ARE I2 / RS 232 – Installation Guide
Input format: | CID <SP> parameter <CR> | |
Parameter: |
|
|
|
|
|
| Value | Function |
| 0 | no filter function , (default value) |
| 1 | suppression of repeatedly read IDs |
Please note: The CID parameter is only active, if the
6.4CN – Suppression of No Reads
Through the setting CN=1 all NoRead results are suppressed on the serial interface..
Input format: | CN <SP> parameter <CR> | |
Parameter: |
|
|
|
|
|
| Value | Function |
| 0 | issue NoReads on serial interface; (default value) |
| 1 | suppress NoReads on interface |
Output (example): 0 <CR>
Please note: The CN parameter is only active, if the
6.5NID- Failure Protection
NID specifies the number of identical transponder numbers, which have to appear for the result “successful reading“ within a reading cycle. In the setting NID = 1, two successive readings have to show the same transponder number.
Input format: | NID <SP> parameter <CR> |
Parameter: |
|
Value
Function