Patton electronic 3088 Series Opening the Case, Connecting the Model 3088/D to X.21 DTE or DCE

Page 45

Model 3088 Series User Manual

3 • RocketLink-G installation

 

 

such as a modem or multiplexer. When connecting the X.21 interface of the Model 3088/D to your DTE or DCE device, use an X.21 straight-through cable (See figure 10).

-G

NTU

 

RocketLink™Console

 

 

TM/ERR

Power

DSL

Terminal

 

 

Remote Model 3088

DSL Span

-G

NTU

 

RocketLink™Console

Straight-Through 15-pin

D-Sub CableRouter (DTE)

OR

Mux (DCE)

 

 

TM/ERR

Power

DSL

Terminal

 

 

Model 3088/D (DCE or DTE)

Figure 10. Connecting the Model 3088/D to X.21 DTE or DCE

To change the DCE/DTE orientation from the default position (DCE), you must open the case Model 3088/D case.

Opening the Case

To open the Model 3088/D case, insert a flat head screw driver into an open slot on both sides of the case, as in figure 11. Twist the screw driver head slightly and the top half of the case will separate from the lower half, as in figure 11. Be careful not to damage the PC-board mounted components.

Figure 11. Opening the 3088 case with a small screwdriver

Installation

45

Image 45
Contents Shdsl NTU with fixed serial interface Mailsupport@patton.com Summary Table of Contents Table of Contents RocketLink-G installation Software Upgrade Factory default values List of Figures List of Tables About this guide AudienceStructure Impaired functioning PrecautionsSafety when working with electricity General observations Typographical conventions used in this documentGeneral conventions Convention MeaningGeneral information Chapter contentsFeatures RocketLink-G 3088 overviewSerial interface types External AC universal power supply Power input connectorExternal 48 VDC power supply Configuration Software CLI configuration Hardware DIP-switch configurationIntroduction E1-CRC Parameter Description Possible ValuesAMI 3088 K/T Models Configuring the DIP switchesSoftware upgrades System reset modeConfiguration reset to factory defaults DIP switch settingsPosition Function S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 Data Rate kbps 2368 S1-8 TX Clock RocketLink-G models 3088/CA and 3088/D S2-4 through S2-5 Clock Mode Models 3088/CA and DS2-2 Line Probe Models 3088/CA and D S2-3 Annex A/B Models 3088/CA and DS2-6 Setting S2-6 DTE Loops RocketLink-G models 3088/CA onlyCPE-Side Modem CO-Side Modem Model 3088/K and 3088/T S1 DIP-Switch Functions 128 S1-7 and S1-8 Line Build Out Models 3088/K and 3088/T S2-4 through S2-5 Clock Mode Models 3088/K and 3088/TS2-2 Line Code Models 3088/K and 3088/T S2-3 Annex A/B Models 3088/K and 3088/TConsole S2-6 through S2-8 Line Type Models 3088/K and 3088/TReserved S2-6 S2-7 S2-8 Line TypeConfiguration DSL Line Condition Good or Poor Help Commands System Configuration Commands System Status CommandsDSL Configuration Commands DSL Clear Errcntrs Command DSL Status CommandT1/E1 Configuration Commands Startup Delay Interval Interval totintT1/E1 Status Commands Example Command Line Interface SessionRemote Console RocketLink Plug ‘n’ Play Typical RocketLink Plug ‘n’ Play Application RocketLink-G installation Connecting the twisted pair interface InstallationConnecting the Model 3088/CA V.35 serial interface Connecting the Model 3088/CA V.35 to a DTE deviceConnecting the Model 3088/CA V.35 to a DCE device Connecting the Model 3088/D X.21 to a DCE or DTE device Connecting the Model 3088/D X.21 serial interfaceOpening the Case Connecting the Model 3088/D to X.21 DTE or DCEConnecting the Model 3088/K to an E1 Network Connecting the Model 3088/K serial interfaceConnect twisted pair 120 ohm to E1 network Connecting dual coaxial cable 75 ohm to E1 networkConnect Twisted Pair 100 ohm to T1 Network Connecting the Model 3088/T T1 serial interfaceExternal AC universal power supply Connecting powerTo Power Supply Jack DC PowerOperation Power Green Power-upLED status monitors DSL GreenTM/ER Red Term Green Models C and DLOS Red Models K and T Test modesPatterns LoopbacksRemote console operation Establishing a Remote Console Session How to ConnectLog in to 3088 Near End How to DisconnectRemote control session with LAL diagram Differences in Local and Remote Control Session BehaviorRemote console operation Software Upgrade Software Upgrade Reset configuration to factory defaults Reset configuration to factory defaults Contacting Patton for assistance Warranty coverage Contact informationPatton support headquarters in the USA Returns for credit Out-of-warranty serviceReturn for credit policy RMA numbersAppendix a Compliance information Compliance SafetyFCC Part 68 Acta Statement Pstn RegulatoryRadio and TV Interference FCC Part Industry Canada NoticeCE Declaration of Conformity Authorized European Representative Appendix B Specifications Diagnostics Serial connectorClocking modes DTE rateConfiguration Power and power supply specificationsTerm Green Line coding Transmission lineLine rates DSL line Line interfaceAppendix C Factory default values Parameter Default value Factory default values for software-configurable parametersB8ZS Appendix D Factory replacement parts and accessories Model # Description Factory replacement parts and accessoriesAppendix E Interface pinouts RJ-11 non-shielded DSL port Pin # SignalInterface T1/E1 interfaceRS-232 console interface pin assignments Sub-15 female connector DTE/DCE orientation

3088 Series specifications

The Patton Electronics 3088 Series is a robust solution tailored for businesses seeking reliable and efficient data connectivity. This series encompasses a range of devices designed to meet the growing demands of modern networking, particularly in environments that require resilient and secure communications.

One of the standout features of the 3088 Series is its versatile connectivity options. The devices support multiple interfaces, including Ethernet and serial connections, allowing for easy integration into existing infrastructures. This flexibility enables organizations to transition smoothly from outdated systems to state-of-the-art technology without extensive reconfiguration.

The 3088 Series also employs advanced protocols to ensure data integrity and security. Mechanisms such as error correction and data encryption are built into the architecture, safeguarding sensitive information from potential breaches. This is particularly important for industries that handle private data, such as healthcare or finance, where compliance with regulations is critical.

In addition to its connectivity features, the 3088 Series prioritizes ease of use and management. Each device is designed with user-friendly interfaces that simplify configuration and monitoring tasks. Comprehensive management options allow network administrators to efficiently track performance, modify settings, and troubleshoot issues remotely, thereby reducing downtime and maintaining productivity.

Furthermore, the 3088 Series emphasizes durability and reliability, making it suitable for demanding applications. Built using high-quality materials, these devices are engineered to withstand environmental stresses, making them ideal for industrial and outdoor deployments. This resilience contributes to lower maintenance costs and longer lifecycle.

The series is also designed with scalability in mind. As businesses grow and their networking needs evolve, the 3088 Series can adapt accordingly. This feature ensures that organizations can expand their capabilities without completely overhauling their systems, providing a cost-effective long-term solution.

Overall, the Patton Electronics 3088 Series stands out as a powerful and flexible platform for data communications. Its combination of versatile connectivity, high-level security features, ease of management, durability, and scalability render it an ideal choice for organizations looking to future-proof their networking infrastructures. As businesses continue to evolve in a digitally driven landscape, the 3088 Series provides a reliable backbone to support their communication needs.