb 12To display error message from the front panel Diagnostic Error Message Formats Failed test ReplaceError Number Test Name Error Name Error MessageNumbers DIAG-CMBISRF DIAG-TIMEOUTDIAG-CMBISRTO DIAG-LCMEMTXDIAG-ERRSTAT Trunc DIAG-ERRSTAT EncinDIAG-ERRSTAT CRC DIAG-ERRSTAT 2LONGDIAG-ERRSTATTRUNC DIAG-ERRSTATENCINDIAG-ERRSTATCRL DIAG-ERRSTAT2LONGDIAG-PORTSTOPPED Error Message Tables Message Description Probable Cause ActionCMI message received failed bad DIAG-ERRSTAT Asic failure Replace Err#1F26 Message Description Probable Cause RPC, Svcreg FLASH, BadmirrorRPC, Svcexit FCIU, IUBAD, L, SFCPH, EXCHFREE, L, S FCIU, IUCOUNT, L, SFCPH, EXCHBAD, L, S MQ, QWRITE, L, MSYS FLASHWR, Logerror SYS BADPTR, LogerrorSYS FLASHRD, Logerror TIMERS, MSG,LOGWARNINGMCAST, Noparentlsr LogerrorUCAST, RRTIM, Logcritical Sales and Service Locations International Sales LocationsDepartmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual Index Index Departmental Switch Model DS-16B Hardware Reference Manual Departmental Switch Model DS-16B Hardware Reference Manual