Q-Logic 8200 SERIES manual Using the SVM GUI to Manage Virtual Storage, To create storage pools

Page 60

4 – Using the SANbox SSP

Using the SVM GUI to Manage Virtual Storage

Q

See Figure 4-4for a visual representation of the StoreAge-specific restriction affects RAID devices.

 

Valid LUN

 

Configuration

Controller A, Port 1

Controller B, Port 2

LUN 1 - Logical Unit 1

LUN 1 - Logical Unit 1

LUN 2 - Logical Unit 2

LUN 2 - Logical Unit 2

LUN 3 - Logical Unit 3

LUN 3 - Logical Unit 4

 

Logical Unit 1

Incompatible with

Logical Unit 2

StoreAge SVM

 

 

Logical Unit 3

 

Logical Unit 4

Figure 4-4. StoreAge Configuration Restriction on Back-Side Storage RAID Devices

4.5

Using the SVM GUI to Manage Virtual Storage

This section provides general instructions for creating storage pools and virtual volumes, creating groups of HBAs, called UDHs (user defined hosts), and assigning a storage device profile to a UDH. For more information, see the StoreAge documentation.

NOTE: This information is provided for your convenience. For additional details about the SVM GUI, see the StoreAge documentation. If there are differences between the StoreAge documentation and this installation and configuration guide, follow the StoreAge documentation.

To create storage pools:

1.Open the SVM GUI, and open Volume Manager in tree view.

2.Click Pool, click Create, and then select the physical disks that you want to include in the pool.

WARNING!! This step removes the data on the physical disks that are added to the pool. Once a physical disk is added to a pool, the SVM GUI controls that disk. The data on disks that are not in a pool are not subject to this issue.

NOTE: When you create the first storage pool, you are prompted to provide a domain name that identifies the management domain for the SVM appliance. Enter a domain name, and then click the Submit button to commit the new name to the configuration.

3.Enter a name for the pool, and then click Continue.

