Page 20 / 33- Revision 01
ARE I2 / RS 232 – Installation Guide
6.8TOR – Maximum Reading Time
Timeout for the reader. TOR is used in operation mode 2 as maximum gating time for a reading process . The length of the maximum gating time results from the equation gat- ing_time = TOR * TB.
The time constant TB (Time Base) has always the default value 100ms.
Input format: | TOR <SP> parameter <CR> |
Parameter: |
|
Function
0limits the reading process duration to exactly one reading cycle
1limits the reading process duration to maximum 1 times TB
2limits the reading process duration to maximum 2 times TB
...
255limits the reading process duration to maximum 256 times TB Output (example): 2 <CR>
6.9VS- Show Parameter
The command VS lists all current parameter settings.
Input format: | VS <CR> |
Output (example): | EC <SP> 0 <CR> |
| BD <SP> 2 <CR> |
MD <SP> 2 <CR> |
|
6.10 VSAVE – Save Parameter
All operating parameters temporarily stored are saved permanently using VSAVE.
Input format: | VSAVE <CR> |
Output: | ok <CR> |