Pelco manual Mounting the FT82011/FR82011 Module Into a Rack

Page 14

MOUNTING

The FT82011/FR82011 module can be mounted into a rack or can be used as a stand-alone module. As a stand-alone module, the unit can be placed on a desktop or can be mounted to a wall.

NOTE: As a matter of convenience, it is recommended that you set the modes of operation for the 10BASE-T/100-BASE-TX port—if required—before mounting the FT82011/FR82011 module into a rack or onto a wall. For information about setting the port modes of operation, refer to the Setting 10BASE-T/100BASE-TX Port Modes of Operation section.

MOUNTING THE FT82011/FR82011 MODULE INTO A RACK

The FT82011/FR82011 module can be installed into an RK5000 Series rack mount chassis, which can be mounted into an industry-standard 19-inch (48.26 cm) equipment rack. The RK5000 Series rack mount chassis includes the following models:

RK5000PS-3U and RK5000-3U:Designed to accommodate fiber optic modules as follows:

The RK5000PS-3U rack mount chassis provides 12 single-width module slots and a power supply.

The RK5000-3U rack mount chassis provides 14 single-width module slots (a power supply is not included). Power to the modules can be supplied using the optional external power supply (EPS5000-120).

For additional information, refer to the RK5000PS-3U/RK5000-3U Fiber Rack Mount Chassis Installation manual.

RK5000PS-5U:Designed to accommodate Enduramodules but can also accommodate fiber optic modules with the use of the appropriate adapter kit. The RK5001-1UEXP adapter kit is required for installation of the FT82011/FR82011 module into the RK5000PS-5U chassis.

For information about the RK5000PS-5U chassis, refer to the RK5000PS-5U Rack Mount Chassis Installation manual.

MOUNTING THE FT82011/FR82011 MODULE TO A WALL

The FT82011/FR82011 module can be mounted to a wall in the following ways:

Using the supplied wall clip for attachment of a single module to a wall. For installation instructions, refer to the Mounting the FT82011/FR82011 Module Using the Wall Clip section.

Using the optional WM5001 wall mount kits, which are designed for mounting of single-width fiber optic modules. The WM5001-3U base kit allows mounting of a single module to a wall. The WM5001-3UEXP expansion kit allows mounting of an additional module. It is recommended that a maximum of three expansion kits be used with the base kit, allowing a maximum of four single-width modules to be mounted to a wall.

NOTE: The WM5001 wall mount kits can be used with the WM5002 wall mount kits, which are designed for mounting of double-width fiber optic modules. If mounting a mix of single-width and double-width modules is desired, it is recommended that a maximum of two single-width modules and one double-width module be mounted in combination with one another.

For mounting instructions using the wall mount kits, refer to the WM5000 Series Wall Mount Kit Installation manual.

14

C2653M (6/07)

Image 14
Contents FT82011/FR82011 Ethernet Media Converter Page List of Tables ContentsList of Illustrations Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionC2653M 6/07 Single-Mode Models*† ModelsMultimode Models RK5000PS-5U rack mount chassisFront Panel 10BASE-T/100BASE-TX Ports 1-4, RJ-45 connectors Rear PanelInstallation Package ContentsFlow control default setting 10BASE-T/100BASE-TX Modes of OperationMounting Mounting the FT82011/FR82011 Module Into a RackMounting the FT82011/FR82011 Module Using the Wall Clip Connections Fiber connection Troubleshooting Optic Fault LED Color MeaningCheck for problems Any of the following fault conditions If the cable isReceive optical signal Budget specification statedMeaning Possible Cause Corrective Action Optic Fault LED Laser has reached end of lifeAmber Table C. Troubleshooting with Rear-Panel IndicatorsLished Is not desired, refer to the Setting Amber Is occurringMeaning Possible Cause Not litMode Desired, no action is required. IfFull-duplex Occur on a half-duplex link Required Half-duplexDesired, no action is required Mode Not desired, refer to the SettingColor Meaning Possible Cause Corrective Action Or if it is not the proper cableNot lit Weighted fair queuing scheduling SpecificationsQuality of Service End Model Number Wavelength Optical Maximum Transmit/ReceiveReceiver Multimode 62.5/125 μmAppendix. RJ-45 Connector Pinouts Not usedC2653M 6/07 Product Warranty and Return Information ISO9001