Patton electronic 3088 Series System reset mode, Software upgrades, DIP switch settings

Page 23

Model 3088 Series User Manual

2 • Configuration

 

 

The two sets of DIP switches on the underside of the Model 3088 are referred to as S1 and S2. As shown in figure 5, DIP switch orientation with respect to ON and OFF positions is consistent for all switches.

ON

1 2 3 4 5 6 7 8

ON

OFF

Figure 5. Close-up of configuration switches (all sets are identical appearance)

System reset mode

To enter system reset mode, switch all DIP switches to the OFF position and power cycle the unit. You can use a VT100 emulator configured for 19,200 kbps/1 stop bit/ no parity/ XON-XOFF flow control to access the console. Upon restart, you will see the message “Reset Mode”.

System reset mode provides two functions:

Software upgrades

Configuration reset to factory defaults

Software upgrades

The software is upgraded by waiting for the Reset Mode message. Then, the user can send an Intel HEX file supplied by Patton. After the VT100 emulator has finished sending this file, the 3088 will respond with a mes- sage stating how many errors were detected. The user may then set the DIP switches to the desired configura- tion and power cycle the unit to run the upgraded software.

Configuration reset to factory defaults

To recover from a forgotten password, the user may reset the unit to its factory configuration. After seeing the Reset Mode message, the user should type the ‘*’ key. This will result in a ‘:’ prompt. At the prompt, the user should enter the command reset. This will restore the unit to the factory configuration. The unit can then be restarted with the settings in place.

DIP switch settings

You can configure the 3088 by setting the DIP switches to the desired positions before you power up the Rock- etLink-G. If the DIP switches are set to anything other than all OFF or all ON, the RocketLink-G will operate in DIP switch configuration mode. Once the device is powered up and operating in DIP switch configuration mode, you cannot change configuration by any method until you power it down again.

Introduction

23

Image 23
Contents Shdsl NTU with fixed serial interface Mailsupport@patton.com Summary Table of Contents Table of Contents RocketLink-G installation Software Upgrade Factory default values List of Figures List of Tables Structure About this guideAudience Impaired functioning PrecautionsSafety when working with electricity Convention Meaning Typographical conventions used in this documentGeneral observations General conventionsGeneral information Chapter contentsSerial interface types FeaturesRocketLink-G 3088 overview External AC universal power supply Power input connectorExternal 48 VDC power supply Configuration Introduction Software CLI configurationHardware DIP-switch configuration E1-CRC Parameter Description Possible ValuesAMI 3088 K/T Models Configuring the DIP switchesDIP switch settings System reset modeSoftware upgrades Configuration reset to factory defaultsPosition Function S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 Data Rate kbps 2368 S2-3 Annex A/B Models 3088/CA and D S2-4 through S2-5 Clock Mode Models 3088/CA and DS1-8 TX Clock RocketLink-G models 3088/CA and 3088/D S2-2 Line Probe Models 3088/CA and DCPE-Side Modem CO-Side Modem S2-6 SettingS2-6 DTE Loops RocketLink-G models 3088/CA only Model 3088/K and 3088/T S1 DIP-Switch Functions 128 S2-3 Annex A/B Models 3088/K and 3088/T S2-4 through S2-5 Clock Mode Models 3088/K and 3088/TS1-7 and S1-8 Line Build Out Models 3088/K and 3088/T S2-2 Line Code Models 3088/K and 3088/TS2-6 S2-7 S2-8 Line Type S2-6 through S2-8 Line Type Models 3088/K and 3088/TConsole ReservedConfiguration DSL Line Condition Good or Poor Help Commands DSL Configuration Commands System Configuration CommandsSystem Status Commands Startup Delay Interval Interval totint DSL Status CommandDSL Clear Errcntrs Command T1/E1 Configuration CommandsRemote Console T1/E1 Status CommandsExample Command Line Interface Session RocketLink Plug ‘n’ Play Typical RocketLink Plug ‘n’ Play Application RocketLink-G installation Connecting the twisted pair interface InstallationConnecting the Model 3088/CA V.35 to a DCE device Connecting the Model 3088/CA V.35 serial interfaceConnecting the Model 3088/CA V.35 to a DTE device Connecting the Model 3088/D X.21 to a DCE or DTE device Connecting the Model 3088/D X.21 serial interfaceOpening the Case Connecting the Model 3088/D to X.21 DTE or DCEConnecting the Model 3088/K to an E1 Network Connecting the Model 3088/K serial interfaceConnect twisted pair 120 ohm to E1 network Connecting dual coaxial cable 75 ohm to E1 networkConnect Twisted Pair 100 ohm to T1 Network Connecting the Model 3088/T T1 serial interfaceExternal AC universal power supply Connecting powerTo Power Supply Jack DC PowerOperation DSL Green Power-upPower Green LED status monitorsTest modes Term Green Models C and DTM/ER Red LOS Red Models K and TPatterns LoopbacksRemote console operation Establishing a Remote Console Session How to ConnectLog in to 3088 Near End How to DisconnectRemote control session with LAL diagram Differences in Local and Remote Control Session BehaviorRemote console operation Software Upgrade Software Upgrade Reset configuration to factory defaults Reset configuration to factory defaults Contacting Patton for assistance Patton support headquarters in the USA Warranty coverageContact information RMA numbers Out-of-warranty serviceReturns for credit Return for credit policyAppendix a Compliance information Pstn Regulatory SafetyCompliance FCC Part 68 Acta StatementCE Declaration of Conformity Radio and TV Interference FCC PartIndustry Canada Notice Authorized European Representative Appendix B Specifications DTE rate Serial connectorDiagnostics Clocking modesTerm Green ConfigurationPower and power supply specifications Line interface Transmission lineLine coding Line rates DSL lineAppendix C Factory default values Parameter Default value Factory default values for software-configurable parametersB8ZS Appendix D Factory replacement parts and accessories Model # Description Factory replacement parts and accessoriesAppendix E Interface pinouts T1/E1 interface Pin # SignalRJ-11 non-shielded DSL port InterfaceRS-232 console interface pin assignments Sub-15 female connector DTE/DCE orientation

