7.1.2 Basic Data Exchange Process

The master has to send an software command to start an read or write process of the reader. After doing all the necessary work at the readers site, the result of the reading or writing proc- ess or an failure code is sent back to the master.

If there is used an read/write transponder, only the serial number of the transponder will be read if the basic read command „Get Tag“ („GT <CR>“) is applied.

The data exchange of the whole memory can only be done, if the reader is set to the Mode 2 ( „selective Read (RD) “ and „write (WD)“).

7.1.3ReadOnly-Transponder

Start the reader with the command GT (plus <CR>)

Wait for the answer( max. time to wait is given by the value of TOR Parameter)

Analyse the received answer:10 characters plus <CR>

The reading result may also been judged according the LED’s.

LED L2 lit, if there was a successful read.

LED L3 lit, if there was a No Read.

7.1.4R / W –Transponder

7.1.4.1 Standard Read Process / Serial Number of the Transponder GT

Start the reader with the command GT (plus <CR>)

Wait for the answer( max. time to wait is given by the value of TOR Parameter)

Analyse the received answer: 8 characters plus <CR>

The reading result may also been judged according the LED’s.

LED L2 lit, if there was a successful read.

LED L3 lit, if there was a No Read.

AEG

Identifikationssysteme GmbH

Söflinger Straße 100 D-89077 Ulm

Tel. ++49(0)731-933-1340/1877 Fax ++49(0)731-933-1855e-mail: info@AEGID.de

Image 23
Contents Page Introduction System Overview START-UP Procedure Installation Appendix 4 / 33- Revision System Overview IntroductionStart-up Procedure Grounding of the Reader InstallationMounting of the Housing Assemblage of the Line ConnectorsAssembling of the Cable Pipe Allowed Diameter of the Used CablesArranged Parts for Mounting Mounting of the Power Supply CableAre Plug in of the SAB Cab Final Assembly of the Cable PipeRS232 Using the Service Cable IDPower Supply Using the Power Supply and Data Cable IDAre Visual Signal LampsGeneral Settings of the Reader / Most Important ParametersCID Suppression of ID Codes Error CodesNID- Failure Protection CN Suppression of No ReadsCID=1 BD- Baudrate EC- EchoVsave Save Parameter TOR Maximum Reading TimeVS- Show Parameter Operating Modes of the Reader Mode 2 Triggered by an Software Command22 / 33- Revision Settings of the Reader / Most Used ParametersStandard Read Process / Serial Number of the Transponder GT Basic Data Exchange ProcessReadOnly-Transponder 4 R / W -TransponderWriting Process WD Selective Read RDResponse of the transponder was not readable Continuous operation Operating Mode 0 Continuous Reading27 / 33- Revision General Instructions InstructionsSpecial Instructions for Using a Read / Write System Revisions HotlineReference Documentation Appendix Best Orientation for an F-Type -Reader Best Orientation for an L-Type -Reader Assembling of the SAB Cab