2 • Configuration

 

 

tx fifo full: 0

tx fifo empty: 0

tx fifo slip: 0

tx stuff: 0

rx fifo full: 0

rx fifo empty: 0

rx fifo slip: 0

line condition: good

noise margin: 3.5 > remote console

password: ******

>dsl clear errcntrs

>dsl show errcntrs

crc:0

losw:

 

0

tx fifo

full:

0

tx fifo

empty:

0

tx fifo

slip:

0

tx stuff:

0

rx fifo

full:

0

rx fifo

empty:

0

rx fifo

slip:

0

> logout

 

 

exiting

remote

console

>dsl set loopback rdl

>dsl set pattern 511e

>dsl show testmode

ber status: in progress

errors: 42

time: 12

>dsl set pattern off

>dsl set loopback off

>logout

password:

RocketLink Plug ‘n’ Play

The RocketLink Plug ‘n’ Play feature allows ISPs, carriers and PTTs to quickly upgrade the link speed for a customer without requiring a visit to re-configure the Customer Premise (CP) Model 3088. This feature also allows service providers to set up all of the configurations at the Central Office (via the ForeFront AIS system) before installing the stand alone units, saving time spent configuring or re-configuring DIP switches.

Note RocketLink Plug ’n’ Play is only available when using a ForeFront Model 3096RC running software release 1.5.7 or later. Since the 3096RC is CO, the RocketLink must be CP, which is the default.

The RocketLink Plug ‘n’ Play feature allows the user to configure the CP unit via the ForeFront Model 3096RC at the Central Office (CO). The stand alone unit at the Customer Premise (CP) site will automati- cally configure itself to the DTE rate (Bandwidth Allocation) defined at the Model 3096RC. Other configura- tion parameters may likewise be modified from their default setting.

Follow the instructions below to activate RocketLink Plug ‘n’ Play between CO (Model 3096RC and CP (Model 3088) units:

Set the Model 3096RC (CO) to either Internal or External clocking mode as defined by the application.

