Pelco FR82011 manual 10BASE-T/100BASE-TX Modes of Operation, Flow control default setting

Page 13

Using the TX Mode switch, you can do the following:

Enable autonegotiation or select (force) a specific data rate and duplex mode:

Enabling autonegotiation allows the FT82011/FR82011 module to automatically negotiate with the device to which the port is connected for data rate and duplex modes of operation: 10 Mbps or 100 Mbps data rate and half-duplex or full-duplex mode.

The highest common denominator of operational modes is automatically selected. Autonegotiation is enabled by default.

If autonegotiation is not desired, you can select a specific data rate and duplex mode:

Data rate configuration allows you to select 10 Mbps or 100 Mbps.

Duplex mode configuration allows you to select half-duplex mode or full-duplex mode.

Enable or disable flow control. Flow control controls data transmission at the sending device to avoid overfilling buffers and losing data at the receiving device. When the buffers on the receiving device are full, a message is sent to the sending device to suspend the transmission until the data in the buffers has been processed.

NOTE: For time-sensitive data applications (for example, video and audio applications), it is recommended that flow control be disabled.

Flow control is disabled by default.

With the FT82011/FR82011 module powered off, set each TX Mode switch to the desired 10BASE-T/ 100BASE-TX port modes of operation. Refer to Table A for TX Mode switch settings and corresponding modes of operation. Note that each 10BASE-T/100BASE-TX port operates independently of one another; therefore, each port can be set to different modes of operation as appropriate.

 

 

 

Table A. TX Mode Switch Settings

 

 

 

 

TX Mode

 

 

 

Switch Position

 

 

10BASE-T/100BASE-TX Modes of Operation

 

 

 

Auto Neg/Dis FC—Enables autonegotiation between 10 Mbps and

0

100

Mbps and between half-duplex and full-duplex modes, disables

 

flow control (default setting)

 

 

 

1

100

FD/Dis FC—Selects 100 Mbps full-duplex, disables flow control

 

 

 

2

100

HD/DIS FC—Selects 100 Mbps half-duplex, disables flow control

 

 

 

3

10

FD/Dis FC—Selects 10 Mbps full-duplex, disables flow control

 

 

 

4

10

HD/Dis FC—Selects 10 Mbps half-duplex, disables flow control

 

 

5

Auto Neg/En FC—Enables autonegotiation between 10 and 100 Mbps

and between half-duplex and full-duplex modes, enables flow control

 

 

 

 

6

100

FD/En FC—Selects 100 Mbps full-duplex, enables flow control

 

 

 

7

100

HD/En FC—Selects 100 Mbps half-duplex, enables flow control

 

 

 

8

10

FD/En FC—Selects 10 Mbps full-duplex, enables flow control

 

 

 

9

10

HD/En FC—Selects 10 Mbps half-duplex, enables flow control

 

 

 

 

NOTE: Switch positions 0-4 disable flow control. Positions 5-9 enable flow control.

NOTE: TX Mode configuration must be set when the module is powered off. If you wish to change a TX Mode switch setting after the module has been powered on, power off the module, change the TX Mode switch setting, and then power on the module again.

C2653M (6/07)

13

Image 13
Contents FT82011/FR82011 Ethernet Media Converter Page List of Illustrations ContentsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewC2653M 6/07 Multimode Models ModelsSingle-Mode Models*† RK5000PS-5U rack mount chassisFront Panel Rear Panel 10BASE-T/100BASE-TX Ports 1-4, RJ-45 connectorsPackage Contents Installation10BASE-T/100BASE-TX Modes of Operation Flow control default settingMounting the FT82011/FR82011 Module Into a Rack MountingMounting the FT82011/FR82011 Module Using the Wall Clip Connections Fiber connection Troubleshooting Color Meaning Optic Fault LEDReceive optical signal Any of the following fault conditions If the cable isCheck for problems Budget specification statedLaser has reached end of life Meaning Possible Cause Corrective Action Optic Fault LEDLished Is not desired, refer to the Setting Table C. Troubleshooting with Rear-Panel IndicatorsAmber Amber Is occurringNot lit Meaning Possible CauseFull-duplex Desired, no action is required. IfMode Occur on a half-duplex link Required Half-duplexColor Meaning Possible Cause Corrective Action Mode Not desired, refer to the SettingDesired, no action is required Or if it is not the proper cableNot lit Quality of Service SpecificationsWeighted fair queuing scheduling Receiver Model Number Wavelength Optical Maximum Transmit/ReceiveEnd Multimode 62.5/125 μmNot used Appendix. RJ-45 Connector PinoutsC2653M 6/07 Product Warranty and Return Information ISO9001