Switches, Indicator Lights

& Other Features

(See Diagram 9, p. 35 to locate the following switches, indicator lights and other features.)

Switches

1. Operating Mode Switch (All models)

This switch selects the APS operating mode (either "AUTO/REMOTE", "OFF" or "CHARGE ONLY"). See "Set Operating Mode Switch", pg. 9 to select the optimum setting for this switch.

2. “CONFIGURATION SWITCHES”—DIP Switch Group A (All models)

These four switches must be set for the type of battery your APS will be connected to and the voltage points at which your APS will switch to battery power. See "Configuration", pg.5 to select the optimum settings for these switches.

3. “CONFIGURATION SWITCHES”—DIP Switch Group B (Select models only)

These DIP Switches allow you to equalize the internal resistance of your battery's cells and set the percentage of your model's maximum load at which the APS will limit battery charging. See "Configuration", pg. 6 to select the optimum settings for these switches.

Indicator Lights

4. “LINE” (All models)

This green light will turn continuously ON whenever connected equipment is receiving utility- supplied AC power and your APS is set to "AUTO/REMOTE", meaning that it will provide battery backup if utility power fails. It will flash intermittently when connected equipment is receiving utility power and your APS's Operating Mode Switch is set to "CHARGE ONLY" to warn you that the APS's inverter is OFF and that the APS WILL NOT provide battery backup during blackouts, brownouts or overvoltages.

5. “INV” (Inverting—all models)

This yellow light will turn continuously ON whenever connected equipment is receiving battery- supplied AC power (during a blackout, brownout or overvoltage while connected to utility power or when connected to batteries during vehicular operation).

6. “LOAD” (All models)

This red light will turn continuously ON when the APS’s load is between 80% and 110% of capacity. The light will flash intermittently when the APS's inverter shuts down due to a severe overload or overheating. If this happens, turn Operating Mode Switch OFF. Remove the overload and let the unit cool. You may then turn the APS ON again after it cools.

7. “CUT/BOOST” (VRI models only)

These lights will turn ON whenever your APS is automatically correcting high (CUT) or low (BOOST) AC line voltage. This is a normal, automatic operation of your APS that does not drain battery power, and no action is required on your part.

10

9906058 230V APS MV-cabinet--English.p65 10

 

 

 

3/21/00, 4:29 PM

Image 10
Contents Configuration & Connection p APS 3636VRIIntroduction Load Sharing Select models only Advanced, 3-Stage Battery ChargerVoltage Regulation Select models only Frequency-Controlled Inverter OutputAPS Location Warnings SafetyBattery Connection Warnings Equipment Connection WarningsSelect Battery Type ConfigurationDIP Switch Group a All models Select High AC Switch To Battery Voltage PointEqualize Battery Charge DIP Switch Group B Available on Select ModelsLoad Sharing Selecting Battery Amp Hour Capacity Battery SelectionSelecting Battery Type Permanent Mounting OptionalUse the Shortest and Heaviest Gauge battery cabling Battery Connection StandardBattery Connection DC Vehicular AC ConnectionSee Diagram 3, p Hardwired Electrical ConnectionsSet Operating Mode Switch AC Input Electrical ConnectionSwitches Switches, Indicator Lights Other FeaturesIndicator Lights Other Features Maintenance Maintenance & ServiceLimited Warranty ServiceTroubleshooting Symptom Problems CorrectionsSpecifications-Corded Models InverterSpecifications-Hardwired Models Configuración y Conexión p Introducción Compartición de Carga Modelos selectos solamente Cargador Avanzado De 3 Etapas para BateríasRegulación Automática de Voltaje Modelos Selectos Solamente Inversor con Salida de Frecuencia ControladaPrecauciones Sobre la Conexión de Baterías SeguridadPrecauciones sobre la Ubicación del APS Precauciones Sobre la Conexión de EquiposConfiguración Seleccione el Tipo de BateríasGrupo B DE Interruptores DIP Modelos Selectos Compartición de CargaSeleccione la Capacidad en Amperios/Hora de las Baterías Selección de BateríasIgualar la Carga de Baterías PasoInstalación Permanente Opcional Escoja la configuración apropiada a sus bateríasVea el Diagrama 2 en la página Conexión de Baterías EstándarConexión de CA Conexión de Baterías DC VehículosConexiones Eléctricas Directas al Circuito Conexión de la Entrada Eléctrica de CA Regule el Interruptor Operating Mode Modo de OperaciónConexión de la Salida Eléctrica de CA Interruptores Luces IndicadorasTerminales de Entrada de CD Todos los modelos Otras CaracterísticasLuz Indicadora Capacidad Conector para el Módulo de Control Remoto Todos los modelosMantenimiento Servicio en MéxicoServicio Garantía Limitada Resolución de Problemas Especificaciones InversorModelos CON Toma Directa AL Circuito APS2424 INT APS3636 VRI Diagrams/Esquemas Volts 12V 93-1425 9906057 03/00