Sun Microsystems CP3000 manual SAS Controller Ports

Page 56

TABLE A-1Pin Assignments (Continued)

40

GND

85

GND

130

No Connect

41

'AMC_ENABLE_L'

86

GND

131

GND

42

12V

87

No Connect

132

No Connect

43

GND

88

No Connect

133

No Connect

44

'PCIe_TX0_P'

89

GND

134

GND

45

'PCIe_TX0_N'

90

No Connect

135

No Connect

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A.3 SAS Controller Ports

The AMC.1-HDD SAS disk incorporates four dedicated SAS controller ports as follows.

TABLE A-2

 

SAS Controller Port

Dedicated Function

0

Routes to the onboard SAS disk drive, primary port A

1 (See Note)

Routes to AMC channel 2 (connects to SAS or SATA disk)

2(See Note)

Routes to AMC channel 3 (connects to SAS or SATA disk)

3

No Connect

 

 

These SAS ports are shipped with PHY’s disabled and are not driving AMC ports 2 and 3. This default configura- tion avoids incompatibilities with systems that have other initiators driving these AMC ports.

A-4Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010

Image 56
Contents For the AMC.1-HDD SAS Disk Please Recycle Contents Overview Managing the AMCConfiguring the AMC Connectors and PortsEnvironment Specifications Agency CertificationsIndex Index-1 Preface Typographic ConventionsRelated Documentation Third-Party Web SitesSun Welcomes Your Comments Page Important Safety Information for Sun Hardware Systems Getting StartedSystem Requirements Operating Systems CompatibilityChassis Compatibility Blade Server CompatibilityUnpacking Electrical and EnvironmentalHandling AMCs AMC Faceplate 1AMC.1-HDD SAS Disk FaceplateAMC LEDs 1AMC Status LEDs2Hot-Swap Blue LED States Shut down the payload OS Removing and Installing AMCsRemoving an AMC Hot-Swap LED starts blinking 2Deactivating the AMC Remove the AMC 3Removing the AMCRemoving a Blade Server and AMC 4Front Cable Management Bracket in Lower PositionInstalling an AMC Remove the filler panel, if necessaryObtain the AMC card from the ship kit 5Sample Top View6Opening the Injector/Ejector Latch Page Push the ejector latch in fully 7Inserting the AMC Into a Blade ServerTo Enable AMC Port 2 Driven by Port 1 of SAS Controller To Enable AMC Port 3 Driven by Port 2 of SAS ControllerPower on the system, if necessary Enabling and Disabling SAS PortsTo Disable AMC Port 2 Driven by Port 1 of SAS Controller To Disable AMC Port 3 Driven by Port 2 of SAS ControllerPage Overview Features Hard Drive Disk Power RegulatorKey Components Module Management Controller MMC SAS ControllerFlash LEDs Port ConnectorsFaceplate and LEDs OOS Functional Diagram Technical Support and WarrantyPage 4Sun Netra CP3000 AMC.1-HDD SAS disk Barcode Labeling Disposal Managing the AMC Ipmi Controller Supported Ipmi CommandsMonitoring and Control Functions 1Supported Ipmi Commands FRU Information 2Standard FRU Data RecordsSensors 3Threshold SensorsFirmware and Software Upgrades Readme files within the download packageConfiguring the AMC Configuration Tools Boot Bios UtilityPress Ctrl C Features and ConfigurationsLaunching the Boot Bios Utility Page OpenBoot Bios 2Adapter Properties MenuExtensible Firmware Interface EFI Enabling and Disabling Channel PortsConnectors and Ports Table A-1Pin Assignments Connector Locations and AssignmentsConnector Pinouts Appendix a Connectors and Ports SAS Controller Ports Keying Ports 1AMC e-Keying Port AssignmentsPage Environment Specifications Table B-1Electrical Specifications Table B-2Environmental SpecificationsElectrical and Environmental ElectricalTable B-3MTBF Values by Temperature RPMNormal Operating Ranges ReliabilityAbsolute Maximum Ratings Mechanical Board Dimensions and WeightAMC.1-HDD SAS disk PCB Dimensions Page Agency Certifications CE Certification NEBS/ETSISafety 2 EN 55024 Immunity Emissions Test Regulations1 EN 55022 Emissions Industry Canada Canada Regulatory InformationFCC USA Page Index NumericsNEBS/ETSI, C-2