3088 Series specifications

The Patton Electronics 3088 Series is a robust solution tailored for businesses seeking reliable and efficient data connectivity. This series encompasses a range of devices designed to meet the growing demands of modern networking, particularly in environments that require resilient and secure communications.

One of the standout features of the 3088 Series is its versatile connectivity options. The devices support multiple interfaces, including Ethernet and serial connections, allowing for easy integration into existing infrastructures. This flexibility enables organizations to transition smoothly from outdated systems to state-of-the-art technology without extensive reconfiguration.

The 3088 Series also employs advanced protocols to ensure data integrity and security. Mechanisms such as error correction and data encryption are built into the architecture, safeguarding sensitive information from potential breaches. This is particularly important for industries that handle private data, such as healthcare or finance, where compliance with regulations is critical.

In addition to its connectivity features, the 3088 Series prioritizes ease of use and management. Each device is designed with user-friendly interfaces that simplify configuration and monitoring tasks. Comprehensive management options allow network administrators to efficiently track performance, modify settings, and troubleshoot issues remotely, thereby reducing downtime and maintaining productivity.

Furthermore, the 3088 Series emphasizes durability and reliability, making it suitable for demanding applications. Built using high-quality materials, these devices are engineered to withstand environmental stresses, making them ideal for industrial and outdoor deployments. This resilience contributes to lower maintenance costs and longer lifecycle.

The series is also designed with scalability in mind. As businesses grow and their networking needs evolve, the 3088 Series can adapt accordingly. This feature ensures that organizations can expand their capabilities without completely overhauling their systems, providing a cost-effective long-term solution.

Overall, the Patton Electronics 3088 Series stands out as a powerful and flexible platform for data communications. Its combination of versatile connectivity, high-level security features, ease of management, durability, and scalability render it an ideal choice for organizations looking to future-proof their networking infrastructures. As businesses continue to evolve in a digitally driven landscape, the 3088 Series provides a reliable backbone to support their communication needs.