Specifications

PERFORMANCE

 

Switch Type

Unmanaged Layer 2

Switch Method

Store and forward

Data Rate

10/100 Mbps

Compliance

IEEE 802.3, 802.3u, 802.3x

Interface

Auto MDI/MDI-X

Operating Mode

Full-duplex or half-duplex

Address Table Size

1,024 MAC address entries with automatic learning and aging

Quality of Service

IEEE 802.1p priority, tag-based, four queues per port,

 

weighted fair queuing scheduling

Maximum Frame Size

Untagged Ethernet frames up to 1,518 bytes

 

Tagged Ethernet frames up to 1,522 bytes

GENERAL

 

Operating Temperature

-40° to 167°F (-40° to 75°C)

Input Power Requirements

12 VDC or 24 VAC, 0.50 A

LED Indicators

Power

 

100BASE-FX port status (link/activity, FEFI)

 

Optic Fault (optic signal/laser status)

 

10BASE-T/100BASE-TX port status (two LEDs:

 

link/activity and speed, duplex/collision and speed)

Dimensions

8.75" D x 1.08" W x 4.81" H

 

(22.23 x 2.74 x 12.22 cm)

Unit Weight

1.6 lb (0.73 kg)

MECHANICAL

 

Connectors

 

Rack Power/Alarm

One 4-pin connector

Stand-Alone Power

One 2-pin connector, screw terminal

Electrical

One RJ-45, 10BASE-T/100BASE-TX

Fiber Optic

One single-fiber ST or SC

C2653M (6/07)

27

Image 27
Contents FT82011/FR82011 Ethernet Media Converter Page Contents List of IllustrationsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewC2653M 6/07 RK5000PS-5U rack mount chassis ModelsMultimode Models Single-Mode Models*†Front Panel Rear Panel 10BASE-T/100BASE-TX Ports 1-4, RJ-45 connectorsPackage Contents Installation10BASE-T/100BASE-TX Modes of Operation Flow control default settingMounting the FT82011/FR82011 Module Into a Rack MountingMounting the FT82011/FR82011 Module Using the Wall Clip Connections Fiber connection Troubleshooting Color Meaning Optic Fault LEDBudget specification stated Any of the following fault conditions If the cable isReceive optical signal Check for problemsLaser has reached end of life Meaning Possible Cause Corrective Action Optic Fault LEDAmber Is occurring Table C. Troubleshooting with Rear-Panel IndicatorsLished Is not desired, refer to the Setting AmberNot lit Meaning Possible CauseOccur on a half-duplex link Required Half-duplex Desired, no action is required. IfFull-duplex ModeOr if it is not the proper cable Mode Not desired, refer to the SettingColor Meaning Possible Cause Corrective Action Desired, no action is requiredNot lit Specifications Quality of ServiceWeighted fair queuing scheduling Multimode 62.5/125 μm Model Number Wavelength Optical Maximum Transmit/ReceiveReceiver EndNot used Appendix. RJ-45 Connector PinoutsC2653M 6/07 Product Warranty and Return Information ISO9001