Paradyne 8784 manual DSL Network IfIndex RFC

Page 96

B. Standards Compliance for SNMP Traps

The tests that affect the enterpriseTestStart, enterpriseTestStop, and the variable-bindings are different for each particular interface. Diagnostic tests are only supported on the physical T1 network and user data port interfaces. The specific tests and variable-bindings are described in the following table:

 

enterpriseTestStart/Stop

 

 

Interface

Variable-Bindings

Possible Cause

 

 

 

DSL Network

ifIndex (RFC 1573)

TenterpriseTest Start – Any

 

ifAdminStatus (RFC 1573)

one of the following tests is

 

active on the interface:

 

 

 

 

ifOperStatus (RFC 1573)

Line Loopback

 

TifType (RFC 1573)

Repeater Loopback

 

ifTestType (RFC 1573)

Remote Line Loopback

 

T

Send and Monitor 511

 

The following objects control tests

 

in SNMP-managed devices:

enterpriseTest Stop – No

 

– noTest – Stops the test in

tests currently running on

 

 

progress.

the interface.

 

– testLoopLLB – Initiates a Local

 

 

 

 

Loopback.

 

 

 

testLoopRLB – Initiates a

 

 

 

 

Remote Loopback.

 

 

 

testSendMon511 – Initiates a

 

 

 

 

Send and Monitor 511 test.

 

 

 

– testSendLLBUp – Initiates an

 

 

 

 

LLB Up message to the

 

 

 

 

remote unit.

 

 

 

testSendLLBDown – Initiates

 

 

 

 

an LLB Down message to the

 

 

 

 

remote unit.

 

 

 

 

 

DSX-1

ifIndex (RFC 1573)

TenterpriseTest Start – Any

 

ifAdminStatus (RFC 1573)

one of the following tests is

 

active on the interface:

 

 

 

 

TifOperStatus (RFC 1573)

Data Terminal

 

ifTestType (RFC 1573)

 

Loopback

 

Repeater Loopback

 

The following objects control tests

 

testLoop RLB – initiates

 

in SNMP-managed devices:

 

– noTest – Stops the test in

 

a Repeater Loopback

 

testLoop DTLB –

 

 

progress.

 

testLoopExternalDTE

 

initiates a DSX-1 DTE

 

T

Loopback

 

 

 

enterpriseTest Stop – No

 

 

 

tests currently running on

 

 

 

the interface.

 

 

 

 

 

