Tripp Lite APS2424INT, APS2012INT, APS1024INT owner manual Specifications-Corded Models, Inverter

Page 14

Specifications—Corded Models

CORDED MODELS:

APS 912 INT

APS 1024 INT

Weight:

11.9Kg

11.9Kg

INVERTER

 

 

Continuous power (@ 20° C):

900W

1000W

Surge power (5 seconds):

1800W

2000W

Efficiency (Full Load):

89%

89%

Minimum DC Fuse Rating:

170A

90A

DC Input Current @ Nominal V DC

 

 

Full Load :

85A

47A

No Load :

2.6A*

1.5A*

Nominal DC Input:

12 VDC

24 VDC

DC Input Voltage Range:

10-15 VDC

20-30 VDC

Nominal Output Volts:

230 VAC ± 5%

230 VAC ± 5%

Nominal Output Frequency:

50 Hz

50 Hz

BATTERY CHARGER

 

 

Charging Capacity DC:

30A

15A

Acceptance Volts DC:

Selectable

Selectable:

 

14.4V/14.2VWet/Gel

28.8V/28.4VWet/Gel

Float Volts VDC:

13.3V Wet/13.6V Gel

26.6V Wet/27.2V Gel

Input Voltage AC:

230V

230V

Input Current AC:

4.3A

4.3A

LINE VAC OPERATION

 

 

Minimum Input AC Volts:

Selectable:

Selectable:

 

144**, 163, 182, or 201VAC

144**, 163, 182, or 201VAC

Maximum Input AC Volts:

Selectable: 259** or 264 VAC

Selectable: 259** or 264 VAC

Maximum Input Current

 

 

(Continuous, Charger at Maximum):

8.3A

8.8A

Input Frequency:

45-55 Hz

45-55 Hz

Maximum Output AC (Continuous):

3.9A

4.3A

Automatic Transfer Time:

4-6 ms

4-6 ms

*Load sense can reduce this to 1/30 of the listed current. **Factory default setting. ***When AVR is boosting incoming current.

14

9906058 230V APS MV-cabinet--English.p65 14

 

 

 

3/21/00, 4:29 PM

Image 14
Contents Configuration & Connection p APS 3636VRIIntroduction Load Sharing Select models only Advanced, 3-Stage Battery ChargerVoltage Regulation Select models only Frequency-Controlled Inverter OutputAPS Location Warnings SafetyBattery Connection Warnings Equipment Connection WarningsSelect Battery Type ConfigurationDIP Switch Group a All models Select High AC Switch To Battery Voltage PointLoad Sharing DIP Switch Group B Available on Select ModelsEqualize Battery Charge Selecting Battery Amp Hour Capacity Battery SelectionSelecting Battery Type Permanent Mounting OptionalUse the Shortest and Heaviest Gauge battery cabling Battery Connection StandardBattery Connection DC Vehicular AC ConnectionSee Diagram 3, p Hardwired Electrical ConnectionsSet Operating Mode Switch AC Input Electrical ConnectionIndicator Lights Switches, Indicator Lights Other FeaturesSwitches Other Features Maintenance Maintenance & ServiceLimited Warranty ServiceTroubleshooting Symptom Problems CorrectionsSpecifications-Corded Models InverterSpecifications-Hardwired Models Configuración y Conexión p Introducción Compartición de Carga Modelos selectos solamente Cargador Avanzado De 3 Etapas para BateríasRegulación Automática de Voltaje Modelos Selectos Solamente Inversor con Salida de Frecuencia ControladaPrecauciones Sobre la Conexión de Baterías SeguridadPrecauciones sobre la Ubicación del APS Precauciones Sobre la Conexión de EquiposConfiguración Seleccione el Tipo de BateríasGrupo B DE Interruptores DIP Modelos Selectos Compartición de CargaSeleccione la Capacidad en Amperios/Hora de las Baterías Selección de BateríasIgualar la Carga de Baterías PasoInstalación Permanente Opcional Escoja la configuración apropiada a sus bateríasVea el Diagrama 2 en la página Conexión de Baterías EstándarConexiones Eléctricas Directas al Circuito Conexión de Baterías DC VehículosConexión de CA Conexión de la Salida Eléctrica de CA Regule el Interruptor Operating Mode Modo de OperaciónConexión de la Entrada Eléctrica de CA Interruptores Luces IndicadorasTerminales de Entrada de CD Todos los modelos Otras CaracterísticasLuz Indicadora Capacidad Conector para el Módulo de Control Remoto Todos los modelosServicio Servicio en MéxicoMantenimiento Garantía Limitada Resolución de Problemas Especificaciones InversorModelos CON Toma Directa AL Circuito APS2424 INT APS3636 VRI Diagrams/Esquemas Volts 12V 93-1425 9906057 03/00