Pelco FR82011 manual Model Number Wavelength Optical Maximum Transmit/Receive, Receiver, End

Page 28

OPTICAL POWER BUDGET AND MAXIMUM TRANSMISSION DISTANCE

Model Number

 

Wavelength

Optical

Maximum

 

 

 

(Transmit/Receive)*

Transmitter

Receiver

 

Power

Transmission

 

 

 

End

End

 

Fiber Port A

Fiber Port B

Budget

Distance

 

 

 

 

 

 

 

Multimode (62.5/125 μm)

 

 

 

 

 

 

 

 

FT82011MSTR-1

FR82011MSTR-1

 

1310/850 nm

850/1310 nm

26 dB

2 km (1.2 mi)

FT82011MSCR-1

FR82011MSCR-1

 

1310/850 nm

850/1310 nm

26 dB

2 km (1.2 mi)

 

 

Single-Mode (9/125 μm)

 

 

 

 

 

 

 

 

FT82011SSTR-1

FR82011SSTR-1

 

1310/1550 nm

1550/1310 nm

28 dB

46 km (28.6 mi)§

FT82011SSCR-1

FR82011SSCR-1

 

1310/1550 nm

1550/1310 nm

28 dB

46 km (28.6 mi)§

* The FT82011 and FR82011 modules are classified by the FDA as Class 1 laser products. For 850 nm, the Class 1 laser limit is <0.78 mW. For 1310 nm, the Class 1 laser limit is <15.6 mW. For 1550 nm, the Class 1 laser limit is <10.0 mW.

When using 50/125 μm multimode fiber, subtract 3 dB from the optical power budget.

Maximum transmission distance is limited by fiber bandwidth.

§ Maximum transmission distance is based on attenuation of 0.5 dB/km plus a 5 dB buffer for connector and splice losses.

NOTES:

Single-mode FC connector is available upon request. Contact the factory for additional information.

For conformal coated models, replace the first letter F in the model number with the letter C. The conformal coated version of FT82011MSTR-1, for example, is CT82011MSTR-1.

For models with higher optical power budgets, contact the factory.

28

C2653M (6/07)

Image 28
Contents FT82011/FR82011 Ethernet Media Converter Page List of Illustrations ContentsList of Tables Important Safety Instructions Risk of Electric Shock Do not Open Regulatory Notices Radio and Television InterferenceProduct Overview DescriptionC2653M 6/07 Models Multimode ModelsSingle-Mode Models*† RK5000PS-5U rack mount chassisFront Panel 10BASE-T/100BASE-TX Ports 1-4, RJ-45 connectors Rear PanelInstallation Package ContentsFlow control default setting 10BASE-T/100BASE-TX Modes of OperationMounting Mounting the FT82011/FR82011 Module Into a RackMounting the FT82011/FR82011 Module Using the Wall Clip Connections Fiber connection Troubleshooting Optic Fault LED Color MeaningAny of the following fault conditions If the cable is Receive optical signalCheck for problems Budget specification statedMeaning Possible Cause Corrective Action Optic Fault LED Laser has reached end of lifeTable C. Troubleshooting with Rear-Panel Indicators Lished Is not desired, refer to the SettingAmber Amber Is occurringMeaning Possible Cause Not litDesired, no action is required. If Full-duplexMode Occur on a half-duplex link Required Half-duplexMode Not desired, refer to the Setting Color Meaning Possible Cause Corrective ActionDesired, no action is required Or if it is not the proper cableNot lit Quality of Service SpecificationsWeighted fair queuing scheduling Model Number Wavelength Optical Maximum Transmit/Receive ReceiverEnd Multimode 62.5/125 μmAppendix. RJ-45 Connector Pinouts Not usedC2653M 6/07 Product Warranty and Return Information ISO9001