Q-Logic 8200 SERIES manual System, To manage external port behavior

Page 45

Q

3 – SANbox SSP Management GUI Reference Navigating the SANbox SSP Management GUI

3.2.1

System

System allows you to manage and configure port settings on the SANbox SSP.

To manage external port behavior:

1.Click System on the left pane window.

2.Navigate within the lower window to the Ports folder.

3.Click the specific port to manage. The Port Information screen displays (see Figure 3-5).

Figure 3-5. System Port Information Screen

The following information displays:

World Wide Port Name

World Wide Node Name

Link State

Link Type

Current Port Settings

Force Fabric

Initiator

Target

Port Speed

Enabled/Disable Port

SN0054628-00 A

3-7

Image 45
Contents SANbox 8200 Series Storage Services Platform Page Table of Contents Section SANbox SSP Management GUI Reference Using the SANbox SSPSection Troubleshooting Figures Tables Page Introduction Audience Readme FileRelated Documentation New in this Release Style Conventions Regulatory and Safety NoticesDeclaration of Conformity ManufacturerProduct Introduction Regulatory and Safety Notices Before Contacting Technical Support Warranty and Technical SupportAvailability TrainingContact Information Introduction Warranty and Technical Support SN0054628-00 a General Description SANbox SSP and StoreAge Solution OverviewSANbox SSP/StoreAge Solution SANbox SSP Overview FeaturesSmall SAN Deployment Configuration with Zoning Supported Network ConfigurationsDual Fabric Configuration Small SAN Configuration with Front/Back-Side SANsHigh-Availability Configuration High-Availability Fabric Configuration Setup Requirements How the Solution Protects Against FailuresPort Connections Fibre Channel Port Connections Ethernet ConnectionsConsole Port Connection General Description Port Connections SN0054628-00 a Task Roadmap Roadmap of Setup TasksChecking Package Contents SANbox 8200/8202 SSP Port Side Setting Up SANbox SSPSANbox 8200/8202 SSP Fan Side Setting Up SANbox SSP HardwareTo mount SANbox SSP in a rack To install the power suppliesTo connect the console port Inserting the Right Power SupplyTo power up SANbox SSP Accessing SANbox SSP for the First TimeTo configure the terminal settings on the host computer To access the CLI through the serial console portGateway Netmask To modify Ethernet settings for remote accessConnecting StoreAge SVM Appliances to the SAN Connecting to the SANTo connect SANbox SSPs to the SAN Connecting SANbox SSPs to the SANConnecting Hosts to the SAN Managing your ConfigurationTo connect hosts to the SAN Page Managing SANbox SSP SANbox SSP Management GUI ReferenceTo install Java WebStart Using the SANbox SSP Management GUIQLogic SANbox Storage Services Platform SSP Screen To log into the SANbox SSP Management GUI SANbox SSP Management GUI Application Installation ScreenUsing the Command Line Interface Locally Using the Command Line Interface RemotelyTo access the CLI using telnet To access the CLI using sshSANbox SSP Management GUI Functions Navigating the SANbox SSP Management GUITo manage external port behavior SystemEnabling and Disabling Ports System Ethernet Panel Ethernet Panel SystemSystem Sensors Panel Sensors Panel SystemTo use the Diagnostics panel DiagnosticsTelnet Screen Initiated from the SANbox SSP Management GUI TelnetLog 10. Diagnostic Screen Log PanelPage Setting up a High-Availability Configuration Using the SANbox SSPComponent SAN Zoning High-Availability Fabric Configuration with Zoning Yellow zone Pink zone Directly Connecting Devices to SANbox SSPConfiguring Storage AccessZoning Maximum Frame Size Configuration Restriction on RAID DevicesTo create storage pools Using the SVM GUI to Manage Virtual StorageGuidelines for Selecting the Storage Device Profile To create virtual volumesClick Fail Back Failing BackShutting Down SANbox SSP To shut down SANbox SSP using the Main Power SwitchTo restart SANbox SSP from the CLI To shut down SANbox SSP from the CLIUsing the SANbox SSP Shutting Down SANbox SSP SN0054628-00 a SANbox SSP System Software Maintaining the SANbox SSPTo select the active boot set from the local console Boot SetsTo access Maintenance Mode from the local console Maintenance ModeTo install a new system software image on SANbox SSP Updating SANbox SSP System SoftwareTo apply a system software patch Interpreting the LED Patterns To install a new Maintenance Mode image on SANbox SSPPost and the LEDs To replace the power suppliesReplacing Hardware Components To replace the fansTo replace a transceiver About the TransceiversPage Before Looking at the Problem Statements TroubleshootingBACK-END Storage not Found LOOP/FABRIC Problem Statements and Troubleshooting ProceduresCannot LOG Into SANbox SSP GUI or CLI Cannot Access SANbox SSP Console PortInitiator not Found by SVM Media Performance CharacteristicsHigh Availability Features Storage ManagementStandards Mechanical Device ManagementEnvironmental ElectricalRegulatory Command Line Interface CLI Overview Command Quick Reference by ObjectTable B-1. Commands by Object Type Command Syntax and Command Completion Help Commands Online HelpExample To telnet to the CLI from a web browser Accessing the CLIFigure B-2. Telnet Console Login Screen Figure B-3. Telnet Console Menu Options Users and GroupsTable B-2. Built-In Users and Groups Create User Command Commands Clear CommandDelete User Command Group group nameDisable Port Command Disable Eth CommandDisable eth ethernet name Disable portDisable User Command Disable snmpv3 CommandEnable Eth Command Syntax disable snmpv3Enable Port Command Enable snmpv3 CommandEnable User Command Exit Command Help CommandKeywords help partial command name Help Commands Modify Date CommandModify Eth Command Capability port capability Modify Port CommandSpeed port speed Type port typeModify Ports Command Maxframesize size in bytesPorts type port type Modify User Command Modify Timezone CommandPassword Speed port speed NEGOTIATE, 1G, 2GReboot Command Quit CommandReset Port Command Reset portRestart snmp Command Set Community CommandShow Chassis Command Show Date Command Show Community CommandShow Debug Command SerialnumFcptstate DumpFcsexch FcslunsShow Eth Command Show Fan Command Show Eths CommandShow eths Show fanShow Group Command Show Fans CommandShow Groups Command Show ID CommandShow Ports Command Keywords show port port numberShow ports Show ps Command Keywords show ps power supply number Show psShow ps Show snmpv3 Command Show pss CommandShow Status Command Show Therm CommandShow Timezone Command Show Therms CommandShow User Command Show Users CommandShow Voltage Command Show Voltages CommandVersion Command Boot Set Active Boot SetDefault Boot Set Active/Active RAIDInvalid Boot Set Inactive Boot SetMaintenance Mode Image FailoverScsi Personality Valid Boot SetSecondary Path Storage PoolVirtual Disk Virtual VolumeIndex LEDs 3-10,6-5 SN0054628-00 a Index-3 SVM GUI SN0054628-00 a Index-5