Sun Microsystems CP3000 manual Appendix a Connectors and Ports

Page 55

TABLE A-1Pin Assignments (Continued)

9

12V

54

'PCIe_RX1_N'

99

No Connect

144

No Connect

10

GND

55

GND

100

No Connect

145

No Connect

11

No Connect

56

'IPMI_SCL_L'

101

GND

146

GND

12

No Connect

57

12V

102

No Connect

147

No Connect

13

GND

58

GND

103

No Connect

148

No Connect

14

No Connect

59

'PCIe_TX2_P'

104

GND

149

GND

15

No Connect

60

'PCIe_TX2_N'

105

No Connect

150

No Connect

16

GND

61

GND

106

No Connect

151

No Connect

17

GA1

62

'PCIe_RX2_P'

107

GND

152

GND

18

12V

63

'PCIe_RX2_N'

108

No Connect

153

No Connect

19

GND

64

GND

109

No Connect

154

No Connect

20

'PORT1_PTX0_P'

65

'PCIe_TX3_P'

110

GND

155

GND

21

'PORT1_PTX0_N'

66

'PCIe_TX3_N'

111

No Connect

156

No Connect

22

GND

67

GND

112

No Connect

157

No Connect

23

'PORT1_PRX0_P'

68

'PCIe_RX3_P'

113

GND

158

GND

24

'PORT1_PRX0_N'

69

'PCIe_RX3_N'

114

No Connect

159

No Connect

25

GND

70

GND

115

No Connect

160

No Connect

26

GA2

71

'IPMI_SDA_L'

116

GND

161

GND

27

12V

72

12V

117

No Connect

162

No Connect

28

GND

73

GND

118

No Connect

163

No Connect

29

'TX_SAS_2+'

74

No Connect

119

GND

164

GND

30

'TX_SAS_2-'

75

No Connect

120

No Connect

165

No Connect

31

GND

76

GND

121

No Connect

166

No Connect

32

'RX_SAS_2+'

77

No Connect

122

GND

167

No Connect

33

'RX_SAS_2-'

78

No Connect

123

No Connect

168

No Connect

34

GND

79

GND

124

No Connect

169

No Connect

35

'TX_SAS_3+'

80

PREFCLKP

125

GND

170

GND

36

'TX_SAS_3-'

81

PREFCLKN

126

No Connect

 

 

37

GND

82

GND

127

No Connect

 

 

38

'RX_SAS_3+'

83

'PRSNT0_L'

128

GND

 

 

39

'RX_SAS_3-'

84

12V

129

No Connect

 

 

 

 

 

 

 

 

 

 

Appendix A Connectors and Ports

A-3

Image 55
Contents For the AMC.1-HDD SAS Disk Please Recycle Contents Managing the AMC OverviewAgency Certifications Configuring the AMCConnectors and Ports Environment SpecificationsIndex Index-1 Typographic Conventions PrefaceThird-Party Web Sites Related DocumentationSun Welcomes Your Comments Page Getting Started Important Safety Information for Sun Hardware SystemsBlade Server Compatibility System RequirementsOperating Systems Compatibility Chassis CompatibilityElectrical and Environmental UnpackingHandling AMCs 1AMC.1-HDD SAS Disk Faceplate AMC Faceplate1AMC Status LEDs AMC LEDs2Hot-Swap Blue LED States Removing an AMC Removing and Installing AMCsShut down the payload OS Hot-Swap LED starts blinking 2Deactivating the AMC 3Removing the AMC Remove the AMC4Front Cable Management Bracket in Lower Position Removing a Blade Server and AMCRemove the filler panel, if necessary Installing an AMC5Sample Top View Obtain the AMC card from the ship kit6Opening the Injector/Ejector Latch Page 7Inserting the AMC Into a Blade Server Push the ejector latch in fullyEnabling and Disabling SAS Ports To Enable AMC Port 2 Driven by Port 1 of SAS ControllerTo Enable AMC Port 3 Driven by Port 2 of SAS Controller Power on the system, if necessaryTo Disable AMC Port 3 Driven by Port 2 of SAS Controller To Disable AMC Port 2 Driven by Port 1 of SAS ControllerPage Overview Features Key Components Power RegulatorHard Drive Disk Flash SAS ControllerModule Management Controller MMC Faceplate and LEDs Port ConnectorsLEDs OOS Technical Support and Warranty Functional DiagramPage 4Sun Netra CP3000 AMC.1-HDD SAS disk Barcode Labeling Disposal Managing the AMC Monitoring and Control Functions Supported Ipmi CommandsIpmi Controller 1Supported Ipmi Commands 2Standard FRU Data Records FRU Information3Threshold Sensors SensorsReadme files within the download package Firmware and Software UpgradesConfiguring the AMC Boot Bios Utility Configuration ToolsLaunching the Boot Bios Utility Features and ConfigurationsPress Ctrl C Page 2Adapter Properties Menu OpenBoot BiosEnabling and Disabling Channel Ports Extensible Firmware Interface EFIConnectors and Ports Connector Pinouts Connector Locations and AssignmentsTable A-1Pin Assignments Appendix a Connectors and Ports SAS Controller Ports 1AMC e-Keying Port Assignments Keying PortsPage Environment Specifications Electrical Table B-1Electrical SpecificationsTable B-2Environmental Specifications Electrical and EnvironmentalRPM Table B-3MTBF Values by TemperatureAbsolute Maximum Ratings ReliabilityNormal Operating Ranges AMC.1-HDD SAS disk PCB Dimensions Board Dimensions and WeightMechanical Page Agency Certifications NEBS/ETSI CE CertificationSafety 1 EN 55022 Emissions Emissions Test Regulations2 EN 55024 Immunity FCC USA Regulatory InformationIndustry Canada Canada Page Numerics IndexNEBS/ETSI, C-2