Specifications—Hardwired Models

HARDWIRED MODELS:

APS 2012 INT

APS 2424 INT

Weight:

17.1Kg

18.5Kg

INVERTER

 

 

Continuous power (@ 20° C):

2000W

2400W

Surge power (5 seconds):

4000W

4800W

Efficiency (Full Load):

89%

89%

Minimum DC Fuse Rating:

370A

220A

DC Input Current @ Nominal V DC

 

 

Full Load :

187A

112A

No Load :

3A*

1.8A*

Nominal DC Input:

12 VDC

24 VDC

DC Input Voltage Range:

10-15 VDC

20-30 VDC

Nominal Output Volts:

230 VAC ± 5%

230 VAC ± 5%

Nominal Output Frequency:

50 Hz

50 Hz

BATTERY CHARGER

 

 

Charging Capacity DC:

60A

30A

Acceptance Volts VDC:

Selectable

Selectable:

 

14.4V/14.2VWet/Gel

28.8V/28.4VWet/Gel

Float Volts VDC:

13.3V Wet/13.6V Gel

26.6V Wet/27.2V Gel

Input Voltage AC:

230V

230V

Input Current AC:

8.5A

8.5A

LINE VAC OPERATION

 

 

Minimum Input AC Volts:

Selectable:

Selectable:

 

144**, 163, 182, or 201VAC

144**, 163, 182, or 201VAC

Maximum Input AC Volts:

Selectable: 259** or 264 VAC

Selectable: 259** or 264 VAC

Maximum Input Current

 

 

(Continuous, Charger at Maximum):

17.4A

19.1A

Input Frequency:

45-55 Hz

45-55 Hz

Maximum Output AC (Continuous):

8.7A

10.4A

Automatic Transfer Time:

4-6 ms

4-6 ms

 

 

 

HARDWIRED MODELS:

APS 3636 VRI

Weight:

25.6Kg

INVERTER

 

Continuous power (@ 20° C):

3600W

Surge power (5 seconds):

7200W

Efficiency (Full Load):

89%

Minimum DC Fuse Rating:

130A

DC Input Current @ Nominal V DC

 

Full Load :

115A

No Load :

2A*

Nominal DC Input:

36 VDC

DC Input Voltage Range:

30-45 VDC

Nominal Output Volts:

230 VAC ± 5%

Nominal Output Frequency:

50 Hz

BATTERY CHARGER

 

Charging Capacity DC:

30A

Acceptance Volts VDC:

Selectable

 

43.2V/42.6VWet/Gel

Float Volts VDC:

39.9V Wet/40.8V Gel

Input Voltage AC:

230V

Input Current AC:

12.8A

LINE VAC OPERATION

 

Minimum Input AC Volts:

Selectable:

 

144**, 163, 182, or 201VAC

Maximum Input AC Volts:

Selectable: 259** or 264 VAC

Maximum Input Current

 

(Continuous, Charger at Maximum):

30A***

Input Frequency:

45-55 Hz

Maximum Output AC (Continuous):

15.6A

Automatic Transfer Time:

4-6 ms

*Load sense can reduce this to 1/30 of the listed current. **Factory default setting. ***When AVR is boosting incoming current.

15

9906058 230V APS MV-cabinet--English.p65 15

 

 

 

3/21/00, 4:29 PM

Image 15
Contents APS 3636VRI Configuration & Connection pIntroduction Frequency-Controlled Inverter Output Advanced, 3-Stage Battery ChargerVoltage Regulation Select models only Load Sharing Select models onlyEquipment Connection Warnings SafetyBattery Connection Warnings APS Location WarningsSelect High AC Switch To Battery Voltage Point ConfigurationDIP Switch Group a All models Select Battery TypeDIP Switch Group B Available on Select Models Equalize Battery ChargeLoad Sharing Permanent Mounting Optional Battery SelectionSelecting Battery Type Selecting Battery Amp Hour CapacityAC Connection Battery Connection StandardBattery Connection DC Vehicular Use the Shortest and Heaviest Gauge battery cablingAC Input Electrical Connection Hardwired Electrical ConnectionsSet Operating Mode Switch See Diagram 3, pSwitches, Indicator Lights Other Features SwitchesIndicator Lights Other Features Service Maintenance & ServiceLimited Warranty MaintenanceSymptom Problems Corrections TroubleshootingInverter Specifications-Corded ModelsSpecifications-Hardwired Models Configuración y Conexión p Introducción Inversor con Salida de Frecuencia Controlada Cargador Avanzado De 3 Etapas para BateríasRegulación Automática de Voltaje Modelos Selectos Solamente Compartición de Carga Modelos selectos solamentePrecauciones Sobre la Conexión de Equipos SeguridadPrecauciones sobre la Ubicación del APS Precauciones Sobre la Conexión de BateríasSeleccione el Tipo de Baterías ConfiguraciónCompartición de Carga Grupo B DE Interruptores DIP Modelos SelectosPaso Selección de BateríasIgualar la Carga de Baterías Seleccione la Capacidad en Amperios/Hora de las BateríasConexión de Baterías Estándar Escoja la configuración apropiada a sus bateríasVea el Diagrama 2 en la página Instalación Permanente OpcionalConexión de Baterías DC Vehículos Conexión de CAConexiones Eléctricas Directas al Circuito Regule el Interruptor Operating Mode Modo de Operación Conexión de la Entrada Eléctrica de CAConexión de la Salida Eléctrica de CA Luces Indicadoras InterruptoresConector para el Módulo de Control Remoto Todos los modelos Otras CaracterísticasLuz Indicadora Capacidad Terminales de Entrada de CD Todos los modelosServicio en México MantenimientoServicio Garantía Limitada Resolución de Problemas Inversor EspecificacionesModelos CON Toma Directa AL Circuito APS2424 INT APS3636 VRI Diagrams/Esquemas Volts 12V 93-1425 9906057 03/00