Introduction

39

Image 39
Contents Shdsl NTU with fixed serial interface Mailsupport@patton.com Summary Table of Contents Table of Contents RocketLink-G installation Software Upgrade Factory default values List of Figures List of Tables About this guide AudienceStructure Impaired functioning PrecautionsSafety when working with electricity Convention Meaning Typographical conventions used in this documentGeneral observations General conventionsGeneral information Chapter contentsFeatures RocketLink-G 3088 overviewSerial interface types External AC universal power supply Power input connectorExternal 48 VDC power supply Configuration Software CLI configuration Hardware DIP-switch configurationIntroduction E1-CRC Parameter Description Possible ValuesAMI 3088 K/T Models Configuring the DIP switchesDIP switch settings System reset modeSoftware upgrades Configuration reset to factory defaultsPosition Function S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 Data Rate kbps 2368 S2-3 Annex A/B Models 3088/CA and D S2-4 through S2-5 Clock Mode Models 3088/CA and DS1-8 TX Clock RocketLink-G models 3088/CA and 3088/D S2-2 Line Probe Models 3088/CA and DS2-6 Setting S2-6 DTE Loops RocketLink-G models 3088/CA onlyCPE-Side Modem CO-Side Modem Model 3088/K and 3088/T S1 DIP-Switch Functions 128 S2-3 Annex A/B Models 3088/K and 3088/T S2-4 through S2-5 Clock Mode Models 3088/K and 3088/TS1-7 and S1-8 Line Build Out Models 3088/K and 3088/T S2-2 Line Code Models 3088/K and 3088/TS2-6 S2-7 S2-8 Line Type S2-6 through S2-8 Line Type Models 3088/K and 3088/TConsole ReservedConfiguration DSL Line Condition Good or Poor Help Commands System Configuration Commands System Status CommandsDSL Configuration Commands Startup Delay Interval Interval totint DSL Status CommandDSL Clear Errcntrs Command T1/E1 Configuration CommandsT1/E1 Status Commands Example Command Line Interface SessionRemote Console RocketLink Plug ‘n’ Play Typical RocketLink Plug ‘n’ Play Application RocketLink-G installation Connecting the twisted pair interface InstallationConnecting the Model 3088/CA V.35 serial interface Connecting the Model 3088/CA V.35 to a DTE deviceConnecting the Model 3088/CA V.35 to a DCE device Connecting the Model 3088/D X.21 to a DCE or DTE device Connecting the Model 3088/D X.21 serial interfaceOpening the Case Connecting the Model 3088/D to X.21 DTE or DCEConnecting the Model 3088/K to an E1 Network Connecting the Model 3088/K serial interfaceConnect twisted pair 120 ohm to E1 network Connecting dual coaxial cable 75 ohm to E1 networkConnect Twisted Pair 100 ohm to T1 Network Connecting the Model 3088/T T1 serial interfaceExternal AC universal power supply Connecting powerTo Power Supply Jack DC PowerOperation DSL Green Power-upPower Green LED status monitorsTest modes Term Green Models C and DTM/ER Red LOS Red Models K and TPatterns LoopbacksRemote console operation Establishing a Remote Console Session How to ConnectLog in to 3088 Near End How to DisconnectRemote control session with LAL diagram Differences in Local and Remote Control Session BehaviorRemote console operation Software Upgrade Software Upgrade Reset configuration to factory defaults Reset configuration to factory defaults Contacting Patton for assistance Warranty coverage Contact informationPatton support headquarters in the USA RMA numbers Out-of-warranty serviceReturns for credit Return for credit policyAppendix a Compliance information Pstn Regulatory SafetyCompliance FCC Part 68 Acta StatementRadio and TV Interference FCC Part Industry Canada NoticeCE Declaration of Conformity Authorized European Representative Appendix B Specifications DTE rate Serial connectorDiagnostics Clocking modesConfiguration Power and power supply specificationsTerm Green Line interface Transmission lineLine coding Line rates DSL lineAppendix C Factory default values Parameter Default value Factory default values for software-configurable parametersB8ZS Appendix D Factory replacement parts and accessories Model # Description Factory replacement parts and accessoriesAppendix E Interface pinouts T1/E1 interface Pin # SignalRJ-11 non-shielded DSL port InterfaceRS-232 console interface pin assignments Sub-15 female connector DTE/DCE orientation

3088 Series specifications

The Patton Electronics 3088 Series is a robust solution tailored for businesses seeking reliable and efficient data connectivity. This series encompasses a range of devices designed to meet the growing demands of modern networking, particularly in environments that require resilient and secure communications.

One of the standout features of the 3088 Series is its versatile connectivity options. The devices support multiple interfaces, including Ethernet and serial connections, allowing for easy integration into existing infrastructures. This flexibility enables organizations to transition smoothly from outdated systems to state-of-the-art technology without extensive reconfiguration.

The 3088 Series also employs advanced protocols to ensure data integrity and security. Mechanisms such as error correction and data encryption are built into the architecture, safeguarding sensitive information from potential breaches. This is particularly important for industries that handle private data, such as healthcare or finance, where compliance with regulations is critical.

In addition to its connectivity features, the 3088 Series prioritizes ease of use and management. Each device is designed with user-friendly interfaces that simplify configuration and monitoring tasks. Comprehensive management options allow network administrators to efficiently track performance, modify settings, and troubleshoot issues remotely, thereby reducing downtime and maintaining productivity.

Furthermore, the 3088 Series emphasizes durability and reliability, making it suitable for demanding applications. Built using high-quality materials, these devices are engineered to withstand environmental stresses, making them ideal for industrial and outdoor deployments. This resilience contributes to lower maintenance costs and longer lifecycle.

The series is also designed with scalability in mind. As businesses grow and their networking needs evolve, the 3088 Series can adapt accordingly. This feature ensures that organizations can expand their capabilities without completely overhauling their systems, providing a cost-effective long-term solution.

Overall, the Patton Electronics 3088 Series stands out as a powerful and flexible platform for data communications. Its combination of versatile connectivity, high-level security features, ease of management, durability, and scalability render it an ideal choice for organizations looking to future-proof their networking infrastructures. As businesses continue to evolve in a digitally driven landscape, the 3088 Series provides a reliable backbone to support their communication needs.