4-8

SN0054628-00 A

Image 60
Contents SANbox 8200 Series Storage Services Platform Page Table of Contents Using the SANbox SSP Section SANbox SSP Management GUI ReferenceSection Troubleshooting Figures Tables Page Introduction Audience Readme FileRelated Documentation Style Conventions Regulatory and Safety Notices New in this ReleaseDeclaration of Conformity ManufacturerProduct Introduction Regulatory and Safety Notices Warranty and Technical Support Before Contacting Technical SupportAvailability TrainingContact Information Introduction Warranty and Technical Support SN0054628-00 a SANbox SSP and StoreAge Solution Overview General DescriptionSANbox SSP/StoreAge Solution Features SANbox SSP OverviewSupported Network Configurations Small SAN Deployment Configuration with ZoningSmall SAN Configuration with Front/Back-Side SANs Dual Fabric ConfigurationHigh-Availability Configuration High-Availability Fabric Configuration How the Solution Protects Against Failures Setup RequirementsPort Connections Fibre Channel Port Connections Ethernet ConnectionsConsole Port Connection General Description Port Connections SN0054628-00 a Roadmap of Setup Tasks Task RoadmapChecking Package Contents Setting Up SANbox SSP SANbox 8200/8202 SSP Port SideSetting Up SANbox SSP Hardware SANbox 8200/8202 SSP Fan SideTo install the power supplies To mount SANbox SSP in a rackInserting the Right Power Supply To connect the console portAccessing SANbox SSP for the First Time To power up SANbox SSPTo configure the terminal settings on the host computer To access the CLI through the serial console portTo modify Ethernet settings for remote access Gateway NetmaskConnecting to the SAN Connecting StoreAge SVM Appliances to the SANConnecting SANbox SSPs to the SAN To connect SANbox SSPs to the SANConnecting Hosts to the SAN Managing your ConfigurationTo connect hosts to the SAN Page SANbox SSP Management GUI Reference Managing SANbox SSPUsing the SANbox SSP Management GUI To install Java WebStartQLogic SANbox Storage Services Platform SSP Screen SANbox SSP Management GUI Application Installation Screen To log into the SANbox SSP Management GUIUsing the Command Line Interface Remotely Using the Command Line Interface LocallyTo access the CLI using telnet To access the CLI using sshNavigating the SANbox SSP Management GUI SANbox SSP Management GUI FunctionsSystem To manage external port behaviorEnabling and Disabling Ports Ethernet Panel System System Ethernet PanelSensors Panel System System Sensors PanelDiagnostics To use the Diagnostics panelTelnet Telnet Screen Initiated from the SANbox SSP Management GUI10. Diagnostic Screen Log Panel LogPage Using the SANbox SSP Setting up a High-Availability ConfigurationComponent SAN Zoning High-Availability Fabric Configuration with Zoning Directly Connecting Devices to SANbox SSP Yellow zone Pink zoneConfiguring Storage AccessZoning Configuration Restriction on RAID Devices Maximum Frame SizeUsing the SVM GUI to Manage Virtual Storage To create storage poolsTo create virtual volumes Guidelines for Selecting the Storage Device ProfileFailing Back Click Fail BackTo shut down SANbox SSP using the Main Power Switch Shutting Down SANbox SSPTo restart SANbox SSP from the CLI To shut down SANbox SSP from the CLIUsing the SANbox SSP Shutting Down SANbox SSP SN0054628-00 a Maintaining the SANbox SSP SANbox SSP System SoftwareBoot Sets To select the active boot set from the local consoleMaintenance Mode To access Maintenance Mode from the local consoleTo install a new system software image on SANbox SSP Updating SANbox SSP System SoftwareTo apply a system software patch To install a new Maintenance Mode image on SANbox SSP Interpreting the LED PatternsTo replace the power supplies Post and the LEDsReplacing Hardware Components To replace the fansAbout the Transceivers To replace a transceiverPage Troubleshooting Before Looking at the Problem StatementsProblem Statements and Troubleshooting Procedures BACK-END Storage not Found LOOP/FABRICCannot Access SANbox SSP Console Port Cannot LOG Into SANbox SSP GUI or CLIInitiator not Found by SVM Performance Characteristics MediaHigh Availability Features Storage ManagementStandards Device Management MechanicalEnvironmental ElectricalRegulatory Command Line Interface CLI Overview Command Quick Reference by ObjectTable B-1. Commands by Object Type Command Syntax and Command Completion Help Commands Online HelpExample Accessing the CLI To telnet to the CLI from a web browserFigure B-2. Telnet Console Login Screen Users and Groups Figure B-3. Telnet Console Menu OptionsTable B-2. Built-In Users and Groups Commands Clear Command Create User CommandDelete User Command Group group nameDisable Eth Command Disable Port CommandDisable eth ethernet name Disable portDisable snmpv3 Command Disable User CommandEnable Eth Command Syntax disable snmpv3Enable Port Command Enable snmpv3 CommandEnable User Command Exit Command Help CommandKeywords help partial command name Help Commands Modify Date CommandModify Eth Command Modify Port Command Capability port capabilitySpeed port speed Type port typeModify Ports Command Maxframesize size in bytesPorts type port type Modify Timezone Command Modify User CommandPassword Speed port speed NEGOTIATE, 1G, 2GQuit Command Reboot CommandReset Port Command Reset portRestart snmp Command Set Community CommandShow Chassis Command Show Community Command Show Date CommandShow Debug Command SerialnumDump FcptstateFcsexch FcslunsShow Eth Command Show Eths Command Show Fan CommandShow eths Show fanShow Fans Command Show Group CommandShow Groups Command Show ID CommandShow Ports Command Keywords show port port numberShow ports Show ps Command Keywords show ps power supply number Show psShow ps Show pss Command Show snmpv3 CommandShow Status Command Show Therm CommandShow Therms Command Show Timezone CommandShow User Command Show Users CommandShow Voltage Command Show Voltages CommandVersion Command Active Boot Set Boot SetDefault Boot Set Active/Active RAIDInactive Boot Set Invalid Boot SetMaintenance Mode Image FailoverValid Boot Set Scsi PersonalitySecondary Path Storage PoolVirtual Volume Virtual DiskIndex LEDs 3-10,6-5 SN0054628-00 a Index-3 SVM GUI SN0054628-00 a Index-5