Patton electronic 3088 Series S2-6 through S2-8 Line Type Models 3088/K and 3088/T, Console

Page 32

Model 3088 Series User Manual2 • Configuration

Table 18. S2-4 and S2-5 Clock Mode Settings

S2-4

S2-5

Clock Mode

Description

 

 

 

 

OFF

OFF

 

Reserved

 

 

 

 

S2-6 through S2-8: Line Type (Models 3088/K and 3088/T)

The RocketLink-G has two different line types, T1 and E1. T1 has three different settings, and E1 has five dif- ferent settings.

Table 19. S2-6 through S2-8 Line Type Settings

S2-6

S2-7

S2-8

Line Type

 

 

 

 

ON

ON

ON

T1-Unframeda

OFF

ON

ON

T1-SuperFramea

ON

OFF

ON

T1-ExtendedSuperFramea

OFF

OFF

ON

E1-Unframed (G.703 Clear Channel)

 

 

 

 

ON

ON

OFF

E1-Structured (G.704)

OFF

ON

OFF

E1-CRC

 

 

 

 

ON

OFF

OFF

E1-Multiframe

OFF

OFF

OFF

E1-CRC Multiframe

 

 

 

 

a.For T1 operation, pass framing must be enabled (see Pass Framing param- eter in table 2 on page 20 for details).

Console

The 3088 offers a console command line interface. To access the console, use a VT100 emulator configured to 19,200 kbps, 1 stop bit, no parity, and XON-XOFF flow control. Log into the unit using the default pass- word. No username will be needed.

Note For software release 2.1.2, log in with the default password patton.

For software release 2.1.3, log in with the default password superuser.

Through the console, the following variables can be configured:

Password: The password used to login to the console.

Circuit ID: The circuit ID communicated to other units via EOC. EOC (Embedded Operations Channel) is an out-of-band channel specified in the G.991.2 standard for SHDSL. We use standard EOC messages for our remote loopback. The 3088 also supports proprietary EOC messages that allow a 3096RC to con- figure it.

Clock Mode: The following options are available:

-Internal: The internal oscillator in the 3088 provides the clock to both the serial/T1/E1 and DSL interfaces.

-Network: The T1/E1 interface provides the clock for the DSL interface (T1/E1 only).

