Pelco FR82011 manual Meaning Possible Cause Corrective Action Optic Fault LED

Page 21

Table B. Troubleshooting with Front-Panel Indicators (Continued)

Indicator

 

 

 

 

Color

Meaning

Possible Cause

Corrective Action

 

 

 

 

 

 

 

Optic Fault LED (

) (Continued)

 

Flashing red

Ethernet link is down.

NOTE: In addition to a flashing red Optic Fault LED, the 100BASE-FX LED is red and the left RJ-45 Port Status LED (Link/Activity) LED is not lit.

Laser has shut down due to either of the following fault conditions:

Module is operating in extreme environmental conditions; for example, operating temperature is below or above recommended range as stated in the Specifications section.

Laser has reached end of life.

Ensure that module oper- ates according to operat- ing conditions stated in the Specifications section, and then cycle the power.

If problem persists, contact Product Support.

C2653M (6/07)

21

Image 21
Contents FT82011/FR82011 Ethernet Media Converter Page Contents List of IllustrationsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Radio and Television Interference Regulatory NoticesDescription Product OverviewC2653M 6/07 Multimode Models ModelsSingle-Mode Models*† RK5000PS-5U rack mount chassisFront Panel Rear Panel 10BASE-T/100BASE-TX Ports 1-4, RJ-45 connectorsPackage Contents Installation10BASE-T/100BASE-TX Modes of Operation Flow control default settingMounting the FT82011/FR82011 Module Into a Rack MountingMounting the FT82011/FR82011 Module Using the Wall Clip Connections Fiber connection Troubleshooting Color Meaning Optic Fault LEDReceive optical signal Any of the following fault conditions If the cable isCheck for problems Budget specification statedLaser has reached end of life Meaning Possible Cause Corrective Action Optic Fault LEDLished Is not desired, refer to the Setting Table C. Troubleshooting with Rear-Panel IndicatorsAmber Amber Is occurringNot lit Meaning Possible CauseFull-duplex Desired, no action is required. IfMode Occur on a half-duplex link Required Half-duplexColor Meaning Possible Cause Corrective Action Mode Not desired, refer to the SettingDesired, no action is required Or if it is not the proper cableNot lit Specifications Quality of ServiceWeighted fair queuing scheduling Receiver Model Number Wavelength Optical Maximum Transmit/ReceiveEnd Multimode 62.5/125 μmNot used Appendix. RJ-45 Connector PinoutsC2653M 6/07 Product Warranty and Return Information ISO9001