Extron electronic ISM 482 manual Host-to-Switcher Instructions, Switcher error responses

Page 54

Aut X3

The Auto Presets feature has been turned on or off from the front panel for all tie creations. X3 is the on/off status.

1Enh X19

The enhanced mode feature has been turned on or off from the front panel for S-video or composite video that is tied to one or both outputs. X19 is the on/off status for the two outputs. The leading “1” is meaningless.

X2 Reconfig

The input selected for the X2 output has been adjusted using the Auto Image feature or a user preset.

Host-to-Switcher Instructions

The switcher accepts SIS commands through its RS-232 port and/or its Ethernet port. SIS commands consist of one or more characters per command field. They do not require any special characters to begin or end the command character sequence. Each switcher response to an SIS command ends with a carriage return and a line feed (CR/LF = ), which signals the end of the response character string. A string is one or more characters.

Switcher error responses

When the switcher receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the switcher is unable to perform the command because the command is invalid or contains invalid parameters, the switcher returns an error response to the host. The error response codes are:

E01 — Invalid input channel number (too large)

E10 — Invalid command

E11 — Invalid preset number (zero or too large)

E12 — Invalid output number (zero or too large)

E13 — Invalid value (out of range)

Using the command/response table

The command/response table begins on the next page. Except for the gain and attenuation settings and the filter settings, upper or lower case letters are acceptable in the command field. Command and response examples are shown throughout the table.

The table below shows the hexadecimal equivalent of each ASCII command.

With the exception of the audio gain and attenuation (G and g) and horizontal

 

and vertical filtering (D and d)

ASCII to HEX Conversion Table

commands, the SIS commands

Space

are not case sensitive.

Integration Scaling Matrix Switcher • Programmer’s Guide

4-7

Image 54
Contents ISM Precautions FCC Class B Notice Quick Start Integration Scaling Matrix Switcher Integration Scaling Matrix Switcher Quick Start QS-1Quick Start Integration Scaling Matrix Switcher, cont’d QS-2 Integration Scaling Matrix Switcher Quick StartTable of Contents Table of Contents, cont’d Integration Scaling Matrix Switcher Table of Contents Iii Iv Integration Scaling Matrix Switcher Table of Contents One Introductiontroduction, cont’d About the SwitcherIntegration Scaling Matrix Switcher Introduction About this ManualExtron ISM Introduction, cont’d Integration Scaling Matrix Switcher Introduction Introduction, cont’d Two Tabletop placement Installationstallation, cont’dMounting the Switcher Rack mountingMounting the switcher Mounting instructionsInstallation, cont’d Cabling and Rear Panel ViewsInput connections Captive screw connector wiring for inputs Standard output connections BNC output connections for Rgbhv and Rgbs videoOptional output connection Cabling and RJ-45 connector wiring Wiring the network cableChoosing a network cable Configuration RS-232 connectionInstallation, cont’d Three Operationeration, cont’d Front Panel Controls and IndicatorsIntegration Scaling Matrix Switcher Operation Video/Audio selection button and LEDsOutput buttons and LEDs Input buttons, LEDs, and label windowFront panel input label window Picture adjustment buttons Operation, cont’dBlack/Mute button and LEDs Adjustment knobs LCD displayMenu control buttons Power Front Panel OperationsMenu system overview Extron Electronics ISM 60-425-01 VersionVideo & Audio Configuration menu Input Configuration submenuOutput Configuration menu Output Resolution submenuOperation, cont’d 10 Advanced Configuration menu flowchart Test Pattern submenu Blue-Only Mode and Edge Smoothing submenuRGB Delay submenu Blanking submenuPAL Film Mode submenu Enhanced Mode submenuPixel Phase submenu Reset submenuUser Presets menu Save Preset submenuErase Preset submenu Exit menuPicture adjustments 13 Picture adjustments flowchartFront panel security lockout Executive mode Adjust knobs have no mechanical limits to their rotationOptimizing the Video IP informationSetting up a DVD source Centering controls to position the imageTroubleshooting Optimizing the AudioGeneral checks Specific problems Problem CauseOperation, cont’d Four Integration Scaling Matrix Switcher Programmer’s Guide RS-232 LinkEthernet Link Symbols Default addressEthernet connection Programmer’s Guide, cont’d Switcher-Initiated MessagesPower-up Ties creationX2 Col Automated adjustments RGB delayPAL film mode Test patternHost-to-Switcher Instructions Switcher error responsesUsing the command/response table Programmer’s Guide, cont’d Command/response table for SIS commands cont’d Command Ascii Command Response Additional descriptionHorizontal detail filter RGB and component video inputs User presets Verbose mode Command/response table for IP SIS commands ResetsCommand/response table for special function SIS commands Command/response table for IP SIS commandsX2 Reconfig message may not be Command/response table for advanced instruction set commands Command Hex Command ResponseFive Installing the software Integration Scaling Matrix Switcher Switcher SoftwareControl Software for Windows Ethernet protocol settings Software operation via EthernetSwitcher Software, cont’d Using the control programWindows Control program window Using the help program Button-Label GeneratorUsing the software To run the Button-Label Generator program, click StartSwitcher Software, cont’d Six Integration Scaling Matrix Switcher Ethernet Operation EthernetOperation,cont’dLoading the Startup Control Control Control Changing the RGB delayEthernet Operation, cont’d Creating a tieFreezing the output Using Blue-Only modeExecutive mode Outputting a test patternSystem Configuration System ConfigurationISM IP Address field Administration fieldsISM IP Settings fields ISM Name fieldFile Management File ManagementInput configuration I/O ConfigurationEthernet Operation, cont’d Output resolution Output rateOutput format Output polaritySeven Maintenance and Modifications Opening and Closing the SwitcherGrounding wrist strap is recommended Maintenance and Modifications, Cont’d Installing a Firmware UpgradeInstalling a DVI Output Card DVI output card connector opening and socket J14Output DVI board installation AAppendix a Integration Scaling Matrix Switcher Ethernet Connection Ethernet ConnectionCabling Determining Default Addresses Pinging to determine the switcher’s IP addressPinging to determine the Web IP address Telnet tips Connecting as a Telnet ClientEthernet Connection, cont’d OpenSet carriage return-line feed Escape character and Esc keyLocal echo CloseEthernet Connection, cont’d AppendixBB Reference Information Audio Reference Information, cont’d Button Labels Reference Information, cont’d Integration Scaling Matrix Switcher Reference Information Reference Information, cont’d Extron’s Warranty Extron Electronics, Europe Beeldschermweg 6C