Paradyne 8784 manual Monitoring the Unit

Page 40

4. Monitoring the Unit

Table 4-1. Health and Status Messages (2 of 2)

Message

What Message Indicates

What To Do

 

 

 

 

Net Com Link Down

The Network communication

1.

Verify that the network cable

 

link is down.

 

is securely attached at both

 

Communications between

 

ends.

 

the management system and

2.

Verify the link protocol for the

 

the LTU/NTU is not possible.

 

 

COM port is configured

 

 

 

 

 

 

correctly.

 

 

 

 

Net Margin Threshold,

The signal-to-noise margin

1.

Check the Network

Pt n

has exceeded the configured

 

Performance Statistics

 

threshold.

 

screen for possible line

 

 

 

impairments.

 

 

2.

Set the unit to run at a lower

 

 

 

DSL line rate.

 

 

3.

Contact network provider.

 

 

 

NTU/LTU Mis match,

The NTU is not configured

Configure units to match.

Pt n

compatibly with the LTU.

 

 

 

 

 

 

OOF at Net, Pt n

Three consecutive frame

1.

Check the Transmit Clock

 

synchronization bits were in

 

Source configuration options.

 

error.

 

Do not set both the local and

 

 

 

remote unit to Internal,

 

 

 

External, or Loop timing.

 

 

2.

Set the unit to run at a lower

 

 

 

DSL line rate.

 

 

3.

Contact network provider.

 

 

 

 

Prim Clk Failed Pt n

A failure has occurred in the

1.

Verify that the network cable

 

primary clock source

 

is securely attached at both

 

configured from the Network,

 

ends.

 

DSX, or from the card

2.

Contact network provider.

 

internal clock.

 

 

 

 

 

 

System Operational

There are no problems

No action is needed.

 

detected.

 

 

 

 

 

 

Yellow at DSX-1, Pt n

A Yellow Alarm Indication

1.

Verify that the unit’s line

 

signal is being received by

 

framing and line coding are

 

the DSX-1 interface.

 

compatible.

 

 

2.

Contact network provider.

 

 

 

 

