AEG ARE I2 manual Final Assembly of the Cable Pipe, Plug in of the SAB Cab

Page 11

Manual

Page 11 / 33- Revision 01

ARE I2 / RS 232 – Installation Guide

4.3.5Final Assembly of the Cable Pipe

Pull by and by all the cable back, until the isolation of the cables are near to beginning of the cable pipes.

Fasten nuts (5) of the cable pipes with the right tool (17mm).

Do this carefully, to ensure the tightness of the protection class of IP 65..

Plug the finished assembled MINI-COMBICON-Connector to the SAB Cab. Take care of the correct coding ((7) in Figure 4-2) of the connectors.

4.3.6Plug in of the SAB Cab

Attention:

Before plugging the SAB Cab to the connectors of the reader, make sure that the grounding of the device is well done. Otherwise the electronic may be destroyed by elec- trostatic discharge (ESD).

1

B

A 2

Figure 4-3: Plug on the SAB Cab

Put on the sealing 2 to the SAB Cab (A).

Plug in the SAB Cab to the connector at the bottom of the reader device (B).

There is only one way to plug in the SAB Cab to the connector rim of the reader.

Fasten the SAB Cab with the help of the screws.

AEG

Identifikationssysteme GmbH

Söflinger Straße 100 D-89077 Ulm

Tel. ++49(0)731-933-1340/1877 Fax ++49(0)731-933-1855e-mail: info@AEGID.de

Image 11
Contents Page Introduction System Overview START-UP Procedure Installation Appendix 4 / 33- Revision System Overview IntroductionStart-up Procedure Grounding of the Reader InstallationMounting of the Housing Assemblage of the Line Connectors Assembling of the Cable Pipe Allowed Diameter of the Used CablesArranged Parts for Mounting Mounting of the Power Supply CableAre Plug in of the SAB Cab Final Assembly of the Cable PipeRS232 Using the Service Cable IDPower Supply Using the Power Supply and Data Cable IDAre Visual Signal LampsGeneral Settings of the Reader / Most Important ParametersCID Suppression of ID Codes Error CodesNID- Failure Protection CN Suppression of No ReadsCID=1 BD- Baudrate EC- EchoVsave Save Parameter TOR Maximum Reading TimeVS- Show Parameter Operating Modes of the Reader Mode 2 Triggered by an Software Command22 / 33- Revision Settings of the Reader / Most Used ParametersStandard Read Process / Serial Number of the Transponder GT Basic Data Exchange ProcessReadOnly-Transponder 4 R / W -TransponderWriting Process WD Selective Read RDResponse of the transponder was not readable Continuous operation Operating Mode 0 Continuous Reading27 / 33- Revision General Instructions InstructionsSpecial Instructions for Using a Read / Write System Revisions HotlineReference Documentation Appendix Best Orientation for an F-Type -Reader Best Orientation for an L-Type -Reader Assembling of the SAB Cab