TABLE 1-2 Hot-Swap BLUE LED States
Order | Visible State | State | Description |
|
|
|
|
1 | Solid | M1 FRU Inactive | The Intelligent Platform |
|
|
| Management Interface (IPMI) |
|
|
| microcontroller is booted, but the |
|
|
| payload is not. The bottom latch is |
|
|
| not fully closed or the activation |
|
|
| lock bit set is keeping AMC from |
|
|
| activating. |
2 | Blinking (from solid) | M2 Activation | The bottom latch is closed or |
|
| Request | activation lock bit has been cleared. |
|
|
| The IPMI microcontroller has |
|
|
| requested permission to boot the |
|
|
| payload from the shelf |
|
|
| management controller. |
3 | Off | The IPMI microcontroller has | |
|
|
| received permission to activate the |
|
|
| payload, and has done so. This |
|
|
| should be the state under normal |
|
|
| operation. |
4 | Blinking (from off) | The IPMI microcontroller has | |
|
| Deactivation | requested permission to deactivate. |
|
| Request | Opening the bottom latch or |
|
|
| resetting the deactivation lock bit |
|
|
| activates this state. |
|
|
|
|
Note – An AMC should be
Chapter 1 Getting Started |