Pelco FR82011 manual Not lit

Page 26

Table C. Troubleshooting with Rear-Panel Indicators (Continued)

Indicator

Color

Meaning

Possible Cause

Corrective Action

RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Collision) (Continued)

Not lit

Port is set to 10BASE-T half-duplex mode and no collisions are detected.*

If 10BASE-T half-duplex operation is desired, no action is required.

If 10BASE-T half-duplex operation is not desired, refer to the Setting 10BASE-T/100BASE-TX Port Modes of Operation section in this manual for information.

*A collision is a normal event on a half-duplex Ethernet link. A collision occurs when two or more devices, referred to as stations, attempt to transmit at the same time on a shared physical medium.

Ethernet uses the CSMA/CD (Carrier Sense Multiple Access/Collision Detect) media access method by which two or more stations share a common transmission medium. Using CSMA/CD, a station monitors the medium and transmits a message in bit-serial form when it senses that no other station is transmitting. If, after initiating a transmission, the message collides with that of another station, each transmitting station then intentionally transmits for an additional predefined period to ensure propagation of the collision throughout the system. To avoid another collision, each station waits a random amount of time (backoff) before attempting to transmit again.

Excessive collisions occur when retransmission of a frame fails after 16 consecutive times and the frame is dropped. Excessive collisions may indicate that the network is becoming congested.

26

C2653M (6/07)

Image 26
Contents FT82011/FR82011 Ethernet Media Converter Page List of Tables ContentsList of Illustrations Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionC2653M 6/07 Single-Mode Models*† ModelsMultimode Models RK5000PS-5U rack mount chassisFront Panel 10BASE-T/100BASE-TX Ports 1-4, RJ-45 connectors Rear PanelInstallation Package ContentsFlow control default setting 10BASE-T/100BASE-TX Modes of OperationMounting Mounting the FT82011/FR82011 Module Into a RackMounting the FT82011/FR82011 Module Using the Wall Clip Connections Fiber connection Troubleshooting Optic Fault LED Color MeaningCheck for problems Any of the following fault conditions If the cable isReceive optical signal Budget specification statedMeaning Possible Cause Corrective Action Optic Fault LED Laser has reached end of lifeAmber Table C. Troubleshooting with Rear-Panel IndicatorsLished Is not desired, refer to the Setting Amber Is occurringMeaning Possible Cause Not litMode Desired, no action is required. IfFull-duplex Occur on a half-duplex link Required Half-duplexDesired, no action is required Mode Not desired, refer to the SettingColor Meaning Possible Cause Corrective Action Or if it is not the proper cableNot lit Weighted fair queuing scheduling SpecificationsQuality of Service End Model Number Wavelength Optical Maximum Transmit/ReceiveReceiver Multimode 62.5/125 μmAppendix. RJ-45 Connector Pinouts Not usedC2653M 6/07 Product Warranty and Return Information ISO9001