Page 18 / 33- Revision 01
ARE I2 / RS 232 – Installation Guide
0
1
one out of one (no effect)
two out of two ; (default value)
Output (example): | 1 <CR> |
| |
|
|
|
|
Sequence of readings |
| Length of the reading cycle | Result of the reading cycle |
NoRead |
| 1 reading | NoRead |
0000125ED1, 0000125ED1 |
| 2 readings | 0000125ED1 |
0000125ED1, 0000126ED1 |
| 2 readings | NoRead |
Schedule
Example: A, B, C are specific different transponder numbers, N is NoRead:
Sequence of reading cycles | Output sequence after | Output sequence after |
| filtering with CN=0 and | filtering with CN=1 and |
| CID=1 | CID=1 |
N, N, ......,N, A, A, A, ....A, N,N, | N, N, ......,N, A, N, N, | A |
| ....... |
|
N. N, N, A, A, A, N, A, A, B, A, C, C, C, | N. N, N, A, N, B, A, C, | A, B, A, C |
| ..... |
|
N, N, B, B, B, B, B, N, N, N, B, B, B, B, N, | N, N, B, N, N, N, N, N,... | B |
N,... |
|
|
N, N, N, B, B, B, B, B, N, B, B, B, B, N, N, N, | N, N, N, B, N, N, N, N, | B |
.... | .... |
|
Table 6-: example for the effect of the CID function
Annotation: | The internal reference number is deleted in the following conditions: |
| • after a cold start |
| • after a warm start |
| • after entering the command line CID <SP> 1 <CR> |
| This causes that the next transponder code is output definitely. |
Caution: | The filter function CID picks up the results of the complete reading |
| cycles, while the parameter NID proceeds from the results of single |
| readings! The filter function CID has effect on the serial interface |
| only. |