Patton electronic 3088 Series Transmission line, Line coding, Line rates DSL line, Line interface

Page 74

Model 3088 Series User Manual

B • Specifications

 

 

External 48 VDC power supply

The external DC adaptor shall be a listed limited power source that incorporates a disconnect device and shall be positioned within easy reach of the operator. The interconnecting cables

CAUTION shall be rated for the proper voltage, current, anticipated tem- perature, flammability, and mechanical serviceability

Input

-Rated voltage: 36–60 VDC

-Rated current: 0.25 A DC

Output

-Rated voltage: 5 VDC ± 5%, 5W

-Rated current: 1 A DC

-6-inch cable terminated with 2.5 mm barrel plug, center positive

Isolation: 500 VDC

Environment: 0–40°C; 5–95% relative humidity, non-condensing

Transmission line

Single Twisted Pair

Line coding

TC-PAM (Trellis Coded Pulse Amplitude Modulation)

Line rates (DSL line)

All nx64 rates from 64 kbps up to 4.6 Mbps

Line interface

Transformer coupled, 2500 VRMS isolation

G.SHDSL physical connection

RJ-45, 2-wire polarity insensitive pins 4 and 5

Environment

Operating temp: 32–122°F (0–50°C)

Humidity: 5–95% non-condensing

Altitude: 0–15,000 feet (0–4,600 meters)

Transmission line

74

Image 74
Contents Shdsl NTU with fixed serial interface Mailsupport@patton.com Summary Table of Contents Table of Contents RocketLink-G installation Software Upgrade Factory default values List of Figures List of Tables Structure About this guideAudience Precautions Impaired functioningSafety when working with electricity General conventions Typographical conventions used in this documentGeneral observations Convention MeaningChapter contents General informationSerial interface types FeaturesRocketLink-G 3088 overview Power input connector External AC universal power supplyExternal 48 VDC power supply Configuration Introduction Software CLI configurationHardware DIP-switch configuration Parameter Description Possible Values E1-CRCAMI Configuring the DIP switches 3088 K/T ModelsConfiguration reset to factory defaults System reset modeSoftware upgrades DIP switch settingsPosition Function S1-1 S1-2 S1-3 S1-4 S1-5 S1-6 S1-7 Data Rate kbps 2368 S2-2 Line Probe Models 3088/CA and D S2-4 through S2-5 Clock Mode Models 3088/CA and DS1-8 TX Clock RocketLink-G models 3088/CA and 3088/D S2-3 Annex A/B Models 3088/CA and DCPE-Side Modem CO-Side Modem S2-6 SettingS2-6 DTE Loops RocketLink-G models 3088/CA only Model 3088/K and 3088/T S1 DIP-Switch Functions 128 S2-2 Line Code Models 3088/K and 3088/T S2-4 through S2-5 Clock Mode Models 3088/K and 3088/TS1-7 and S1-8 Line Build Out Models 3088/K and 3088/T S2-3 Annex A/B Models 3088/K and 3088/TReserved S2-6 through S2-8 Line Type Models 3088/K and 3088/TConsole S2-6 S2-7 S2-8 Line TypeConfiguration DSL Line Condition Good or Poor Help Commands DSL Configuration Commands System Configuration CommandsSystem Status Commands T1/E1 Configuration Commands DSL Status CommandDSL Clear Errcntrs Command Startup Delay Interval Interval totintRemote Console T1/E1 Status CommandsExample Command Line Interface Session RocketLink Plug ‘n’ Play Typical RocketLink Plug ‘n’ Play Application RocketLink-G installation Installation Connecting the twisted pair interfaceConnecting the Model 3088/CA V.35 to a DCE device Connecting the Model 3088/CA V.35 serial interfaceConnecting the Model 3088/CA V.35 to a DTE device Connecting the Model 3088/D X.21 serial interface Connecting the Model 3088/D X.21 to a DCE or DTE deviceConnecting the Model 3088/D to X.21 DTE or DCE Opening the CaseConnecting the Model 3088/K serial interface Connecting the Model 3088/K to an E1 NetworkConnecting dual coaxial cable 75 ohm to E1 network Connect twisted pair 120 ohm to E1 networkConnecting the Model 3088/T T1 serial interface Connect Twisted Pair 100 ohm to T1 NetworkConnecting power External AC universal power supplyDC Power To Power Supply JackOperation LED status monitors Power-upPower Green DSL GreenLOS Red Models K and T Term Green Models C and DTM/ER Red Test modesLoopbacks PatternsRemote console operation How to Connect Establishing a Remote Console SessionHow to Disconnect Log in to 3088 Near EndDifferences in Local and Remote Control Session Behavior Remote control session with LAL diagramRemote console operation Software Upgrade Software Upgrade Reset configuration to factory defaults Reset configuration to factory defaults Contacting Patton for assistance Patton support headquarters in the USA Warranty coverageContact information Return for credit policy Out-of-warranty serviceReturns for credit RMA numbersAppendix a Compliance information FCC Part 68 Acta Statement SafetyCompliance Pstn RegulatoryCE Declaration of Conformity Radio and TV Interference FCC PartIndustry Canada Notice Authorized European Representative Appendix B Specifications Clocking modes Serial connectorDiagnostics DTE rateTerm Green ConfigurationPower and power supply specifications Line rates DSL line Transmission lineLine coding Line interfaceAppendix C Factory default values Factory default values for software-configurable parameters Parameter Default valueB8ZS Appendix D Factory replacement parts and accessories Factory replacement parts and accessories Model # DescriptionAppendix E Interface pinouts Interface Pin # SignalRJ-11 non-shielded DSL port T1/E1 interfaceSub-15 female connector DTE/DCE orientation RS-232 console interface pin assignments

3088 Series specifications

The Patton Electronics 3088 Series is a robust solution tailored for businesses seeking reliable and efficient data connectivity. This series encompasses a range of devices designed to meet the growing demands of modern networking, particularly in environments that require resilient and secure communications.

One of the standout features of the 3088 Series is its versatile connectivity options. The devices support multiple interfaces, including Ethernet and serial connections, allowing for easy integration into existing infrastructures. This flexibility enables organizations to transition smoothly from outdated systems to state-of-the-art technology without extensive reconfiguration.

The 3088 Series also employs advanced protocols to ensure data integrity and security. Mechanisms such as error correction and data encryption are built into the architecture, safeguarding sensitive information from potential breaches. This is particularly important for industries that handle private data, such as healthcare or finance, where compliance with regulations is critical.

In addition to its connectivity features, the 3088 Series prioritizes ease of use and management. Each device is designed with user-friendly interfaces that simplify configuration and monitoring tasks. Comprehensive management options allow network administrators to efficiently track performance, modify settings, and troubleshoot issues remotely, thereby reducing downtime and maintaining productivity.

Furthermore, the 3088 Series emphasizes durability and reliability, making it suitable for demanding applications. Built using high-quality materials, these devices are engineered to withstand environmental stresses, making them ideal for industrial and outdoor deployments. This resilience contributes to lower maintenance costs and longer lifecycle.

The series is also designed with scalability in mind. As businesses grow and their networking needs evolve, the 3088 Series can adapt accordingly. This feature ensures that organizations can expand their capabilities without completely overhauling their systems, providing a cost-effective long-term solution.

Overall, the Patton Electronics 3088 Series stands out as a powerful and flexible platform for data communications. Its combination of versatile connectivity, high-level security features, ease of management, durability, and scalability render it an ideal choice for organizations looking to future-proof their networking infrastructures. As businesses continue to evolve in a digitally driven landscape, the 3088 Series provides a reliable backbone to support their communication needs.