Patton electronic 3088 Series S2-6 DTE Loops RocketLink-G models 3088/CA only, S2-6 Setting

Page 28

Model 3088 Series User Manual

2 • Configuration

 

 

X.21 operation. There are a few things to note about clock modes and X.21 operation.

-One X.21 modem must be set to Receive-Recover.The other X.21 modem must be set to either Internal or External/Network clock mode.

-The X.21 modem that is configured as Receive-Recovermust be DCE.

-The X.21 modem that is configured as Internal must also be DCE, but if it is an External/Network clock, then the modem must be configured as DTE.

Table 10. X.21 Clocking

 

CPE-Side Modem

CO-Side Modem

 

 

 

 

Modem’s

Receive-Recover

Internal

External/Network

X.21

DCE

DCE

x

Orientation

 

 

 

DCE

x

DTE

 

 

 

 

 

S2-6: DTE Loops (RocketLink-G models 3088/CA only)

The V.35 interface provides two pins, one to request an LAL and the other to request an RDL. If DTE loops are enabled, the 3088/CA will start a local loopback or a remote loopback when these pins are asserted. If DTE loops are disabled, these requests will be ignored.

Table 11. S2-6 V.35 Loopback settings

S2-6

Setting

 

 

ON

Enabled

OFF

Disabled

 

 

Introduction

28

Image 28
Contents Shdsl NTU with fixed serial interface Mailsupport@patton.com Summary Table of Contents Table of Contents RocketLink-G installation Software Upgrade Factory default values List of Figures List of Tables Audience About this guideStructure Precautions Impaired functioningSafety when working with electricity Typographical conventions used in this document General observationsGeneral conventions Convention MeaningChapter contents General informationRocketLink-G 3088 overview FeaturesSerial interface types Power input connector External AC universal power supplyExternal 48 VDC power supply Configuration Hardware DIP-switch configuration Software CLI configurationIntroduction Parameter Description Possible Values E1-CRCAMI Configuring the DIP switches 3088 K/T ModelsSystem reset mode Software upgradesConfiguration reset to factory defaults DIP switch settingsPosition Function S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 Data Rate kbps 2368 S2-4 through S2-5 Clock Mode Models 3088/CA and D S1-8 TX Clock RocketLink-G models 3088/CA and 3088/DS2-2 Line Probe Models 3088/CA and D S2-3 Annex A/B Models 3088/CA and DS2-6 DTE Loops RocketLink-G models 3088/CA only S2-6 SettingCPE-Side Modem CO-Side Modem Model 3088/K and 3088/T S1 DIP-Switch Functions 128 S2-4 through S2-5 Clock Mode Models 3088/K and 3088/T S1-7 and S1-8 Line Build Out Models 3088/K and 3088/TS2-2 Line Code Models 3088/K and 3088/T S2-3 Annex A/B Models 3088/K and 3088/TS2-6 through S2-8 Line Type Models 3088/K and 3088/T ConsoleReserved S2-6 S2-7 S2-8 Line TypeConfiguration DSL Line Condition Good or Poor Help Commands System Status Commands System Configuration CommandsDSL Configuration Commands DSL Status Command DSL Clear Errcntrs CommandT1/E1 Configuration Commands Startup Delay Interval Interval totintExample Command Line Interface Session T1/E1 Status CommandsRemote Console RocketLink Plug ‘n’ Play Typical RocketLink Plug ‘n’ Play Application RocketLink-G installation Installation Connecting the twisted pair interfaceConnecting the Model 3088/CA V.35 to a DTE device Connecting the Model 3088/CA V.35 serial interfaceConnecting the Model 3088/CA V.35 to a DCE device Connecting the Model 3088/D X.21 serial interface Connecting the Model 3088/D X.21 to a DCE or DTE deviceConnecting the Model 3088/D to X.21 DTE or DCE Opening the CaseConnecting the Model 3088/K serial interface Connecting the Model 3088/K to an E1 NetworkConnecting dual coaxial cable 75 ohm to E1 network Connect twisted pair 120 ohm to E1 networkConnecting the Model 3088/T T1 serial interface Connect Twisted Pair 100 ohm to T1 NetworkConnecting power External AC universal power supplyDC Power To Power Supply JackOperation Power-up Power GreenLED status monitors DSL GreenTerm Green Models C and D TM/ER RedLOS Red Models K and T Test modesLoopbacks PatternsRemote console operation How to Connect Establishing a Remote Console SessionHow to Disconnect Log in to 3088 Near EndDifferences in Local and Remote Control Session Behavior Remote control session with LAL diagramRemote console operation Software Upgrade Software Upgrade Reset configuration to factory defaults Reset configuration to factory defaults Contacting Patton for assistance Contact information Warranty coveragePatton support headquarters in the USA Out-of-warranty service Returns for creditReturn for credit policy RMA numbersAppendix a Compliance information Safety ComplianceFCC Part 68 Acta Statement Pstn RegulatoryIndustry Canada Notice Radio and TV Interference FCC PartCE Declaration of Conformity Authorized European Representative Appendix B Specifications Serial connector DiagnosticsClocking modes DTE ratePower and power supply specifications ConfigurationTerm Green Transmission line Line codingLine rates DSL line Line interfaceAppendix C Factory default values Factory default values for software-configurable parameters Parameter Default valueB8ZS Appendix D Factory replacement parts and accessories Factory replacement parts and accessories Model # DescriptionAppendix E Interface pinouts Pin # Signal RJ-11 non-shielded DSL portInterface T1/E1 interfaceSub-15 female connector DTE/DCE orientation RS-232 console interface pin assignments

3088 Series specifications

The Patton Electronics 3088 Series is a robust solution tailored for businesses seeking reliable and efficient data connectivity. This series encompasses a range of devices designed to meet the growing demands of modern networking, particularly in environments that require resilient and secure communications.

One of the standout features of the 3088 Series is its versatile connectivity options. The devices support multiple interfaces, including Ethernet and serial connections, allowing for easy integration into existing infrastructures. This flexibility enables organizations to transition smoothly from outdated systems to state-of-the-art technology without extensive reconfiguration.

The 3088 Series also employs advanced protocols to ensure data integrity and security. Mechanisms such as error correction and data encryption are built into the architecture, safeguarding sensitive information from potential breaches. This is particularly important for industries that handle private data, such as healthcare or finance, where compliance with regulations is critical.

In addition to its connectivity features, the 3088 Series prioritizes ease of use and management. Each device is designed with user-friendly interfaces that simplify configuration and monitoring tasks. Comprehensive management options allow network administrators to efficiently track performance, modify settings, and troubleshoot issues remotely, thereby reducing downtime and maintaining productivity.

Furthermore, the 3088 Series emphasizes durability and reliability, making it suitable for demanding applications. Built using high-quality materials, these devices are engineered to withstand environmental stresses, making them ideal for industrial and outdoor deployments. This resilience contributes to lower maintenance costs and longer lifecycle.

The series is also designed with scalability in mind. As businesses grow and their networking needs evolve, the 3088 Series can adapt accordingly. This feature ensures that organizations can expand their capabilities without completely overhauling their systems, providing a cost-effective long-term solution.

Overall, the Patton Electronics 3088 Series stands out as a powerful and flexible platform for data communications. Its combination of versatile connectivity, high-level security features, ease of management, durability, and scalability render it an ideal choice for organizations looking to future-proof their networking infrastructures. As businesses continue to evolve in a digitally driven landscape, the 3088 Series provides a reliable backbone to support their communication needs.