Switches S1-7 and S1-8 define the shape of the waveform on the T1 or E1 line, as shown in table 15.

Table 15. S1-7S1-8: Line Build Out Settings

S1-7

S1-8

Line Build Out (E1)

Line Build Out (T1)

 

 

 

 

ON

ON

Pulse-75 Ohm

0.0dB

OFF

ON

Pulse-120 Ohm

-7.5 dB

 

 

 

 

ON

OFF

Not Applicable

-15.0dB

OFF

OFF

Not Applicable

-22.5dB

 

 

 

 

Note 75 Ohms corresponds to the BNC connectors on Model 3088/K.

120 Ohms corresponds to the T1/E1 (RJ-45) interface on Models 3088/K and 3088/T.

S2-2 Line Code (Models 3088/K and 3088/T)

Switch S2-2 defines the T1 or E1 network line coding.

Table 16. S2-2 Line Code Switch Settings

S2-2

T1 Line Code

E1 Line Code

 

 

 

ON

AMI

AMI

OFF

B8ZS

HDB3

 

 

 

S2-3: Annex A/B (Models 3088/K and 3088/T)

Annex A is typically used in North American-like networks, whereas Annex B is typically used in European- like networks. The different annexes specify different PSD (power spectral density) masks because of the differ- ence in T1 and E1 PSDs.

Table 17. S2-3 Annex Type settings

S2-3

Annex

 

 

ON

A

OFF

B

 

 

S2-4 through S2-5: Clock Mode (Models 3088/K and 3088/T))

The RocketLink-G can operate in one of three clock modes: internal, network, or receive-recover.

Table 18. S2-4 and S2-5 Clock Mode Settings

S2-4

S2-5

Clock Mode

Description

 

 

 

 

ON

ON

Internal

The on-board oscillator in the 3088 provides clock for both T1/E1

 

 

 

and DSL lines.

OFF

ON

Network

3088 uses the RX clock from the T1/E1 interface as the clock for

 

 

 

the DSL link.

 

 

 

 

ON

OFF

Receive-Recover

3088 uses the RX clock from the DSL interface as the clock for the

 

 

 

T1/E1 line.

 

 

 

 

