AEG ARE I2 manual EC- Echo, BD- Baudrate

Page 19

Manual

Page 19 / 33- Revision 01

ARE I2 / RS 232 – Installation Guide

6.6EC- Echo

The command EC changes of the echo function setting.

Input format:

EC <SP> parameter <CR>

Parameter:

 

 

 

 

 

 

 

 

 

 

 

 

v

 

Function

 

 

 

0

 

echo on

 

 

 

1

 

echo off

 

Output (example):

0 <CR>

 

 

Note:

The default value of the parameter EC depends on the particular

 

 

reader.

 

 

6.7BD- Baudrate

The command BD enables the change of the baud rate. The settings are effective after a warm start using the RST command.

Input format:

BD <SP> parameter <CR>

Parameter:

 

 

 

 

 

 

Parame-

Function

 

ter

 

 

 

 

 

0

4800 baud

 

1

9600 baud

 

2

19200 baud

Output (example): 2 <CR>

AEG

Identifikationssysteme GmbH

Söflinger Straße 100 D-89077 Ulm

Tel. ++49(0)731-933-1340/1877 Fax ++49(0)731-933-1855e-mail: info@AEGID.de

Image 19
Contents Page Introduction System Overview START-UP Procedure Installation Appendix 4 / 33- Revision System Overview IntroductionStart-up Procedure Grounding of the Reader InstallationMounting of the Housing Assemblage of the Line ConnectorsAssembling of the Cable Pipe Allowed Diameter of the Used CablesArranged Parts for Mounting Mounting of the Power Supply CableAre Plug in of the SAB Cab Final Assembly of the Cable PipeRS232 Using the Service Cable IDPower Supply Using the Power Supply and Data Cable IDAre Visual Signal LampsGeneral Settings of the Reader / Most Important ParametersCID Suppression of ID Codes Error CodesNID- Failure Protection CN Suppression of No ReadsCID=1 BD- Baudrate EC- EchoVS- Show Parameter TOR Maximum Reading TimeVsave Save Parameter Operating Modes of the Reader Mode 2 Triggered by an Software Command22 / 33- Revision Settings of the Reader / Most Used ParametersStandard Read Process / Serial Number of the Transponder GT Basic Data Exchange ProcessReadOnly-Transponder 4 R / W -TransponderWriting Process WD Selective Read RDResponse of the transponder was not readable Continuous operation Operating Mode 0 Continuous Reading27 / 33- Revision General Instructions InstructionsSpecial Instructions for Using a Read / Write System Reference Documentation HotlineRevisions Appendix Best Orientation for an F-Type -Reader Best Orientation for an L-Type -Reader Assembling of the SAB Cab