4-4

February 2001

8784-A2-GB20-30

Image 40
Contents Hotwire 8784 TDM Sdsl Termination Unit Copyright 2001 Paradyne Corporation All rights reserved Important Safety Instructions United States EMI Notice Contents Monitoring the Unit Initial Startup and ConfigurationFebruary Testing Messages and TroubleshootingSecurity IP Addressing TConfiguration Options Connector Pin AssignmentsTechnical Specifications Glossary Index Standards ComplianceT for Snmp TrapsDocument Purpose and Intended Audience About This GuideDocument Summary Product-Related Documents Document Number Document TitleAbout the Hotwire Termination Unit TDM Sdsl OverviewHotwire 8784 Termination Unit Features Customer Premises CP Network ConfigurationCO Site Snmp Management Capabilities Management Information Base MIB SupportSnmp Trap Support NetworkUser Interface Access Using the Asynchronous Terminal InterfaceManagement Serial Port Settings Login Logging In to the Hotwire DslamInitiating an ATI Session Select Main MenuMenu Hierarchy SnmpMain Menu→ Configuration → Current Configuration → Network Screen Work AreasFunction KeysKeyboard Keys Navigating the ScreensPress Function Keys For the screen Function Select Press Enter toSwitching Between Screen Work Areas ExampleEnding an ATI Session Exiting From the Dslam SessionUsing the Asynchronous Terminal Interface February Initial Startup and Configuration OverviewMain Menu→ Control→ Change Identity Entering Identity InformationIdentity Main Menu→ Configuration Load Configuration From Configuring the UnitLoad Configuration from Configuration EDIT/DISPLAY Current and Default Factory ConfigurationsIf you select Then Configuration Loader Select To Access To ConfigureMain Menu→ Configuration → Configuration Loader Configuration LoaderCompleted successfully Saving Configuration Changes Save ConfigurationDownloading Firmware Main Menu→ Control → Download CodeDownload Code DSL1Apply Download Main Menu→ Configuration→ Current Configuration → Network AutoRate FeatureDisabling AutoRate Restoring Access to the User Interface Resetting AutoRateMain Menu→ Control→ Reset AutoRate Select Configuration→ DSL Cards → Reset SlotResetting the Unit Main Menu→ Control→ Reset DeviceMonitoring the Unit What to MonitorMain Menu→ Status→ System and Test Status Viewing System and Test StatusSystem and Test Status Health and Status SELF-TEST Results Health and Status Messages YyyyyyyyMonitoring the Unit Test Status Messages Self-Test Results MessagesTest Status Messages Meaning Network Error Statistics Viewing Network Error StatisticsPerformance Statistics SES Severely Errored Seconds Seconds during which more than Field ContainsViewing Network Performance Statistics This Field Contains Viewing Current Network Performance Current Network Performance StatisticsSES FebeMain Menu→ Status→ Performance Statistics→ DSX-1 Statistics Viewing DSX-1 Performance StatisticsDSX-1 Performance Statistics This Field Contains Viewing LED Status DisplayGeneral DSL LoopType Front Panel LEDsLED is Indicating Testing Accessing the Test MenuMain Menu→ Test TestMain Menu→ Test→ Network & DSX-1 Tests Running Network TestsNetwork & DSX-1 Tests Line Loopback Repeater Loopback DTE Loopback Remote Send Line Loopback Send and Monitor Device Tests Lamp TestMain Menu→ Test→ Device Tests Device TestsConfiguration Options Ending an Active TestTelco-Initiated Tests Telco-Initiated Line LoopbackTelco-Initiated Payload Loopback Activation Line Payload Remote Line Deactivation LoopbackTelco-Initiated Remote Line Loopback CAP LIU DSL DSX-1Testing February Messages and Troubleshooting Snmp Traps Options Configuring Snmp TrapsNMS Device Messages Device Messages 1 What Message Indicates What To DoDevice Messages 2 What Message Indicates What To Do Troubleshooting Troubleshooting Symptom Possible Cause SolutionsMessages and Troubleshooting February ATI Access Levels SecurityCreating a Login Administer LoginsDeleting a Login On the Login Entry Screen, for EnterControlling Snmp Access Assigning Snmp Community Names and Access TypesManagement Options, in Appendix A, Configuration Options Configuration Options, toConfigurations Not Running IP Conservative Software All ConfigurationsIP Addressing Selecting an IP Addressing SchemeIP Addressing Example Peer IP Address AssignmentsConfiguration Options Configuration Changes in , Initial Startup and ConfigurationMain Menu→ Configuration→ Current Configuration→ Network Excessive Error Rate ThresholdNetwork Interface Options Table A-1. Network Interface Options 1DSL Line Rate Possible Settings 400, 528, 784, 1040 Table A-1. Network Interface Options 2AutoRate Circuit IdentifierMain Menu→ Configuration→ Current Configuration → DSX-1 DSX-1 Interface OptionsDSX-1 Interface Options ESFTable A-2. DSX-1 Interface Options 1 Port StatusLine Framing Line CodingTable A-2. DSX-1 Interface Options 2 Send AIS on Network FailureSend All Ones on DSX-1 Failure Primary Clock SourceMain Menu→ Configuration→ Current Configuration→ Copy Ports Copy Ports OptionsTable A-3. Copy Ports Options From Port nMain Menu→ Configuration→ Current Configuration→ System System OptionsSystem Options LTUTable A-4. System Options Management and Communication Menu Telnet Session OptionsTelnet Login Required Session Access LevelInactivity Timeout Table A-5. Telnet Session Options 1Main Menu→ Configuration→ Current Configuration→ General Snmp Management OptionsTable A-5. Telnet Session Options 2 Disconnect Time MinutesName 1 Access Name 2 AccessTable A-6. General Snmp Management Options Snmp ManagementSnmp NMS Security Options Snmp NMS Security OptionsTable A-7. Snmp NMS Security Options Access LevelNMS IP Validation Snmp Trap Options Table A-8. Snmp Trap Options 1 Snmp TrapsNumber of Trap Managers NMS n DestinationLink Traps Possible Settings Disable, Up, Down, Both Table A-8. Snmp Trap Options 2Enterprise Specific Traps Link Traps InterfacesAuthenticationFailure Standards Compliance for Snmp TrapsSnmp Traps WarmStartLinkUp and linkDown LinkUp/DownT Variable-BindingsEnterprise-Specific Traps DSL Network IfIndex RFC Front Panel 50-pin DTE Connector Pinouts Connector Pin Assignments50-Pin Connector DSX-1 Port Pinout Function Connector Pin Assignments February Technical Specifications Specifications CriteriaTechnical Specifications February Glossary 511Bridged tap COM portFactory defaults EIA-530-AEthernet FrameReset 703704 IP addressYellow Alarm RouterRS-449 TelnetIndex IN-1IN-2 IN-3 IN-4 IN-5 IN-6