Introduction

32

Image 32
Contents Shdsl NTU with fixed serial interface Mailsupport@patton.com Summary Table of Contents Table of Contents RocketLink-G installation Software Upgrade Factory default values List of Figures List of Tables Structure About this guideAudience Precautions Impaired functioningSafety when working with electricity Typographical conventions used in this document General observationsGeneral conventions Convention MeaningChapter contents General informationSerial interface types FeaturesRocketLink-G 3088 overview Power input connector External AC universal power supplyExternal 48 VDC power supply Configuration Introduction Software CLI configurationHardware DIP-switch configuration Parameter Description Possible Values E1-CRCAMI Configuring the DIP switches 3088 K/T ModelsSystem reset mode Software upgradesConfiguration reset to factory defaults DIP switch settingsPosition Function S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 Data Rate kbps 2368 S2-4 through S2-5 Clock Mode Models 3088/CA and D S1-8 TX Clock RocketLink-G models 3088/CA and 3088/DS2-2 Line Probe Models 3088/CA and D S2-3 Annex A/B Models 3088/CA and DCPE-Side Modem CO-Side Modem S2-6 SettingS2-6 DTE Loops RocketLink-G models 3088/CA only Model 3088/K and 3088/T S1 DIP-Switch Functions 128 S2-4 through S2-5 Clock Mode Models 3088/K and 3088/T S1-7 and S1-8 Line Build Out Models 3088/K and 3088/TS2-2 Line Code Models 3088/K and 3088/T S2-3 Annex A/B Models 3088/K and 3088/TS2-6 through S2-8 Line Type Models 3088/K and 3088/T ConsoleReserved S2-6 S2-7 S2-8 Line TypeConfiguration DSL Line Condition Good or Poor Help Commands DSL Configuration Commands System Configuration CommandsSystem Status Commands DSL Status Command DSL Clear Errcntrs CommandT1/E1 Configuration Commands Startup Delay Interval Interval totintRemote Console T1/E1 Status CommandsExample Command Line Interface Session RocketLink Plug ‘n’ Play Typical RocketLink Plug ‘n’ Play Application RocketLink-G installation Installation Connecting the twisted pair interfaceConnecting the Model 3088/CA V.35 to a DCE device Connecting the Model 3088/CA V.35 serial interfaceConnecting the Model 3088/CA V.35 to a DTE device Connecting the Model 3088/D X.21 serial interface Connecting the Model 3088/D X.21 to a DCE or DTE deviceConnecting the Model 3088/D to X.21 DTE or DCE Opening the CaseConnecting the Model 3088/K serial interface Connecting the Model 3088/K to an E1 NetworkConnecting dual coaxial cable 75 ohm to E1 network Connect twisted pair 120 ohm to E1 networkConnecting the Model 3088/T T1 serial interface Connect Twisted Pair 100 ohm to T1 NetworkConnecting power External AC universal power supplyDC Power To Power Supply JackOperation Power-up Power GreenLED status monitors DSL GreenTerm Green Models C and D TM/ER RedLOS Red Models K and T Test modesLoopbacks PatternsRemote console operation How to Connect Establishing a Remote Console SessionHow to Disconnect Log in to 3088 Near EndDifferences in Local and Remote Control Session Behavior Remote control session with LAL diagramRemote console operation Software Upgrade Software Upgrade Reset configuration to factory defaults Reset configuration to factory defaults Contacting Patton for assistance Patton support headquarters in the USA Warranty coverageContact information Out-of-warranty service Returns for creditReturn for credit policy RMA numbersAppendix a Compliance information Safety ComplianceFCC Part 68 Acta Statement Pstn RegulatoryCE Declaration of Conformity Radio and TV Interference FCC PartIndustry Canada Notice Authorized European Representative Appendix B Specifications Serial connector DiagnosticsClocking modes DTE rateTerm Green ConfigurationPower and power supply specifications Transmission line Line codingLine rates DSL line Line interfaceAppendix C Factory default values Factory default values for software-configurable parameters Parameter Default valueB8ZS Appendix D Factory replacement parts and accessories Factory replacement parts and accessories Model # DescriptionAppendix E Interface pinouts Pin # Signal RJ-11 non-shielded DSL portInterface T1/E1 interfaceSub-15 female connector DTE/DCE orientation RS-232 console interface pin assignments

3088 Series specifications

The Patton Electronics 3088 Series is a robust solution tailored for businesses seeking reliable and efficient data connectivity. This series encompasses a range of devices designed to meet the growing demands of modern networking, particularly in environments that require resilient and secure communications.

One of the standout features of the 3088 Series is its versatile connectivity options. The devices support multiple interfaces, including Ethernet and serial connections, allowing for easy integration into existing infrastructures. This flexibility enables organizations to transition smoothly from outdated systems to state-of-the-art technology without extensive reconfiguration.

The 3088 Series also employs advanced protocols to ensure data integrity and security. Mechanisms such as error correction and data encryption are built into the architecture, safeguarding sensitive information from potential breaches. This is particularly important for industries that handle private data, such as healthcare or finance, where compliance with regulations is critical.

In addition to its connectivity features, the 3088 Series prioritizes ease of use and management. Each device is designed with user-friendly interfaces that simplify configuration and monitoring tasks. Comprehensive management options allow network administrators to efficiently track performance, modify settings, and troubleshoot issues remotely, thereby reducing downtime and maintaining productivity.

Furthermore, the 3088 Series emphasizes durability and reliability, making it suitable for demanding applications. Built using high-quality materials, these devices are engineered to withstand environmental stresses, making them ideal for industrial and outdoor deployments. This resilience contributes to lower maintenance costs and longer lifecycle.

The series is also designed with scalability in mind. As businesses grow and their networking needs evolve, the 3088 Series can adapt accordingly. This feature ensures that organizations can expand their capabilities without completely overhauling their systems, providing a cost-effective long-term solution.

Overall, the Patton Electronics 3088 Series stands out as a powerful and flexible platform for data communications. Its combination of versatile connectivity, high-level security features, ease of management, durability, and scalability render it an ideal choice for organizations looking to future-proof their networking infrastructures. As businesses continue to evolve in a digitally driven landscape, the 3088 Series provides a reliable backbone to support their communication needs.