B-4

February 2001

8784-A2-GB20-30

Image 96
Contents Hotwire 8784 TDM Sdsl Termination Unit Copyright 2001 Paradyne Corporation All rights reserved Important Safety Instructions United States EMI Notice Contents Initial Startup and Configuration Monitoring the UnitFebruary Testing Messages and TroubleshootingSecurity IP Addressing TConfiguration Options Connector Pin AssignmentsTechnical Specifications Glossary Index Standards ComplianceT for Snmp TrapsAbout This Guide Document Purpose and Intended AudienceDocument Summary Product-Related Documents Document Number Document TitleAbout the Hotwire Termination Unit TDM Sdsl OverviewHotwire 8784 Termination Unit Features Network Configuration Customer Premises CPCO Site Snmp Management Capabilities Management Information Base MIB SupportSnmp Trap Support NetworkUsing the Asynchronous Terminal Interface User Interface AccessManagement Serial Port Settings Logging In to the Hotwire Dslam LoginInitiating an ATI Session Select Main MenuMenu Hierarchy SnmpMain Menu→ Configuration → Current Configuration → Network Screen Work AreasFunction KeysNavigating the Screens Keyboard KeysPress Function Keys For the screen Function Select Press Enter toSwitching Between Screen Work Areas ExampleEnding an ATI Session Exiting From the Dslam SessionUsing the Asynchronous Terminal Interface February Initial Startup and Configuration OverviewEntering Identity Information Main Menu→ Control→ Change IdentityIdentity Configuring the Unit Main Menu→ Configuration Load Configuration FromLoad Configuration from Current and Default Factory Configurations Configuration EDIT/DISPLAYIf you select Then Configuration Loader Select To Access To ConfigureMain Menu→ Configuration → Configuration Loader Configuration LoaderCompleted successfully Saving Configuration Changes Save ConfigurationDownloading Firmware Main Menu→ Control → Download CodeDownload Code DSL1Apply Download AutoRate Feature Main Menu→ Configuration→ Current Configuration → NetworkDisabling AutoRate Restoring Access to the User Interface Resetting AutoRateMain Menu→ Control→ Reset AutoRate Select Configuration→ DSL Cards → Reset SlotResetting the Unit Main Menu→ Control→ Reset DeviceMonitoring the Unit What to MonitorViewing System and Test Status Main Menu→ Status→ System and Test StatusSystem and Test Status Health and Status SELF-TEST Results Health and Status Messages YyyyyyyyMonitoring the Unit Self-Test Results Messages Test Status MessagesTest Status Messages Meaning Viewing Network Error Statistics Network Error StatisticsPerformance Statistics SES Severely Errored Seconds Seconds during which more than Field ContainsViewing Network Performance Statistics This Field Contains Viewing Current Network Performance Current Network Performance StatisticsSES FebeViewing DSX-1 Performance Statistics Main Menu→ Status→ Performance Statistics→ DSX-1 StatisticsDSX-1 Performance Statistics This Field Contains Viewing LED Status DisplayGeneral DSL LoopFront Panel LEDs TypeLED is Indicating Testing Accessing the Test MenuMain Menu→ Test TestRunning Network Tests Main Menu→ Test→ Network & DSX-1 TestsNetwork & DSX-1 Tests Line Loopback Repeater Loopback DTE Loopback Remote Send Line Loopback Send and Monitor Device Tests Lamp TestMain Menu→ Test→ Device Tests Device TestsConfiguration Options Ending an Active TestTelco-Initiated Tests Telco-Initiated Line LoopbackTelco-Initiated Payload Loopback Activation Line Payload Remote Line Deactivation LoopbackTelco-Initiated Remote Line Loopback CAP LIU DSL DSX-1Testing February Messages and Troubleshooting Configuring Snmp Traps Snmp Traps OptionsNMS Device Messages Device Messages 1 What Message Indicates What To DoDevice Messages 2 What Message Indicates What To Do Troubleshooting Troubleshooting Symptom Possible Cause SolutionsMessages and Troubleshooting February ATI Access Levels SecurityCreating a Login Administer LoginsDeleting a Login On the Login Entry Screen, for EnterControlling Snmp Access Assigning Snmp Community Names and Access TypesManagement Options, in Appendix A, Configuration Options Configuration Options, toConfigurations Not Running IP Conservative Software All ConfigurationsIP Addressing Selecting an IP Addressing SchemeIP Addressing Example Peer IP Address AssignmentsConfiguration Options Configuration Changes in , Initial Startup and ConfigurationMain Menu→ Configuration→ Current Configuration→ Network Excessive Error Rate ThresholdNetwork Interface Options Table A-1. Network Interface Options 1DSL Line Rate Possible Settings 400, 528, 784, 1040 Table A-1. Network Interface Options 2AutoRate Circuit IdentifierMain Menu→ Configuration→ Current Configuration → DSX-1 DSX-1 Interface OptionsDSX-1 Interface Options ESFTable A-2. DSX-1 Interface Options 1 Port StatusLine Framing Line CodingTable A-2. DSX-1 Interface Options 2 Send AIS on Network FailureSend All Ones on DSX-1 Failure Primary Clock SourceMain Menu→ Configuration→ Current Configuration→ Copy Ports Copy Ports OptionsTable A-3. Copy Ports Options From Port nMain Menu→ Configuration→ Current Configuration→ System System OptionsSystem Options LTUTable A-4. System Options Management and Communication Menu Telnet Session OptionsTelnet Login Required Session Access LevelInactivity Timeout Table A-5. Telnet Session Options 1Main Menu→ Configuration→ Current Configuration→ General Snmp Management OptionsTable A-5. Telnet Session Options 2 Disconnect Time MinutesName 1 Access Name 2 AccessTable A-6. General Snmp Management Options Snmp ManagementSnmp NMS Security Options Snmp NMS Security OptionsAccess Level Table A-7. Snmp NMS Security OptionsNMS IP Validation Snmp Trap Options Table A-8. Snmp Trap Options 1 Snmp TrapsNumber of Trap Managers NMS n DestinationLink Traps Possible Settings Disable, Up, Down, Both Table A-8. Snmp Trap Options 2Enterprise Specific Traps Link Traps InterfacesAuthenticationFailure Standards Compliance for Snmp TrapsSnmp Traps WarmStartLinkUp and linkDown LinkUp/DownT Variable-BindingsEnterprise-Specific Traps DSL Network IfIndex RFC Connector Pin Assignments Front Panel 50-pin DTE Connector Pinouts50-Pin Connector DSX-1 Port Pinout Function Connector Pin Assignments February Technical Specifications Specifications CriteriaTechnical Specifications February Glossary 511Bridged tap COM portFactory defaults EIA-530-AEthernet FrameReset 703704 IP addressYellow Alarm RouterRS-449 TelnetIndex IN-1IN-2 IN-3 IN-4 IN-5 IN-6