Introduction

31

Image 31
Contents Shdsl NTU with fixed serial interface Mailsupport@patton.com Summary Table of Contents Table of Contents RocketLink-G installation Software Upgrade Factory default values List of Figures List of Tables Audience About this guideStructure Impaired functioning PrecautionsSafety when working with electricity Convention Meaning Typographical conventions used in this documentGeneral observations General conventionsGeneral information Chapter contentsRocketLink-G 3088 overview FeaturesSerial interface types External AC universal power supply Power input connectorExternal 48 VDC power supply Configuration Hardware DIP-switch configuration Software CLI configurationIntroduction E1-CRC Parameter Description Possible ValuesAMI 3088 K/T Models Configuring the DIP switchesDIP switch settings System reset modeSoftware upgrades Configuration reset to factory defaultsPosition Function S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 Data Rate kbps 2368 S2-3 Annex A/B Models 3088/CA and D S2-4 through S2-5 Clock Mode Models 3088/CA and DS1-8 TX Clock RocketLink-G models 3088/CA and 3088/D S2-2 Line Probe Models 3088/CA and DS2-6 DTE Loops RocketLink-G models 3088/CA only S2-6 SettingCPE-Side Modem CO-Side Modem Model 3088/K and 3088/T S1 DIP-Switch Functions 128 S2-3 Annex A/B Models 3088/K and 3088/T S2-4 through S2-5 Clock Mode Models 3088/K and 3088/TS1-7 and S1-8 Line Build Out Models 3088/K and 3088/T S2-2 Line Code Models 3088/K and 3088/TS2-6 S2-7 S2-8 Line Type S2-6 through S2-8 Line Type Models 3088/K and 3088/TConsole ReservedConfiguration DSL Line Condition Good or Poor Help Commands System Status Commands System Configuration CommandsDSL Configuration Commands Startup Delay Interval Interval totint DSL Status CommandDSL Clear Errcntrs Command T1/E1 Configuration CommandsExample Command Line Interface Session T1/E1 Status CommandsRemote Console RocketLink Plug ‘n’ Play Typical RocketLink Plug ‘n’ Play Application RocketLink-G installation Connecting the twisted pair interface InstallationConnecting the Model 3088/CA V.35 to a DTE device Connecting the Model 3088/CA V.35 serial interfaceConnecting the Model 3088/CA V.35 to a DCE device Connecting the Model 3088/D X.21 to a DCE or DTE device Connecting the Model 3088/D X.21 serial interfaceOpening the Case Connecting the Model 3088/D to X.21 DTE or DCEConnecting the Model 3088/K to an E1 Network Connecting the Model 3088/K serial interfaceConnect twisted pair 120 ohm to E1 network Connecting dual coaxial cable 75 ohm to E1 networkConnect Twisted Pair 100 ohm to T1 Network Connecting the Model 3088/T T1 serial interfaceExternal AC universal power supply Connecting powerTo Power Supply Jack DC PowerOperation DSL Green Power-upPower Green LED status monitorsTest modes Term Green Models C and DTM/ER Red LOS Red Models K and TPatterns LoopbacksRemote console operation Establishing a Remote Console Session How to ConnectLog in to 3088 Near End How to DisconnectRemote control session with LAL diagram Differences in Local and Remote Control Session BehaviorRemote console operation Software Upgrade Software Upgrade Reset configuration to factory defaults Reset configuration to factory defaults Contacting Patton for assistance Contact information Warranty coveragePatton support headquarters in the USA RMA numbers Out-of-warranty serviceReturns for credit Return for credit policyAppendix a Compliance information Pstn Regulatory SafetyCompliance FCC Part 68 Acta StatementIndustry Canada Notice Radio and TV Interference FCC PartCE Declaration of Conformity Authorized European Representative Appendix B Specifications DTE rate Serial connectorDiagnostics Clocking modesPower and power supply specifications ConfigurationTerm Green Line interface Transmission lineLine coding Line rates DSL lineAppendix C Factory default values Parameter Default value Factory default values for software-configurable parametersB8ZS Appendix D Factory replacement parts and accessories Model # Description Factory replacement parts and accessoriesAppendix E Interface pinouts T1/E1 interface Pin # SignalRJ-11 non-shielded DSL port InterfaceRS-232 console interface pin assignments Sub-15 female connector DTE/DCE orientation

3088 Series specifications

The Patton Electronics 3088 Series is a robust solution tailored for businesses seeking reliable and efficient data connectivity. This series encompasses a range of devices designed to meet the growing demands of modern networking, particularly in environments that require resilient and secure communications.

One of the standout features of the 3088 Series is its versatile connectivity options. The devices support multiple interfaces, including Ethernet and serial connections, allowing for easy integration into existing infrastructures. This flexibility enables organizations to transition smoothly from outdated systems to state-of-the-art technology without extensive reconfiguration.

The 3088 Series also employs advanced protocols to ensure data integrity and security. Mechanisms such as error correction and data encryption are built into the architecture, safeguarding sensitive information from potential breaches. This is particularly important for industries that handle private data, such as healthcare or finance, where compliance with regulations is critical.

In addition to its connectivity features, the 3088 Series prioritizes ease of use and management. Each device is designed with user-friendly interfaces that simplify configuration and monitoring tasks. Comprehensive management options allow network administrators to efficiently track performance, modify settings, and troubleshoot issues remotely, thereby reducing downtime and maintaining productivity.

Furthermore, the 3088 Series emphasizes durability and reliability, making it suitable for demanding applications. Built using high-quality materials, these devices are engineered to withstand environmental stresses, making them ideal for industrial and outdoor deployments. This resilience contributes to lower maintenance costs and longer lifecycle.

The series is also designed with scalability in mind. As businesses grow and their networking needs evolve, the 3088 Series can adapt accordingly. This feature ensures that organizations can expand their capabilities without completely overhauling their systems, providing a cost-effective long-term solution.

Overall, the Patton Electronics 3088 Series stands out as a powerful and flexible platform for data communications. Its combination of versatile connectivity, high-level security features, ease of management, durability, and scalability render it an ideal choice for organizations looking to future-proof their networking infrastructures. As businesses continue to evolve in a digitally driven landscape, the 3088 Series provides a reliable backbone to support their communication needs.